The VOLTCRAFT VC292 is a robust and reliable digital multimeter designed for precise electrical measurements. It features a 6000-count display and is rated for CAT III 600V applications, making it suitable for a wide range of electrical testing in residential, commercial, and light industrial environments. This manual provides essential information for the safe and effective use, setup, operation, and maintenance of your VC292 multimeter.

VOLTCRAFT VC292 Digital Multimeter front view with display showing 5999 counts

Mufananidzo 1.1: Mberi view of the VOLTCRAFT VC292 Digital Multimeter, displaying its large digital readout and rotary function dial.

2. Safety Information

Always adhere to the following safety precautions to prevent personal injury and damage to the multimeter or equipment under test. This device complies with CAT III 600V safety standards, indicating its suitability for measurements in building installations.

3. Zvigadzirwa zveChigadzirwa

The VOLTCRAFT VC292 Digital Multimeter is equipped with a range of features to facilitate accurate and convenient measurements:

4. Package Zviri mukati

Please check the package contents upon unpacking to ensure all items are present and undamaged:

5. Setup

5.1. Kuiswa kwebhatiri

The VOLTCRAFT VC292 is powered by batteries. Ensure they are correctly installed before first use.

  1. Dzima multimeter uye bvisa chero bvunzo dzinotungamira.
  2. Tsvaga mukamuri yebhatiri kuseri kwemudziyo.
  3. Shandisa screwdriver kuvhura chivharo chebhatiri.
  4. Insert 3x 1.5V AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Tsiva chivharo chekamuri yebhatiri uye chengetedza nescuru.
Back view of VOLTCRAFT VC292 Digital Multimeter showing the battery compartment

Mufananidzo 5.1: Kumashure view of the multimeter, highlighting the battery compartment and warning label.

5.2. Kubatanidza Test Leads

Kubatana kwakaringana kweyedzo yekutungamira kwakakosha kune kwakaringana uye kwakachengeteka kuyerwa.

VOLTCRAFT VC292 Digital Multimeter with test leads connected and kickstand extended

Figure 5.2: The multimeter with test leads connected, demonstrating the kickstand for convenient viewing.

6. Operating Instructions

6.1. Kuvhura / Kudzima

Rotate the central function dial from the "OFF" position to any desired measurement function to turn on the multimeter. To turn off, rotate the dial back to the "OFF" position.

6.2. Basa Kusarudzwa

The large rotary dial is used to select the desired measurement function. Press the "SEL" button to cycle through sub-functions within a single dial position (e.g., AC/DC voltage, kuramba/kuenderera mberi/diode).

6.3. Measurement Modes

Below are common measurement modes and their applications:

Yakatenderedzwa kubva kumusoro kusvika pasi view of VOLTCRAFT VC292 Digital Multimeter showing the display and rotary dial

Mufananidzo 6.1: Angled view of the multimeter, illustrating the clear display and the main function selector dial.

7. Kuchengeta

7.1. Kuchenesa

Pukuta nyaya yacho neadamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and leads are disconnected before cleaning.

7.2. Kutsiviwa kwebhatiri

When the battery indicator appears on the display, replace the batteries as described in Section 5.1. Use only 3x 1.5V AAA batteries.

7.3. Fuse Replacement

If the multimeter fails to measure current, the fuse may be blown. Refer to the specifications for the correct fuse type and rating. Fuse replacement typically involves opening the battery compartment or a separate fuse compartment. Always replace with a fuse of the identical type and rating.

7.4. Kuchengeta

If the multimeter is not used for an extended period, remove the batteries to prevent leakage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
Hapana kuratidza kana dim kuratidzaDead or low batteries; incorrect battery polarity.Replace batteries; check battery orientation.
No current measurementBlown fuse; incorrect test lead connection; incorrect function selected.Replace fuse; ensure leads are in correct current jacks; select appropriate current range.
"OL" (Overload) inoratidzwaInput value exceeds selected range; open circuit (for resistance/continuity).Select a higher range (if not auto-ranging); check circuit for breaks.
Kurava kusina kururamaPoor test lead contact; external interference; low battery.Ensure firm contact; move away from strong electromagnetic fields; replace batteries.

9. Zvinotsanangurwa

ParameterValue
Model NumberVC-12884315
BrandVOLTCRAFT
Display6000 Counts, Digital
Safety RatingCAT III 600V
Simba SourceBattery Powered (3x 1.5V AAA)
Dimensions (L x W x H)190 x 90 x 43 mm (inenge 4.3 x 9 x 19 cm)
Kurema350 magiramu
FeaturesAuto-ranging, Flashlight, Display Illumination, AC/DC Current, LoZ, NCV

10. Warranty uye Tsigiro

VOLTCRAFT products are designed for durability and reliability. This product comes with a 1-year availability of spare parts within the EU, ensuring long-term support for your device.