1. Ruzivo Rwakakosha Chekuchengetedza
Ndapota verengai uye nzwisisai yambiro dzese dzekuchengetedza uye mirairo yekushandisa musati mashandisa chishandiso ichi. Kukundikana kutevedzera mirairo iyi kunogona kukonzera kuvhunduka kwemagetsi, moto, kana kukuvara kwakanyanya.
- Always ensure the meter is in good working condition before use. Inspect the test leads for any damage.
- Usashandise voltage or current that exceeds the maximum rated values specified for the meter.
- Exercise extreme caution when working with live circuits. High voltages can cause severe injury or death.
- Usashandise mita kana ichiita seyakakuvadzwa kana kana chivharo chebhatiri chisina kuvharwa zvakanaka.
- Use the correct function and range for each measurement.
- Keep fingers behind the finger guards on the test leads during measurements.
- Tsiva mabhatiri nekukurumidza kana chiratidzo chebhatiri chakaderera chaonekwa kuti uve nechokwadi chekuverenga chaiko.
2. Package Zviri mukati
Tarisa kuti zvinhu zvese zvakanyorwa pazasi zvinosanganisirwa mupakeji yako. Kana chero zvinhu zvisipo kana kukuvadzwa, ndapota taura neVEVOR rutsigiro rwevatengi.
- 1 x VEVOR EM4370 Digital Clamp Meter
- 1 x Pair of Test Leads (Stylus)
- 1 x K-type Thermocouple Probe
- 3 x AAA Batteries (1.5V)
- 1 x Kuchengeta Bhegi
- 1 x Chinyorwa cheMushandisi

Image: The VEVOR EM4370 Digital Clamp Meter shown with its test leads, K-type thermocouple probe, AAA batteries, storage bag, and user manual. Product dimensions are also indicated.
3. Chigadzirwa Pamusoroview
The VEVOR EM4370 is a True RMS digital clamp meter designed for accurate and reliable electrical measurements. It features a robust design and a clear LCD display.
3.1 Zvikamu
- Clamp Rushaya: Inoshandiswa pakuyera magetsi eAC/DC asingabatanidzi simba.
- Sensor yeNCV: Isiri-Yekubatanidza Voltage detection area.
- Basa Dial: Selects measurement modes.
- Chiratidziro cheLCD: Inoratidza kuverenga kwekuyerwa uye zviratidzo.
- Input Jacks: For connecting test leads (COM, VΩHzCAPTEMP).
- Mabhatani: MAX/MIN, SEL/FUNC, HOLD/LIGHT.
- Tochi: Integrated LED for illuminating dark work areas.

Mufananidzo: Mberi view of the VEVOR EM4370 Digital Clamp Meter, showing the clamp jaw, display, function dial, and buttons.

Mufananidzo: Yakadzama view of the function dial on the VEVOR EM4370, highlighting settings for current (60A, 600A), temperature, resistance, frequency/duty cycle, voltage, and NCV.
4. Setup
4.1 Kuiswa kwebhatiri
- Iva nechokwadi chekuti mita yadzimwa.
- Tsvaga nzvimbo yebhatiri kuseri kwemamita.
- Shandisa screwdriver kuvhura chivharo chebhatiri.
- Insert three (3) AAA 1.5V batteries, observing the correct polarity (+/-).
- Tsiva chivharo chekamuri yebhatiri uye chengetedza nescuru.
The meter will display a low battery indicator when the batteries need replacement.
5. Operating Instructions
This section details how to perform various measurements using the VEVOR EM4370 Digital Clamp Meter.
5.1 Basa Sarudzo
Rotate the function dial to select the desired measurement mode. Use the 'SEL/FUNC' button to toggle between different sub-functions within a mode (e.g., AC/DC voltage, Diode/Continuity).
5.2 AC/DC Chiyero Chazvino (Clamp)
- Turn the function dial to the '60A' or '600A' AC/DC current range.
- Dzvanya clamp trigger to open the clamp shaya.
- Enclose only one conductor (wire) within the clamp Iva nechokwadi chekuti shaya yakavharwa zvizere.
- Verenga kukosha kwazvino paLCD kuratidza.

Image: The VEVOR EM4370 clamp meter in use, with its jaw clamped around a single electrical wire to measure current.
5.3 AC/DC Voltage Kuyera
- Connect the red test lead to the 'VΩHzCAPTEMP' jack and the black test lead to the 'COM' jack.
- Turn the function dial to the 'V' (Voltage) range. Use the 'SEL/FUNC' button to select AC or DC voltage.
- Bata ma probes ekuyedza kusvika panzvimbo dzedunhu panowanikwa voltage inofanira kuyerwa.
- Verenga bhukutage kukosha pane LCD kuratidza.
5.4 Resistance Kuyera
- Batanidza malead ekuyedza seaya evoltage chiyero.
- Turn the function dial to the 'Ω' (Resistance) range.
- Ensure the circuit or component under test is de-energized before measuring resistance.
- Touch the test probes across the component.
- Verenga kukosha kwekupikisa pane LCD kuratidza.
5.5 Vasina-Kubata Voltage (NCV) Kuonekwa
- Turn the function dial to the 'NCV' position.
- Move the NCV sensor (top part of the clamp jaw) close to the conductor or outlet.
- The meter will beep and the NCV indicator light will flash when AC voltage is detected. The frequency of beeps and flashes increases with stronger voltage.

Image: The VEVOR EM4370 clamp meter detecting non-contact voltage near an electrical outlet, indicated by a visual alert on the meter's display.
5.6 Kuyera Kwekupisa
- Turn the function dial to the 'TEMP' position.
- Connect the K-type thermocouple probe to the input jacks, observing polarity.
- Place the tip of the thermocouple probe on or near the object whose temperature is to be measured.
- Read the temperature value on the LCD display. Use the 'SEL/FUNC' button to switch between Celsius (°C) and Fahrenheit (°F).

Image: The VEVOR EM4370 clamp meter displaying a temperature reading, with examples of its application in measuring temperatures of electrical appliances, liquids, gases, and in greenhouses.
5.7 Mamwe Mabasa
- Chokwadi RMS: The meter features True RMS detection for accurate measurements of non-sinusoidal AC waveforms.
- Data Hold: Press the 'HOLD/LIGHT' button briefly to freeze the current reading on the display. Press again to release.
- Backlight & Flashlight: Press and hold the 'HOLD/LIGHT' button to turn on/off the display backlight and the integrated flashlight.
- MAX/MIN Measurement: Press the 'MAX/MIN' button to record the maximum and minimum values during a measurement session.
- Capacitance: Select the 'CAP' range on the dial. Ensure capacitors are discharged before testing.
- Frequency/Duty Cycle: Select the 'Hz%' range on the dial.
- Diode Test & Continuity: Select the 'Diode/Continuity' range. Use 'SEL/FUNC' to switch between modes. Continuity test will beep if resistance is below a certain threshold.
- Smart Sleep Mode: The meter automatically powers off after approximately 15 minutes of inactivity to conserve battery life.

Image: The VEVOR EM4370 clamp meter display showing a True RMS reading, emphasizing its accuracy feature.

Image: The VEVOR EM4370 clamp meter demonstrating its LED backlit display for easy reading in low light, an integrated flashlight, and the automatic sleep mode function for energy saving.
6. Kuchengeta
6.1 Kuchenesa
Pukuta mita yacho neadamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is dry before storage or use.
6.2 Kutsiviwa kwebhatiri
Refer to Section 4.1 for battery installation instructions. Replace batteries promptly when the low battery indicator appears to maintain measurement accuracy.
6.3 Kuchengeta
If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in its storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Kugadzirisa matambudziko
If you encounter issues with your VEVOR EM4370, refer to the following common problems and solutions:
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Meter haina simba | Mabhatiri akafa kana kuti akaiswa zvisirizvo | Tarisa bhatiri polarity; kutsiva mabhatiri. |
| Kurava kusina kururama | Low battery; incorrect function/range; external interference | Replace batteries; select correct function/range; move away from strong electromagnetic fields. |
| Hapana kuonekwa kweNCV | Hapana AC voltage present; NCV sensor not close enough | Ongorora voltage presence with test leads; ensure sensor is near the live conductor. |
| Display shows 'OL' | Overload (measurement exceeds range) | Sarudza nzvimbo yakakwirira kana kuti iva nechokwadi chekuti chiyero chakayerwa chiri mukati memiganhu yemita. |
Kana dambudziko rikaramba riripo mushure mekuyedza mhinduro idzi, ndapota taura neVEVOR tsigiro yemutengi kuti uwane rumwe rubatsiro.
8. Zvinotsanangurwa
Detailed technical specifications for the VEVOR EM4370 Digital Clamp Meter.
| Parameter | Value |
|---|---|
| Model | EM4370 |
| Max. Display Count | 5999 (up to 9999 for some functions) |
| DC Voltage Range | 600mV / 6V / 60V / 600V |
| AC Voltage Range | 6V / 60V / 600V |
| DC Range Razvino | 60A / 600A |
| AC Yazvino Range | 60A / 600A |
| Resistance Range | 600Ω / 6kΩ / 60kΩ / 600kΩ / 6MΩ / 60MΩ |
| Temperature Range | -20 kusvika 1000 ℃ / -4 kusvika 1832 ℉ |
| Frequency Range | 9.999Hz / 99.99Hz / 999.9Hz / 9.99kHz / 99.99kHz / 999.9kHz / 9.999MHz |
| Capacitance Range | 6nF / 60nF / 600nF / 6μF / 60μF / 600μF / 6mF / 60mF |
| Duty Cycle | 5% - 95% |
| Chiyero Chakarurama | +/-0.5% (typical) |
| Mabasa | Diode Test, Continuity Test, Data Retention, NCV, Relative Value, Max./Min. Value, True RMS |
| Simba Source | 3 x AAA 1.5V Mabhatiri |
| Zviyero zveChigadzirwa (L x W x H) | 8.5 x 2.8 x 1.7 mukati (21.59 x 7.11 x 4.32 cm) |
| Item Weight | 454 g (1 lb) |
| Certifications | CE, FCC |
9. Warranty uye Tsigiro
VEVOR zvigadzirwa zvakagadzirirwa kusimba uye kuita. Kuti uwane ruzivo rwewaranti kana rutsigiro rwehunyanzvi, ndapota tarisa kune waranti kadhi inosanganisirwa nechigadzirwa chako kana shanyira yepamutemo VEVOR. website. You can also contact VEVOR customer service directly for assistance with product operation, maintenance, or troubleshooting.
VEVOR Official Websaiti: www.vevor.com





