Apera Instruments AI103G

Apera Instruments GroStar Series GS3 EC/ppm Pen Tester Kit (AI103G) User Manual

Model: AI103G

1. Nhanganyaya

This manual provides detailed instructions for the Apera Instruments GroStar Series GS3 EC/ppm Pen Tester Kit (AI103G). This lab-grade conductivity meter is designed for accurate measurement of EC (Electrical Conductivity), 500ppm, and 700ppm, along with temperature, making it suitable for hydroponics and general water quality testing. The device features a replaceable titanium conductivity sensor and a user-friendly interface.

2. Chigadzirwa Pamusoroview

The GroStar Series GS3 EC/ppm Pen Tester is engineered for reliability and ease of use. Key features include:

  • Measures conductivity (EC), 500ppm, 700ppm, and temperature.
  • Replaceable titanium sensor for high accuracy in the 0 to 10 EC range.
  • Backlit HD screen for clear readings.
  • Grower-friendly calibration workflow with a calibration reminder function.
Apera Instruments GroStar Series GS3 EC/ppm Pen Tester

Figure 1: Apera Instruments GroStar Series GS3 EC/ppm Pen Tester.

Close-up of the titanium alloy sensor

Mufananidzo 2: Pedyo-kumusoro view of the durable titanium alloy sensor for conductivity measurements.

GroStar GS3 Pen Tester in water

Figure 3: The GroStar GS3 Pen Tester demonstrating its water resistance during use.

3. Setup

Before first use, ensure all components are present and the device is ready for operation.

3.1 Chii chiri muBhokisi

  • Apera Instruments GroStar Series GS3 EC/ppm Pen Tester (Gen II)
  • 2.77 EC Calibration Solution
  • Lanyard
  • Mabhatiri mana eAAA (akaiswa kare kana kuti akaiswa oga)
Contents of the Apera Instruments GroStar Series GS3 EC/ppm Pen Tester Kit

Figure 4: The complete kit contents, including the tester, calibration solution, and lanyard.

3.2 Kuiswa kwebhatiri

The device requires 4 AAA batteries. If not pre-installed, open the battery compartment located at the top of the tester, insert the batteries according to the polarity indicators, and securely close the compartment.

3.3 Kugadzirira Kwekutanga

  1. Bvisa chivharo chekudzivirira kubva kune sensor.
  2. Rinse the sensor with distilled or deionized water.
  3. Gently shake off excess water.

4. Operating Instructions

4.1 Simba On/Kudzima

Press the SIMBA button to turn the tester on or off.

4.2 Kutora Chiyero

  1. Ensure the tester is clean and calibrated.
  2. Nyura iyo sensor mu sampmhinduro, ichiita kuti sensor inyudzwe zvizere.
  3. Stir gently and wait for the reading to stabilize on the display.
  4. The display will show EC/ppm and temperature readings.

4.3 Switching Measurement Modes (EC/ppm)

Press the MODE/UNITS button to cycle through EC, 500ppm, and 700ppm measurement modes.

Display showing EC, 500ppm, and 700ppm modes

Figure 5: The tester's display cycling through different measurement units.

4.4 Bata Basa

Press the BATA bhatani kuti uomese kuverenga kuripo pachiratidziro. Dzvanya zvakare kuti ubvise.

4.5 TruRead Display

The TruRead display provides MAX, AVG, and MIN readings, offering a comprehensive view of your measurements.

TruRead Display showing MAX, AVG, MIN readings

Figure 6: The TruRead display feature, showing maximum, average, and minimum recorded values.

5. Calibration

Regular calibration ensures accurate measurements. The GS3 features a grower-friendly calibration workflow and a reminder function.

5.1 Calibration Maitiro

  1. Batidza tester.
  2. Press the CAL bhatani rekupinda mu calibration mode.
  3. Immerse the sensor into the 2.77 EC calibration solution.
  4. The tester will automatically recognize the solution and calibrate. Wait for the stable reading and confirmation.
  5. Rinse the sensor with distilled water after calibration.
Display showing measurement, calibration, and error modes

Figure 7: Visual representation of the tester's display in measurement, calibration, and error states.

5.2 Calibration Reminder

The tester will automatically remind you when recalibration is due, ensuring consistent accuracy.

6. Kuchengeta

6.1 Kuchenesa Sensor

After each use, rinse the sensor thoroughly with distilled or deionized water to prevent residue buildup. Do not scrub the sensor vigorously.

6.2 Kuchengeta

Always replace the protective cap after use. For long-term storage, ensure the sensor is kept moist. Refer to the product packaging or Apera Instruments website for specific storage solution recommendations if applicable.

6.3 Kutsiva Sensor

The titanium EC sensor is replaceable. If the sensor performance degrades significantly or it becomes damaged, a new sensor can be purchased and easily installed by twisting off the old one and attaching the new one.

7. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
Kurava kusina kururamaSensor is dirty or dry; Calibration is outdated or incorrect; Damaged sensor.Clean the sensor; Recalibrate the tester; Replace the sensor if damaged.
Tester does not power onDead batteries; Incorrect battery installation.Tsiva mabhatiri; Tarisa polarity yebhatiri.
"CAL Er" error during calibrationIncorrect calibration solution; Contaminated solution; Sensor issue.Ensure correct 2.77 EC solution is used; Use fresh calibration solution; Clean or replace sensor.

8. Zvinotsanangurwa

  • Model Number: AI103G
  • Zviyero zvechigadzirwa: 7 x 1.5 x 1.3 inches
  • Kurema 4.69 ounces
  • Kunobva Simba: 4 AAA mabhatiri (akabatanidzwa)
  • Sensor Type: Replaceable Titanium EC Probe
  • Measurement Parameters: EC, 500ppm, 700ppm, Temperature
  • Zuva Rokutanga Kuwanikwa: Gunyana 28, 2022

9. Warranty uye Tsigiro

Apera Instruments products are backed by a manufacturer's warranty. For detailed warranty information, technical support, or to purchase replacement parts, please visit the official Apera Instruments websaiti kana kubata basa ravo revatengi zvakananga. Chengeta risiti yako yekutenga yezvichemo zvewaranti.

Mugadziri: Apera Instruments

Related Documents - AI103G

Preview Bhuku rekushandisa reApera GroStar GS2 Premium Soil pH Pen Tester | Kuongororwa kweIvhu Kwakarurama
Bhuku rekushandisa rakakwana reApera GroStar GS2 Premium Soil pH Pen Tester. Dzidza nezvekuyera, kuyera, kugadzirisa matambudziko, uye kugadzirisa kuti iongororwe pH yevhu nemazvo.
Preview Apera EC20 Pocket Conductivity Tester: Bhuku reMirayiridzo & Gwaro
Bhuku remirayiridzo rakakwana reApera EC20 Pocket Conductivity Tester. Dzidza nezvekugadzirisa, kugadzirisa, kuyerwa kwe conductivity, hunyanzvi hwehunyanzvi, uye ruzivo rwewarandi.
Preview Apera Instruments PC60 Premium 5-in-1 Tester User Manual
Comprehensive user manual for the Apera Instruments PC60 Premium 5-in-1 Tester, covering pH, Conductivity, TDS, Salinity, and Temperature measurements. Includes setup, calibration, operation, maintenance, and troubleshooting.
Preview EC850 Portable Conductivity Meter User Manual
User manual for the Apera EC850 portable conductivity meter, detailing its specifications, instrument description, conductivity measurement procedures, parameter settings, what's included, warranty information, and appendices.
Preview Apera Zvishandiso EC20 Pocket Conductivity Tester Instruction Manual
Chinyorwa chemushandisi cheApera Instruments EC20 Pocket Conductivity Tester, inovhara kuisirwa bhatiri, makiyipadhi mabasa, calibration, conductivity kuyerwa, tekinoroji yakatarwa, uye ruzivo rwewaranti.
Preview Apera EC1 Pocket Conductivity Tester Instruction Manual
Yakakwana yekuraira Chinyorwa cheiyo Apera EC1 Pocket Conductivity Tester, inodonongodza maitiro ayo, mashandiro, kuenzanisa, tekinoroji yakatarwa, uye ruzivo rwewaranti.