Beghelli 4340F

Beghelli 4340F 100 Lumen LED Emergency Lamp

User Manual

Nhanganyaya

Thank you for choosing the Beghelli 4340F 100 Lumen LED Emergency Lamp. This device is designed to provide reliable emergency lighting in various environments. Please read this manual carefully before installation and use to ensure proper function and safety.

Product Overview

The Beghelli 4340F is a compact and efficient LED emergency lamp, featuring a built-in battery for automatic operation during power outages. Its modern design and durable plastic construction make it suitable for both indoor and outdoor applications.

Chii chiri muBhokisi

  • Beghelli 4340F 100 Lumen LED Emergency Lamp
  • Mounting hardware
  • User Manual

Safety Information

  • Gara uchidzima magetsi usati waisa kana kugadzirisa.
  • Kuisa kunofanira kuitwa nenyanzvi yemagetsi inokwanisa zvichienderana nemitemo yemagetsi yemunharaunda.
  • Do not expose the unit to extreme temperatures or direct moisture unless specified for outdoor use.
  • Do not attempt to open or repair the unit yourself. Refer to qualified service personnel.
  • Ensure the mounting surface is stable and can support the weight of the lamp.

Setup uye Installation

The Beghelli 4340F emergency lamp is designed for wall-mounted installation, typically recessed into a standard electrical box. Follow these steps for proper setup:

1. Gadzirira Chikwata

Carefully remove the front cover of the emergency lamp to access the internal components. Connect the battery to the circuit board if it is not already connected. Ensure all connections are secure.

Beghelli 4340F LED Emergency Lamp with internal components visible, showing battery and circuit board.

Image: The Beghelli 4340F emergency lamp with its front cover removed, revealing the internal battery and circuit board. This view is essential for initial setup and battery connection.

2. Mounting the Base

Install the black recessed box (not included, but shown in video as a typical installation method) into the wall according to standard electrical practices. Ensure the box is securely fastened and flush with the wall surface.

3. Wiring

Connect the mains power supply (230V~50Hz) to the terminals on the circuit board. Refer to the wiring diagram provided with the product for specific connections. Ensure correct polarity and secure all wires.

4. Assemble the Lamp

Once the wiring is complete and tested, carefully place the lamp's internal assembly (with the battery and circuit board) into the white casing. Then, secure the white casing into the recessed box. Finally, attach the front cover to the white casing, ensuring it clicks firmly into place.

Video: This video demonstrates the assembly process of the Beghelli emergency lamp, including connecting the battery, placing the internal components into the casing, and securing the unit into a recessed box.

Video: This video illustrates the final steps of installing the emergency lamp into a recessed wall box, showing how the unit fits securely and the cover is attached.

Video: This video provides another perspective on the installation of the Beghelli emergency lamp, demonstrating the secure placement of the lamp into its housing.

Operating Instruction

The Beghelli 4340F emergency lamp operates automatically once properly installed and connected to the mains power supply.

  • Normal Operation: When mains power is present, the lamp's internal battery will charge. The lamp icharamba yakanyarara.
  • Emergency Operation: In the event of a power failure, the lamp will automatically switch on, providing 100 lumens of LED light from its built-in battery.
  • Nguva Yebhatiri: Iyo lamp is designed to provide illumination for a specified duration during an emergency. Refer to the specifications for battery autonomy.
  • Kuedza: It is recommended to periodically test the emergency lamp by temporarily cutting the mains power to ensure it functions correctly.

Maintenance

Regular maintenance ensures the longevity and reliability of your emergency lamp.

  • Kuchenesa: Chenesa kunze kwelamp nejira rakapfava, rakaoma. Usashandise zvinochenesa zvinogumbura kana zvinonyungudutsa.
  • Kutarisa Battery: The built-in battery has a limited lifespan. If the lamp's emergency duration significantly decreases, the battery may need replacement. This should be done by a qualified technician.
  • Kushanda Muedzo: Perform a monthly test by simulating a power outage to confirm the lamp activates and provides adequate light.
  • Visual Inspection: Nguva nenguva ongorora lamp kune chero zviratidzo zvekukuvadzwa kana kupera.

Kugadzirisa matambudziko

If you encounter issues with your Beghelli 4340F emergency lamp, tarisa matambudziko akajairika nemhinduro dzinotevera:

DambudzikoZvinogona KukonzeraSolution
Lamp does not turn on during power outage.No mains power; Battery not charged; Battery faulty; Internal wiring issue.Check mains power supply; Allow 24 hours for initial battery charge; Replace battery (qualified technician); Contact support.
Lamp inoramba iripo nguva dzose.Mains power not connected; Faulty charging circuit.Verify mains power connection; Contact support.
Reduced emergency lighting duration.Kuparara kwebhatiri.Replace battery (qualified technician).

Zvinotsanangurwa

FeatureDetail
BrandBeghelli
Model4340F
Product TypeLighting Fixture
Luminous Flux100 lumens
Bulb TypeLED
Simba SourceMains Powered (230V~50Hz) with Built-in Battery
Bhatiri TypePb 4V 3Ah (as per product label)
Energy Consumption Class (EU)125 lm/W
MaterialPlastiki
ColorChena
ShapeRectangular
Installation TypeKugadzika Madziro (Kwakadzoserwa)
Mashandisirwo AkanangaKunze
CertificationCE
Item Weight1 kg

Warranty uye Support

Beghelli products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the official Beghelli websaiti kana kubata muparidzi wenzvimbo yako. Chengeta risiti rako rekutenga seumboo hwekutenga.

Related Documents - 4340F

Preview F94001 - F94002 PianaLED Beghelli Praezisa Installation Guide
Installation instructions and warranty information for the Beghelli PianaLED F94001 and F94002 emergency lighting fixtures. Includes diagrams and multilingual warnings.
Preview Beghelli Completa LED TR Emergency Luminaire Installation and Technical Guide
Installation and technical guide for the Beghelli Completa LED TR emergency LED luminaire. Details IP ratings (IP40, IP42, IP66), wiring, model specifications, operation, and safety warnings.
Preview Beghelli Stile + TR RM Emergency Light Installation and User Manual
Comprehensive guide for installing and operating the Beghelli Stile + TR RM emergency lighting luminaire. Includes technical specifications, wiring diagrams, and safety warnings.
Preview Beghelli Giornale - March-June 2020 Edition
This edition of Beghelli Giornale features new products and offers from the Beghelli Group, including the Cloud Beghelli platform for managing lighting and emergency lighting systems, the Archieco emergency lighting line, and various lighting fixtures like LED panels, floodlights, and strip LEDs.
Preview Beghelli Aestetica LED Emergency Luminaire Installation and Safety Guide
Comprehensive guide for the Beghelli Aestetica LED emergency luminaire, covering installation, wiring, LED indicators, technical specifications, and safety warnings. Includes model details and manufacturer information.
Preview Beghelli Micro Dot CT Emergency Lighting Installation and Settings Guide
Comprehensive guide for the Beghelli Micro Dot CT emergency light, covering installation, wiring, configuration, settings, and troubleshooting. Includes technical specifications and safety warnings.