1. Chigadzirwa Pamusoroview
The Senville AURA Series Mini Split Air Conditioner and Heat Pump is an energy-efficient climate control system designed for both cooling and heating. This 33000 BTU model (SENA-33HF-16) features inverter technology for optimal performance and is equipped with smart control capabilities.
Zvinokosha:
- Kushanda Kwesimba: Energy Star Certified, UL Listed, and AHRI Certified for reliable and efficient operation.
- Wide Operating Range: Provides dependable cooling and heating in extreme conditions, from -22°F (-30°C) to 122°F (50°C).
- Smart Kudzora: Compatible with Alexa for voice control and offers app-based control for remote operation and scheduling.
- Quiet Operation: Designed for low noise levels, enhancing indoor comfort.
- Inverter Technology: Advanced DC Inverter adjusts output to room needs, reducing energy waste and providing precise temperature control.
- Sisitimu Yakakwana: Includes an indoor air handler, outdoor condenser, 16ft line set, and communication wire.

Mufananidzo 1: Kupfuuraview of the Senville AURA Series Mini Split system, showing the indoor unit, outdoor unit, remote control, and connecting lines.
2. Safety Information
Please read all safety instructions carefully before installation and operation to prevent injury or damage. Keep this manual for future reference.
- Professional Installation Inodiwa: This unit requires professional installation by a qualified HVAC technician. Attempting DIY installation may void the warranty and pose safety risks.
- Kuchengetedzwa Kwemagetsi: Ensure the unit is connected to a dedicated 208-230V DC power supply with appropriate circuit protection. All electrical work must comply with local and national electrical codes.
- Refrigerant Handling: The system contains refrigerant. Only qualified personnel should handle refrigerant lines and connections. Improper handling can lead to leaks and environmental damage.
- Clearances: Chengetedza nzvimbo dzakakwana dzakatenderedza dzimba dzemukati nedzekunze kuti mweya upinde zvakanaka uye ugadziriswe.
- Vana uye Zvipfuwo: Chengetedza vana uye mhuka dzinovaraidza kure neyuniti panguva yekushanda nekugadzirisa.
- Kufefetedza Do not block air inlets or outlets on either unit.
3. Package Zviri mukati
Tarisa uone kuti zvese zviriko uye hazvina kukuvara pakuburitsa:
- Indoor Air Handler Unit
- Kunze Condenser Unit
- 16 Ft. Copper Line Set
- Communication Cable
- Remote Control
- WiFi Kit (for smart control functionality)
- Mushandisi Chinyorwa (gwaro iri)
4. Kuiswa uye Setup
Installation of the Senville AURA Series Mini Split system requires specialized tools and knowledge. It is mandatory for a qualified HVAC professional to perform the installation to ensure proper function, safety, and warranty validity.
4.1 Sarudzo yeSaiti
- Indoor Unit: Select a location that allows for even air distribution, away from direct sunlight or heat sources, and with sufficient wall strength to support the unit.
- Kunze Chikwata: Choose a well-ventilated area, free from obstructions, and on a stable, level surface. Ensure adequate clearance for airflow and maintenance.
4.2 Kubatanidzwa kweMagetsi
- The unit operates on 208-230V DC. A dedicated circuit is required.
- All wiring must be performed by a licensed electrician in accordance with local and national electrical codes.
- Iva nechokwadi chekugadzika kwakakodzera kudzivirira kuvhunduka kwemagetsi.
4.3 Refrigerant Line Set Connection
- The 16ft copper line set connects the indoor and outdoor units.
- Connections must be properly flared and torqued to prevent refrigerant leaks.
- A vacuum pump must be used to evacuate the line set before releasing refrigerant.
4.4 WiFi Kit Installation (for Smart Control)
The included WiFi kit enables smart control features. Refer to the separate WiFi kit installation guide for detailed instructions on connecting it to your home network and integrating with the Senville app or Alexa.

Figure 2: Illustration of smart control functionality, showing a user interacting with Alexa and a mobile app to manage the Senville AURA system. The Alexa Kit must be installed for this feature.
5. Operating Instructions
The Senville AURA Series can be operated using the included remote control or via the Senville mobile app and Alexa voice commands after WiFi kit installation.
5.1 Remote Control Kushanda
The remote control provides direct access to all functions. Point the remote control towards the indoor unit when making adjustments.
- Batidza/Kudzima: Dzvanya bhatani remagetsi kuti ubatidze kana kudzima unit.
- Sarudzo yeModhi: Use the mode button to cycle through operating modes:
- Kutonhora: Zvekutonhodza imba.
- Kupisa: Yekudziisa imba.
- Feni: Inotenderera mhepo isina kudziyisa kana kutonhora.
- Dry (Dehumidify): Inoderedza humidity mumba.
- Auto: Inosarudza otomatiki kutonhora kana kudziyisa zvichibva patembiricha yakatarwa.
- Kugadzirisa Tembiricha: Shandisa miseve yekukwira/kudzika kuti uise tembiricha yaunoda.
- Kumhanyisa kweFan: Adjust the fan speed (Low, Medium, High, Auto) to control airflow.
- Swing Basa: Activates or deactivates the automatic louver swing for even air distribution.
- Basa renguva: Gadza kuti mudziyo uvhure kana kudzima otomatiki panguva dzakatarwa.
- Nzira yekurara: Adjusts temperature and fan speed for comfortable sleep and energy saving.
5.2 Smart Control via App and Alexa
Once the WiFi kit is installed and configured, you can control your Senville AURA system remotely.
- Mobile App: Download the Senville app to your smartphone. The app allows you to power on/off, change modes, adjust temperature, set schedules, and monitor the unit from anywhere.
- Alexa Voice Control: Integrate your Senville unit with Amazon Alexa. Use voice commands such as "Alexa, set my mini split to cooling" or "Alexa, turn on the air conditioner" to control the system hands-free.
- Geolocation: Utilize the geolocation feature in the app to automatically adjust temperatures based on your proximity to home, optimizing energy use.
6. Kuchengeta
Regular maintenance ensures optimal performance and longevity of your Senville AURA system. Always turn off the power supply to the unit before performing any maintenance.
6.1 Mhepo Sefa Yekuchenesa
- The indoor unit's air filters should be cleaned every 2-4 weeks, or more frequently depending on usage and air quality.
- Vhura jira repamberi remuchina wemukati wobvisa mafirita nokungwarira.
- Wash filters with lukewarm water and a mild detergent, or vacuum them to remove dust.
- Bvumira mafirita kuti aome zvachose usati waisazve.
6.2 Indoor Unit Cleaning
- Pukuta kunze kwekamuri yemukati nekanyoro, damp jira. Usashandise makemikari ane hasha kana abrasive cleaners.
- Ensure the condensate drain is clear and free of blockages.
6.3 Kucheneswa kwePanze Unit
- Keep the area around the outdoor unit clear of debris, leaves, and snow to ensure proper airflow.
- Periodically clean the outdoor coil fins with a soft brush or water hose. Be careful not to bend the fins.
- For thorough cleaning and inspection, it is recommended to schedule annual professional maintenance.
7. Kugadzirisa matambudziko
Usati wabata rutsigiro rwevatengi, review zvinotevera zvinowanzoitika uye mhinduro:
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Unit haibatike. | Hapana magetsi; circuit breaker yagumburwa; mabhatiri eremote control akaderera. | Tarisa kubatana kwemagetsi; gadzirisa circuit breaker; chinja mabhatiri eremote control. |
| Kusakwana kutonhora/kudziyisa. | Dirty air filters; blocked outdoor unit; incorrect mode setting; temperature setting too high/low. | Clean air filters; clear obstructions from outdoor unit; select correct operating mode; adjust temperature setting. |
| Ruzha rusina kujairika kubva kuyuniti. | Loose parts; foreign objects; normal operating sounds (e.g., refrigerant flow, defrost cycle). | Inspect for loose components; remove any foreign objects. If noise persists or is abnormal, contact a professional. |
| Kubuda kwemvura kubva mukati meimba. | Blocked condensate drain; improper installation. | Check and clear condensate drain. If issue persists, professional inspection is required. |
| WiFi yekubatanidza nyaya. | Incorrect WiFi setup; weak signal; router issues. | Refer to WiFi kit instructions for setup; ensure strong WiFi signal; restart router. |
For issues not listed here or if troubleshooting steps do not resolve the problem, please contact Senville Customer Support.
8. Zvigadzirwa zveChigadzirwa
| Feature | Detail |
|---|---|
| Brand | Senville |
| Model Number | SENA-33HF-16 |
| Kutonhodza Simba | 33000 British Thermal Units (BTU) |
| Capacity | 2.75 Matani |
| Voltage | 220 Volts (DC) |
| Seasonal Energy Efficiency Ratio (SEER) | 19.5 |
| BEE Star Rating | Energy Star |
| Noise Level | 35 Decibels (Indoor Unit) |
| Zviyero zveChigadzirwa (Chikamu Chekunze) | 48 x 40 x 60 inches |
| Item Weight | 157 makirogiramu |
| Fomu Factor | Mini-Split |
| Special Feature | Alexa Yakagoneswa |
| Inosanganisirwa Zvikamu | 16 Ft. Copper Line, Communication Cable, Indoor Air Handler, Outdoor Condenser, Remote Control, WiFi Kit |
| Color | Chena |
| Kutanga Gore | 2023 |
9. Ruzivo rweWaranti
The Senville AURA Series Mini Split Air Conditioner Heat Pump comes with a limited warranty:
- Zvikamu Warranty: 5 years
- Compressor Warranty: 10 years
Yakakosha Warranty Conditions:
- Professional installation by a qualified technician is zvinodiwa kuti waranti ishande.
- The warranty covers parts replacement only and does not cover labor costs.
- Replacement parts are available for purchase outside of the warranty period.
- Failure to adhere to installation and maintenance guidelines may void the warranty.
10. Mutengi Tsigiro
For technical assistance, troubleshooting, or warranty inquiries, please contact Senville Customer Support:
- Rutsigiro rwerunhare: Speak directly with HVAC experts.
- 24/7 Live Chat: Get answers to your questions day or night.
- Refer to the official Senville webwebhusaiti yeruzivo rwekuonana nevamwe uye zvimwe zvinhu.





