This manual provides essential information for the safe and effective operation of your OWON CM2100 Digital AC/DC Clamp Meter. Please read this manual thoroughly before use and retain it for future reference. The CM2100 is a portable, true RMS clamp meter designed for measuring AC/DC current, AC/DC voltage, resistance, capacitance, diode, and non-contact voltage (NCV).
Safety Information
YAmbiro: Kuti udzivise kuvhunduka kwemagetsi kana kukuvara kwako, verenga uye unzwisise ruzivo rwese rwekuchengetedza usati washandisa chigadzirwa ichi.
- Gara uchiomerera kumakodhi ekuchengetedza emunharaunda uye enyika.
- Do not use the meter if it appears damaged or if the insulation is compromised.
- Usashandise zvinopfuura zvakatemerwa voltage, sezvakarongwa pamamita, pakati pematerminals kana pakati pechero terminal nepasi pasi.
- Shandisa kungwarira paunenge uchishanda nevoltages pamusoro pe30V AC RMS, 42V peak, kana 60V DC. Aya voltages inokonzeresa njodzi.
- Remove the test leads from the meter before opening the battery cover.
- Iva nechokwadi chekuti function switch iri panzvimbo chaiyo yekuyera kuri kuitwa.
- Usashandise mita yakatenderedza gasi rinoputika, mhute, kana huruva.
- Always use appropriate personal protective equipment (PPE).
Product Overview uye Zvikamu
Familiarize yourself with the various parts of your CM2100 clamp meter before operation.

Mufananidzo: Detailed diagram of the OWON CM2100 clamp meter, highlighting its key components such as the NCV sensor, pincher head trigger, function selection knob, DCA reset/BLE button, function selector, NCV light, LCD display, numerical lock/backlight switch, capacity/resistance/voltage/frequency/diode/ON-OFF input jack, and common-end jack. Dimensions are also indicated.
- Sensor yeNCV: Detects non-contact voltage.
- Pincher Head Trigger: Inovhura nekuvhara clamp shaya.
- Basa Sarudzo Knob: Rotates to select different measurement modes (e.g., V~, V=, A~, A=, Ω, NCV, VFC, Hz%).
- DCA Reset/BLE Button: Used for DC current zeroing and Bluetooth (BLE) activation on compatible models (CM2100B).
- Basa Rokusarudza: Toggles between specific functions within a mode (e.g., AC/DC voltage, resistance/capacitance).
- Chiedza cheNCV: Illuminates to indicate non-contact voltage kuona.
- Chiratidziro cheLCD: Inoratidza kuverengwa kwekuyera, mayuniti, uye zviratidzo.
- Numerical Lock/Backlight Switch: Locks the current reading (HOLD) and activates the display backlight.
- Input Jacks: Yekubatanidza bvunzo inotungamira yevoltage, kuramba, capacitance, diode, uye kuenderera kuyerwa.
- Common-End Jack: The negative (-) input for test leads.
Chii chiri muBhokisi
Upon opening the package, verify that all items listed below are present and undamaged.

Mufananidzo: Contents of the OWON CM2100 package, including the CM2100 clamp meter, a pair of multimeter test leads (red and black), a small bolt driver, a quick guide, and a soft carrying bag.
- OWON CM2100 Clamp Meter
- Mirayiridzo yeMultimeter Test Leads (Tsvuku neDema)
- Bolt Driver (for battery compartment)
- Kurumidza Kutungamira
- Soft Carrying Bag
Gadzirira
Kuiswa kweBattery
- Iva nechokwadi chekuti mita yadzimwa.
- Tsvaga nzvimbo yebhatiri kuseri kwemamita.
- Use the provided bolt driver to loosen the screw securing the battery cover.
- Bvisa chivharo chebhatiri.
- Insert the Lithium Metal battery (included) according to the polarity markings inside the compartment.
- Tsiva chivharo chebhatiri uye simbisa sikuruu.
Chekutanga Power On
Rotate the function selection knob from OFF to any measurement function to power on the meter. The LCD display will illuminate.
Operating Instruction
Basa Sarudzo
Rotate the central knob to select the desired measurement function. The meter features an automatic range for most measurements, simplifying operation.

Mufananidzo: Overview of the OWON CM2100's multiple measurement functions, including Resistance (Ω), NCV, VFC, HOLD, ON/OFF (continuity), LCD, Capacitance, Diode, Overload Protection, Low Battery Alert, Buzzing Prompt, and True RMS. It also highlights the 20000 counts, auto range, AC/DC voltage, and AC/DC current measurement capabilities.
Measurement Modes
- AC/DC Current Measurement (A~ / A=):
Rotate the knob to the 'A~' or 'A=' position. Press the trigger to open the clamp jaws and enclose a single conductor. Ensure the conductor is centered within the jaws for accurate readings. The display will show the current value. For DC current, press the DCA Reset button to zero the reading before measurement.
- AC / DC Voltage Measurement (V~ / V=):
Insert the red test lead into the VΩHz input jack and the black test lead into the COM jack. Rotate the knob to 'V~' for AC voltage kana 'V=' yeDC voltage. Connect the test leads in parallel to the circuit or component to be measured. The display will show the voltage value.
- Kuyerwa kweKuramba (Ω):
Insert test leads as for voltage. Rotate the knob to the 'Ω' position. Connect the test leads across the component. The display will show the resistance value in Ohms (Ω).
- Capacitance Measurement:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to capacitance mode (usually indicated by 'nF', 'µF'). Connect the test leads across the capacitor. The display will show the capacitance value.
- Diode Bvunzo:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to diode test mode (indicated by a diode symbol). Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltage kudonha
- Continuity Test:
Insert test leads as for voltage. Rotate the knob to the 'Ω' position and use the Function Selector button to cycle to continuity mode (indicated by a buzzer symbol). If the resistance is below a certain threshold, the buzzer will sound, indicating continuity.
- Isiri-Yekubatanidza Voltage (NCV) Kuonekwa:
Rotate the knob to the 'NCV' position. Bring the NCV sensor (top part of the clamp meter) close to an AC voltage source. The NCV light will illuminate, and an audible beep will sound, with increasing frequency as the meter gets closer to the voltage source.
- VFC (Variable Frequency Drive) Measurement:
Rotate the knob to the 'VFC' position. This mode is designed for measuring AC voltage and frequency of variable frequency drives, providing more stable readings in such environments.
- Frequency (Hz%) Measurement:
Rotate the knob to the 'Hz%' position. This mode measures the frequency of AC signals. Connect test leads as for voltage measurement. The display will show the frequency in Hertz (Hz).
Mamwe Mabasa
- BATA Basa: Press the HOLD button (often combined with backlight) to freeze the current reading on the display. Press again to release.
- Backlight: Press and hold the HOLD/Backlight button to activate the display backlight for better visibility in low-light conditions. Press and hold again to turn off.
- Chokwadi RMS: The CM2100 is a True RMS meter, meaning it accurately measures AC voltage and current for both sinusoidal and non-sinusoidal waveforms.
- Bluetooth Communication (CM2100B model only): If you have the CM2100B model, activate Bluetooth by pressing the BLE button. This allows remote data viewing and instrument control via a compatible smartphone application.

Mufananidzo: Examples of the OWON CM2100 clamp meter in use, demonstrating capacitance measurement for maintenance, NCV (Non-Contact Voltage) inductive measurement, circuit board resistance measurement, and diode measurement.
Maintenance
Kuchenesa
Pukuta mita yacho neadamp jira nesipo isina kunyorova. Usashandise zvinogumbura kana zvinonyungudutsa. Chengeta nzvimbo dzekupinda dzisina tsvina kana hunyoro.
Kutsiviwa kwebhatiri
When the low battery indicator appears on the display, replace the battery promptly to ensure accurate measurements. Refer to the "Battery Installation" section under Setup for instructions.
Storage
If the meter is not used for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Chiyero chemita hachibatidzi. | Bhatiri rafa kana kuti rakaiswa zvisirizvo. | Tarisa polarity yebhatiri kana kuti tsiva bhatiri. |
| Hapana kuverenga kana "OL" kunoratidzwa. | Overload, open circuit, or incorrect function selected. | Ensure the circuit is closed, select the correct function, or check if the measured value exceeds the meter's range. |
| Kurava kusina kururama. | Low battery, poor test lead connection, or external interference. | Replace battery, ensure secure connections, move away from strong electromagnetic fields. |
| NCV isiri kuona voltage. | Weak signal, incorrect distance, or meter malfunction. | Ensure the sensor is close to the AC source. Test with a known live circuit. |
Zvinotsanangurwa
| Parameter | Value |
|---|---|
| Brand | OWON |
| Model | CM2100 (QD-CM2100) |
| Chiyero Type | Ammeter, Voltmeter |
| Display Counts | 20000 Counts |
| Chokwadi RMS | Ehe |
| AC / DC Izvozvi | Kusvika ku100A |
| AC / DC Voltage | Kusvika ku600V |
| Mhinduro yeA AC Frequency | Kusvika ku1000Hz |
| Isiri-Yekubatanidza Voltage (NCV) | Ehe |
| Basa reVFC | Ehe |
| Kutaurirana kweBluetooth | Available on CM2100B model |
| Mabhatiri | 1 Lithium Metal bhatiri (inosanganisirwa) |
| Item Weight | 0.5 Makirogiramu (1.1 makirogiramu) |
| Dimensions (L x W x H) | 9.84 x 5.91 x 7.09 inches (25 x 15 x 18 cm approx.) |
| Certifications | CE, RoHS |
Warranty uye Support
OWON products are designed for reliability and performance. For warranty information or technical support, please refer to the official OWON websaiti kana kubata muparidzi wenzvimbo yako. Chengetedza risiti yako yekutenga sehumbowo hwekutenga kwezvichemo zvewaranti.