1. Nhanganyaya
This manual provides essential information for the safe and effective operation of the KAIWEETS HT206D Smart Digital Clamp Meter. Please read this manual thoroughly before use and retain it for future reference.
2. Safety Information
Always adhere to local and national safety codes. Use appropriate personal protective equipment (PPE) when working with electrical circuits. This device is designed for professional use and requires a basic understanding of electrical principles.
- Usapfuure huwandu hwemapoinzi hunotsanangurwa pachiyero chega chega.
- Chenjerera zvakanyanya paunenge uchishanda nemagetsi aripo.
- Inspect test leads for damage before each use. Replace damaged leads immediately.
- Do not operate the meter if it appears damaged or is not functioning correctly.
- Ita shuwa kuti chivharo chebhatiri chakavharwa zvakachengeteka usati washanda.
- Avoid using the meter in environments with high humidity, extreme temperatures, or explosive gases.
3. Chigadzirwa Pamusoroview
The KAIWEETS HT206D is a smart digital clamp meter designed for accurate electrical measurements. It features a D-shaped jaw for easy clamping and a clear display for readings.

Image 3.1: KAIWEETS HT206D Smart Digital Clamp Meter highlighting key features like 6000 Counts T-RMS, Auto Shutdown, CAT.IV 600V safety rating, and Auto-ranging capability.
Zvinhu zvakakosha zvinosanganisira:
- Smart Mode: Automatically identifies AC/DC voltage/current, resistance, and continuity.
- Chokwadi RMS: Provides accurate measurements for non-linear loads.
- 6000 Counts Ratidza: High-resolution digital display.
- D-Shaped Jaws: Designed for secure clamping and holding test leads.
- Isiri-Yekubatanidza Voltage (NCV) Kuonekwa: Detects electrical status without direct contact.
- Low Pass Sefa (LPF): For accurate measurements on variable frequency drives.
- Mamwe Mabasa: MAX/MIN, Data Hold, Flashlight, Auto-Off.

Mufananidzo 3.2: Pamusoroview of the KAIWEETS HT206D's multi-functional capabilities, showing icons for AC/DC voltage, resistance, continuity, frequency, temperature, NCV, and inrush current measurements.
4. Setup
4.1. Kuiswa kwebhatiri
The meter requires batteries for operation. To install or replace batteries:
- Iva nechokwadi chekuti mita yadzimwa.
- Tsvaga nzvimbo yebhatiri kuseri kwemamita.
- Shandisa screwdriver kuvhura chivharo chebhatiri.
- Isa mabhatiri matsva, uchicherechedza polarity chaiyo.
- Chengetedza chivharo chebheteri.
4.2. Chekutanga Power On
Press the power button to turn on the meter. The default intelligent mode will activate, automatically identifying common measurement signals.
5. Operating Instructions
5.1. Smart Mode
When the meter is powered on, it defaults to Smart Mode. In this mode, the meter automatically detects and measures AC/DC voltage, AC/DC current, resistance, and continuity, simplifying operation.
5.2. Basa Kusarudzwa
Rotate the rotary dial to select specific measurement functions as needed. Press the SEL/FUNC button to cycle through sub-functions within a selected range (e.g., AC/DC voltaguye).
5.3. AC/DC Voltage Kuyera
Kuyera voltage:
- Insert the red test lead into the "VΩHz" input jack and the black test lead into the "COM" input jack.
- Sarudza voltage measurement function using the rotary dial.
- Batanidza bvunzo dzinotungamira mukuenderana nedunhu kana chikamu chiri pasi pekuyedzwa.
- Verenga bhukutage kukosha pachiratidziro.

Image 5.1: Demonstrations of AC/DC Voltage Test (top) and AC/DC Current Test (bottom) using the KAIWEETS HT206D clamp mita.
5.4. AC / DC Current Measurement
Kuyera ikozvino:
- Select the current measurement function (A~) or (A=) using the rotary dial.
- Vhura clamp jaws and enclose only one conductor of the circuit. Ensure the jaws are fully closed.
- Verenga kukosha kwazvino kuri pachiratidziro.
5.5. Resistance and Continuity Measurement
Kuyera kuramba kana kutarisa kuenderera mberi:
- Insert the red test lead into the "VΩHz" input jack and the black test lead into the "COM" input jack.
- Select the resistance/continuity function using the rotary dial.
- Connect the test leads across the component. For continuity, a beep indicates a continuous circuit.
5.6. Vasina-Kubata Voltage (NCV) Kuonekwa
The NCV function allows detection of AC voltage pasina kuonana kwakananga.
- Press the NCV button on the right side of the meter.
- Move the meter's NCV sensor close to the conductor.
- Iyo mita icharatidza kuvepo kwe AC voltage through audible beeps and visual indicators (Low Voltage 'L' or High Voltage 'H').

Image 5.2: Non-contact Voltage Test demonstrating the meter's ability to detect both low and high voltage pasina kubata pamuviri.

Image 5.3: Illustration of activating the NCV function with a long press and the Data Hold function with a short press of the NCV/HOLD button.
5.7. Low Pass Filter (LPF)
The LPF function is used for accurate voltage measurements on variable frequency drives (VFDs) or other noisy circuits. It filters out high-frequency interference.
- Sarudza iyo AC voltage function.
- Press the LPF button to activate the Low Pass Filter.
- Proceed with AC voltage measurement as usual.

Image 5.4: Explanation of the Low Pass Filter (LPF) function, illustrating its effect on measurement accuracy for motor drive outputs.
5.8. Inrush Current Measurement
The Inrush function measures the initial surge current when a device is powered on.
- Select the Inrush current function using the rotary dial.
- Vhura clamp jaws and enclose one conductor of the device to be tested.
- Power on the device. The meter will capture and display the peak inrush current.

Image 5.5: Inrush Current Test in progress, demonstrating the meter's capability to measure the initial current surge with a range of 5-600A.
5.9. Data Hold (HOLD)
Press the BATA button (short press the NCV button) to freeze the current reading on the display. Press it again to release the hold function.
5.10. MAX/MIN Measurement
Press the MAX/MIN button to record the maximum and minimum values during a measurement session. Press again to cycle between MAX, MIN, and current readings.
5.11. Tochi
Press the flashlight button to illuminate the measurement area. Press again to turn it off.
5.12. Auto-Off Basa
The meter will automatically power off after approximately 15 minutes of inactivity to conserve battery life. Press any button or rotate the dial to reactivate it.
6. Kuchengeta
6.1. Kuchenesa
Pukuta mita yacho casing pamwe adamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is dry before storage or use.
6.2. Kutsiviwa kwebhatiri
Tsiva mabhatiri kana chiratidzo chebhatiri diki chaonekwa pachiratidziro. Tarisa Chikamu 4.1 kuti uwane mirairo yekuisa bhatiri.
6.3. Kuchengeta
Kana mita yacho ikasashandiswa kwenguva yakareba, bvisa mabhatiri kuti isadonhe. Chengeta mita yacho munzvimbo inotonhorera, yakaoma, kure nezuva rakananga uye tembiricha yakanyanya.
7. Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Chiyero chemita hachibatidzi. | Mabhatiri akafa kana kuti akaiswa zvisirizvo. | Tsiva mabhatiri, kuve nechokwadi chechokwadi polarity. |
| Kurava kusina kururama. | Incorrect function selected, damaged test leads, or external interference. | Verify function selection, inspect/replace test leads, move away from strong electromagnetic fields. |
| Hapana kurira kwekuenderera mberi. | Open circuit or high resistance. | Check the circuit for breaks or high resistance points. |
| NCV isiri kuona voltage. | Hapana AC voltage present, or sensor not close enough to the conductor. | Iva nechokwadi chekuti AC voltage is present. Move the NCV sensor closer to the live conductor. |
8. Zvinotsanangurwa
The KAIWEETS HT206D Smart Digital Clamp Meter offers the following general specifications:

Image 8.1: Key specifications of the KAIWEETS HT206D, including measurement ranges for current, voltage, capacitance, and display count, along with special features.
- Ratidza: 6000 Counts
- AC/DC Yazvino: Kusvika ku600A
- AC / DC Voltage: Kusvika ku600V
- Capacitance: Up to 100mF
- Tembiricha: Celsius/Fahrenheit
- Chiyero chemhando: Chokwadi RMS
- Safety Rating: CAT.IV 600V
- Kunobva Simba: Battery Powered
- Special Features: Smart Mode, NCV, LPF, LowZ, Inrush Current, Data Hold, MAX/MIN, Flashlight, Auto-Off
9. Warranty uye Tsigiro
KAIWEETS offers a 3-year after-sales service for the HT206D Smart Digital Clamp Meter, along with lifetime technical assistance.
For any questions, technical support, or warranty claims, please contact KAIWEETS customer service through their official channels or the retailer where the product was purchased.