GEYA GEYA-XXX

Bhuku reMirayiridzo yeGEYA Mini ATS Dual Power Automatic Transfer Switch

Model: GEYA-XXX (2P 25A AC220V)

1. Nhanganyaya

The GEYA Mini ATS (Automatic Transfer Switch) is designed to ensure a continuous power supply by automatically switching between a normal power source and a spare (backup) power source. This device is primarily used to detect the status of both power sources. If the normal power supply becomes abnormal, the switch will automatically transfer to the spare power, minimizing interruptions. When the normal power supply is restored, the switch will revert to it. This unit is suitable for household orbit-type installations and is commonly used in PZ30 power distribution boxes for dual power grids operating at 50/60Hz.

The GEYA Mini ATS is characterized by its compact structure, reliable transfer mechanism, ease of installation and maintenance, and long operational lifespan.

2. Safety Information

YAMBIRO: Njodzi yekurohwa nemagetsi. Kuisa nekugadzirisa kunofanira kuitwa chete nevashandi vane hunyanzvi.

  • Always disconnect power from both normal and backup sources before installation, inspection, or maintenance.
  • Ita shuwa kuti zvese zvekubatanidza wiring zvakachengeteka uye zvinoenderana nemakodhi emagetsi emunharaunda.
  • Simbisa vhoriyamutage uye ratings dziripo dze switch dzinoenderana nezvinodiwa ne application yako.
  • Usashandise switch kana ichiita seyakakuvadzwa.
  • The input power supply sequence must be connected correctly to ensure proper operation.

3. Chigadzirwa Pamusoroview

The GEYA Mini ATS is a compact device designed for seamless power transfer. It features indicators for power source status and an auto/manual selection switch.

Mberi view of the GEYA Mini ATS Dual Power Automatic Transfer Switch

Mufananidzo 3.1: Mberi view of the GEYA Mini ATS. This image shows the main components including the input terminals (I and II), output terminals (LOAD), status indicators, and the auto/manual switch.

Diagram illustrating uninterruptible power supply concept with GEYA ATS

Figure 3.2: Conceptual diagram of the GEYA ATS in an uninterruptible power supply setup. It shows how the switch connects between a normal power source (e.g., grid city power) and a backup power source (e.g., AC generator, inverter) to supply power to the load.

4. Setup uye Kuiswa

This device is designed for DIN rail mounting within a PZ30 power distribution box. Follow these steps for proper installation:

  1. Kukwidza: Securely attach the ATS to a standard DIN rail.
  2. Wiring: Connect the normal power source to terminals labeled (I) and the backup power source to terminals labeled (II). Connect the load to the terminals labeled LOAD. Ensure the neutral wire is connected to the 'N' terminal and the live wire to the 'A' terminal for each input and output.
  3. Voltage Sarudzo: Iva nechokwadi chekuti voltage model is used for your system. For 2P 25A 220V models, this is suitable for 220V/400V systems or single-line 220V applications.
  4. Terminal Connections: The terminal wiring area accommodates 1 to 25mm² wires. Use an M5 screw for connections and tighten to a torque of 2.5 N.m.
Detailed wiring instructions for GEYA Mini ATS

Figure 4.1: Detailed wiring diagram showing connections for backup power, common power supply, load power, and the various terminals and controls on the GEYA Mini ATS.

Voltage selection guide for GEYA ATS models

Figure 4.2: Guide for choosing the correct voltage model. It specifies that 2P 220V models are for 220V/400V systems or single-line 220V, and 2P 110V models are for 110V/220V systems or single-line 110V. Incorrect voltage can damage the control circuit.

Dimensions and mounting details for GEYA Mini ATS

Figure 4.3: Technical drawing showing the dimensions of the GEYA Mini ATS, including width, height, and depth, along with DIN rail mounting specifications. Terminal wiring area and screw torque are also indicated.

5. Operating Instructions

The GEYA Mini ATS offers both automatic and manual operation modes.

  • Automatic Mode: Set the switch to 'Auto'. In this mode, the device continuously monitors both power sources. If the primary (normal) power fails or drops below acceptable levels, the switch will automatically transfer the load to the secondary (backup) power source. When the primary power is restored, the switch will automatically revert the load back to the primary source.
  • Manual Mode: Set the switch to 'Manual'. In this mode, you can manually select between power source I and power source II using the operation handle. This mode is useful for testing or specific maintenance scenarios.

Chiziviso Chakakosha: While the transfer time is fast (typically less than 50ms), it may not be instantaneous enough for highly sensitive electronic equipment like computers to remain powered without a momentary interruption. For such applications, an additional Uninterruptible Power Supply (UPS) may be required for the sensitive load.

6. Kuchengeta

Regular maintenance ensures the longevity and reliable operation of your GEYA Mini ATS.

  • Visual Inspection: Periodically inspect the switch for any signs of physical damage, loose connections, or overheating.
  • Terminal Tightness: Check and re-tighten all terminal screws as necessary to prevent arcing and ensure good electrical contact.
  • Kuchenesa: Keep the switch free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • Kushanda Muedzo: Regularly test the automatic transfer function by simulating a power outage on the primary source (if safe to do so and with appropriate precautions).

7. Kugadzirisa matambudziko

If you encounter issues with your GEYA Mini ATS, consider the following:

  • No Transfer:
    • Check if both power sources (Normal and Backup) are active and within acceptable voltage ranges.
    • Ensure the switch is set to 'Auto' mode.
    • Iva nechokwadi chekuti mawaya ese akabatana akachengeteka uye akarurama zvichienderana nedhayagiramu.
    • Confirm the control voltage is within the rated operating voltage (85%-110% of 220V AC).
  • Partial Power/Intermittent Operation:
    • Inspect for loose terminal connections.
    • Check for signs of overheating or damaged wiring.
  • Switch Does Not Stay in Position:
    • If in manual mode, ensure the handle is fully engaged.
    • If in auto mode, this could indicate an issue with the internal mechanism or control circuit.

If problems persist after basic troubleshooting, contact qualified electrical personnel or GEYA customer support.

8. Zvinotsanangurwa

Table of main technical parameters for GEYA Mini ATS

Figure 8.1: Main technical parameters of the GEYA Mini ATS, detailing electrical ratings and performance characteristics.

GEYA Mini ATS (Model GEYA-XXX) Technical Specifications
ParameterValue
Case Grade63
Rated Operating Current Ie(A)6A/10A/16A/20A/25A/32A/40A/50A/63A (This model: 25A)
Rated Insulation Voltage Ui690V
Rated Impulse Withstand Voltage Uimp8kV
Rated Working Voltage UeAC220V/AC110V (This model: AC220V)
Rated Frequency50/60Hz
KirasiPC class
Pole Number2P
Rated Short-Circuit Current Iq50kA
Chishandiso Chekudzivirira Dunhu Repfupi (Fuse)RT16-00-63A
Rated Control Voltage UsAC220V, 50Hz
Normal Working Conditions85%-110% Us
Webetsero CircuitAC220V/110V 50Hz Ie=5A
Nguva Yekuchinja KweContactor<50ms
Nguva Yokuchinja Kwekushanda<50ms
Nguva Yekuchinjana Kwekudzoka<50ms
Power Off Nguva<50ms
Mechanical Life≥8000 nguva
Upenyu hweMagetsi≥1500 nguva
Chikamu ChekushandisaAC-31B
Package Dimensions4.92 x 3.35 x 2.24 inches
Item Weight13.12 ounces
MaterialMhangura
Operation ModeAUTO
Contact TypeKazhinji Open
Connector TypeClamp
TerminalChikururu
Circuit Type2-nzira
Actuator TypeRotary

9. Warranty uye Tsigiro

For warranty information, technical support, or service inquiries, please contact GEYA customer support or refer to the official GEYA website. Chengeta risiti yako yekutenga yezvichemo zvewaranti.

You can visit the official GEYA store for more information: GEYA Store on Amazon

Related Documents - GEYA-XXX

Preview Zhejiang Geya Electrical Uninterruptible Millisecond Switching Dual Automatic Transfer Switch Manual
Bhuku rino rinopa ruzivo rwakadzama nezve Zhejiang Geya Electrical Co., Ltd. Uninterruptible Millisecond Switching Dual Automatic Transfer Switch, kusanganisira ruzivo rwakawanda, hunyanzvi hwekugadzirisa, kuisa, waya, kugadzirisa, uye matanho ekuchengetedza.
Preview GEYA Automatic Transfer Switch (ATS) G2R-63/00 - Madiro Ehunyanzvi
Yakadzama tekinoroji yakatarwa uye yekumisikidza gwai reiyo GEYA G2R-63/00 Otomatiki Shandura Shandura (ATS), ine PC kirasi inochinja kune mbiri magetsi masosi, mamiriro ekushanda, uye maitiro ekugadzirisa.
Preview Katarogu yezvigadzirwa zvekudzivirira simba remagetsi yeGEYA
Katarogu yakazara yeGEYA's over/under voltage uye magadzirirwo emagetsi, maswichi ekufambisa otomatiki, uye zvishandiso zvekuyera simba, zvine hunyanzvi, maficha, uye gwara rekuisa mamodheru akasiyana-siyana.
Preview GEYA GRIS8 Isolated Relay Instruction Manual - Technical Specifications and Operation
Instruction manual for the GEYA GRIS8 series isolated relays, covering applications, features, technical specifications, panel and connection diagrams, and dimensions. Suitable for fire safety, HVAC, elevator, and access control systems.
Preview Bhuku reMirayiridzo yeGEYA GRW8 Temperature Control Relay
Instruction manual for the GEYA GRW8 series temperature control and temperature range control relays. Features include universal supply, LED status indication, and DIN rail mounting. Covers applications, function features, technical parameters, panel diagrams, wiring diagrams, and dimensions.
Preview GEYA GPS8-05 Voltage / Bhuku reMirayiridzo yeMudziviriri weParizvino
Bhuku remirayiridzo reGEYA GPS8-05 Voltage / Current Protector, detailing its applications, features, technical specifications, parameter settings, wiring, and operational diagrams for household equipment protection.