UNI-T UT334E

UNI-T UT334E Gas Leak Detector

Bhuku reMirayiridzo

1. Nhanganyaya

The UNI-T UT334E is a portable, voice-enabled, four-in-one gas detector designed for continuous monitoring of gas concentrations. This safety device utilizes advanced integrated circuit technology, embedded microcomputer control, and high-quality imported gas sensors to provide excellent sensitivity and repeatability. It features a dot matrix LCD display with support for both English and Chinese interfaces and voice prompts, ensuring ease of use and maintenance. The robust shell is constructed from high-strength engineering plastic, offering good vibration resistance, high strength, and protection against dust, water, and explosions.

UNI-T UT334E Gas Leak Detector front view
Mufananidzo 1: Mberi view of the UNI-T UT334E Gas Leak Detector.
UNI-T UT334E indicating detection of EX, H2S, CO, O2 gases
Figure 2: The UT334E is capable of detecting four types of gases: EX (combustible gas), H2S (hydrogen sulfide), CO (carbon monoxide), and O2 (oxygen).

2. Zvigadzirwa zveChigadzirwa

The UT334E gas detector incorporates several key features to ensure reliable and user-friendly operation:

  • Tsigiro yemitauro yakawanda: Switch between English and Chinese interfaces and voice prompts.
  • Quadruple Alarm System: Provides sound, light, vibration, and screen flashing alarms for comprehensive alert notification.
  • Bhatiri rinogara kwenguva refu: Equipped with a 2500mAh built-in high-capacity lithium battery for extended operation.
  • Kuchengeta Data: Automatically stores detection records, which can be easily viewed uye yakadzimwa.
  • Zvakajeka Kuratidzwa: Features a 2.4-inch color LCD display for clear visualization of gas concentrations and device status.
  • Durable Construction: Made from high-strength engineering plastic, offering resistance to compression, drops, and explosion-proof properties.
  • High-Precision Sensors: Utilizes imported sensors for sensitive induction, short response time, and accurate detection.
  • Curve Drawing Function: Supports graphical representation of gas concentration over time, aiding in observing periodic states.
UNI-T UT334E features list and device illustration
Mufananidzo 3: Kupfuuraview of the key features of the UT334E series gas detector.

3. Setup

Before using your UNI-T UT334E gas detector, please follow these setup instructions:

  1. Kuburitsa: Carefully remove the device and all accessories from the packaging. Inspect for any signs of damage.
  2. Chekutanga Charge: Connect the device to a power source using the provided MicroUSB cable. Ensure the battery is fully charged before first use. A full charge typically takes approximately 4 hours.
  3. Power On: Press and hold the power button until the LCD screen illuminates. The device will perform a self-test.
  4. Sarudzo yeMutauro: If prompted, select your preferred language (English or Chinese) using the navigation buttons.
UNI-T UT334E charging via MicroUSB
Figure 4: The UT334E charging via a MicroUSB cable, compatible with standard Android phone chargers and power banks.

4. Operating Instructions

The UT334E is designed for straightforward operation. Here are the basic steps for gas detection:

  1. Power On: Press and hold the power button to turn on the device. Allow it to complete its startup sequence and sensor calibration.
  2. Monitoring: Once powered on, the device will continuously monitor the ambient air for the four specified gases (EX, H2S, CO, O2). Real-time concentrations will be displayed on the 2.4-inch color LCD screen.
  3. Alarm Thresholds: The device has pre-set low and high alarm points for each gas. These can often be adjusted through the device's menu settings if required.
  4. Curve Drawing: To observe gas concentration trends, navigate to the curve drawing function via the menu. This feature displays a graphical representation of gas levels over time.
  5. Data Review: Access the stored records through the menu to review past detection data. Records can also be deleted from this section.
  6. Power Off: Dzvanya uye bata bhatani remagetsi kusvika mudziyo wadzima.
UNI-T UT334E displaying gas concentration curve
Figure 5: The curve drawing feature allows users to easily observe gas concentration and its cycle status over time.

5. Alarms and Indicators

The UT334E employs a comprehensive quadruple alarm system to alert users to hazardous gas levels:

  • Inonzwika Alarm: A loud buzzer will sound when gas concentrations exceed set thresholds.
  • Alarm yekuona: Indicator lights will flash, and the screen may change color (e.g., red background) to visually signal an alarm condition.
  • Alarm yeVibration: The device will vibrate, providing a tactile alert, especially useful in noisy environments.
  • Screen Flashing: The LCD screen will flash to draw immediate attention to the detected hazard.

These alarms activate when gas levels reach either the low or high alarm points configured for each gas type.

UNI-T UT334E showing quadruple alarm indicators
Figure 6: Illustration of the quadruple alarm prompt system, including lights flicker, buzzer alarm, red background reminder, and body vibration.

6. Kuchengeta

Proper maintenance ensures the longevity and accuracy of your gas detector:

  • Kuchenesa: Regularly wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor Care: Avoid exposing the sensors to extreme temperatures, high humidity, or corrosive substances, as this can affect their lifespan and accuracy. The typical sensor life is 2 years.
  • Battery Management: Recharge the battery when the low battery indicator appears. Avoid fully discharging the battery frequently to prolong its life.
  • Kuchengeta: Kana usingashandiswe kwenguva yakareba, chengeta mudziyo wacho munzvimbo inotonhorera, yakaoma pasina chiedza chezuva uye tembiricha yakanyanyisa.
  • Calibration: For professional applications, periodic calibration of the sensors may be required to maintain accuracy. Refer to local regulations and industry standards.

7. Kugadzirisa matambudziko

If you encounter issues with your UT334E gas detector, consider the following:

  • Mudziyo Haubatiki. Iva nechokwadi chekuti bhatiri rachajwa. Batanidza mudziyo pachaja woedza zvakare.
  • Kuverenga Kusina Kurongeka: Ensure the sensors are clean and unobstructed. If readings remain inconsistent, the sensors may require calibration or replacement.
  • Alarms Not Functioning: Check the device settings to ensure alarms are enabled. Verify that the volume and vibration settings are appropriate for your environment.
  • Screen Matambudziko: If the screen is blank or flickering, try restarting the device. If the problem persists, contact customer support.

For persistent issues or technical support, please refer to the contact information provided in the warranty and support section.

8. Zvinotsanangurwa

Detailed technical specifications for the UNI-T UT334E Gas Leak Detector:

Table of UNI-T UT334E specifications including gas detection ranges, alarm points, resolution, response time, display error, working environment, operating voltage, charging time, standby time, sensor life, physical dimensions, and weight.
Figure 7: Detailed specifications for the UT334E Gas Leak Detector.
General Specifications
ParameterValue
MugadziriUNI-Trend
Model NumberHY-UT334E
Item Weight1.32 makirogiramu (0.6 kg)
Product Dimensions6.5 x 4.33 x 4.72 inches (165 x 110 x 120 mm)
MaterialAcrylonitrile Butadiene Styrene (ABS)
Simba SourceBattery Powered
Wattage5 watts
Chiyero Chakarurama±0.1%
CertificationsCE, ISO 9001, RoHS, UKCA
Bhatiri TypeLithium Metal (yakabatanidzwa)
Battery Capacity2500mAh
Kuchaja Nguva4 maawa
Standby TimeKupfuura maawa gumi
Sensor Hupenyu2 years
Nzvimbo YekushandaTemperature: -20°C to 50°C; Humidity: <95%RH (non-condensing)

9. Warranty uye Tsigiro

UNI-T products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please contact your authorized UNI-T dealer or visit the official UNI-T website. Chengetedza risiti yako yekutenga sehumbowo hwekutenga kwezvichemo zvewaranti.

Related Documents - UT334E

Preview UNI-T UT336B Refrigerant Leak Detector User Manual uye Matsanangudzo
Yakazara mushandisi manyorerwo uye tekinoroji maratidziro eUNI-T UT336B Refrigerant Leak Detector, inodonongodza maitiro ayo, mashandiro, chengetedzo, kugadzirisa matambudziko, uye kugadzirisa.
Preview UNI-T UT662 Series Multi-functional Intelligent Leak Detector User Manual
Chinyorwa chemushandisi cheUNI-T UT662 Series Multi-functional Intelligent Leak Detector, ichipa ruzivo rwakadzama pakuseta, mashandiro, maficha, kugadzirisa, kugadzirisa matambudziko, uye zvirevo zvekuonekwa kwemvura inodonha.
Preview UNI-T UT262E Phase Sequence Detector User Manual
Yakakwana mushandisi bhuku reUNI-T UT262E Phase Sequence Detector. Dzidza nezve maficha ayo, maratidziro, kuchengetedza, mirairo yekushandisa, uye kugadzirisa dambudziko kune isiri-yekubata 3-chikamu chekutevedzana kuyedzwa.
Preview UNI-T UT387B Wall Detector User Manual: Zvimiro, Mashandiro, uye Zvinotsanangurwa.
Chinyorwa chemushandisi cheUNI-T UT387B Wall Detector, inodonongodza maitiro ayo, matanho ekushandisa ekuona simbi, waya dzeAC, uye huni, hunyanzvi hwekuita, kugadzirisa, uye kuchengetedza.
Preview Bhuku rekushandisa reUNI-T UT336A Refrigerant Leak Detector
Bhuku rekushandisa reUNI-T UT336A Refrigerant Leak Detector. Rinopa ruzivo rwakadzama nezvemaficha, mashandisirwo, nhungamiro dzekuchengetedza, marongero, kugadzirisa matambudziko, uye kugadzirisa kuona maburi ari mufiriji muHVAC uye masisitimu efiriji.
Preview UNI-T UT334A Radiation Dose Tester Mushandisi Manual
Bhuku rekushandisa rakazara reUNI-T UT334A Radiation Dose Tester, rinotsanangura maficha ayo, marongero ayo, mashandiro ayo, mirairo yekuchengetedza, uye ruzivo rwewarandi.