briidea HRWL-01W

Briidea HRWL-01W Fresh Water Tank Level Indicator User Manual

Model: HRWL-01W | Brand: briidea

1. Nhanganyaya

The Briidea HRWL-01W Fresh Water Tank Level Indicator is designed to provide accurate and hygienic monitoring of fresh water levels in RVs, caravans, and boats. This non-contact sensor system helps users keep track of their water supply, ensuring timely refills and preventing empty tanks. This manual provides comprehensive instructions for the installation, operation, and maintenance of your device.

2. Chigadzirwa Pamusoroview

2.1 Mamiriro Akakosha

  • Kwete-Kuonana Ensures fresh water remains clean and hygienic as the sensor does not touch the water.
  • Real-time Monitoring: Provides immediate water level feedback via an LED display.
  • Wide Application: Suitable for RVs, boats, caravans, and other off-grid applications.
  • Power-Down Memory: Retains settings after initial configuration, eliminating the need for re-setup after power interruptions.
  • Broad Voltage Kuenderana: Operates on DC 7-32V power supply.
  • Kudzama kwekuona: Supports detection depths up to 400 cm.

2.2 Zvikamu

The Briidea HRWL-01W system includes the main LED indicator panel and a non-contact water level sensor.

Briidea HRWL-01W Fresh Water Tank Level Indicator and Sensor
Mufananidzo 1: Briidea HRWL-01W Indicator Panel and Non-Contact Sensor. The image shows a white rectangular LED indicator panel on the left, displaying water levels from 10% to 100% with corresponding colored lights. On the right, a black cylindrical non-contact sensor with an attached cable is shown.

3. Important Considerations for Installation

For optimal performance and accurate readings, please observe the following critical points:

  • Sensor kuiswa: The sensor should be installed in the centre yetangi remvura.
  • Tangi Dimensions: The water tank's length-to-height ratio should ideally be 1:0.5 (meaning the length is twice the height). Please verify your tank dimensions for compatibility before installation.
  • Calibration Condition: Ensure the sensor is dry during the calibration process. Direct contact with water during calibration can affect sensor values and accuracy.
  • Metal Tanks: Be aware that some metal water tanks may compromise the accuracy of the measurement.
Diagram illustrating non-contact detection method and tank ratio requirement
Mufananidzo 2: Non-Contact Detection Method and Tank Ratio. This diagram illustrates the sensor's placement in the middle of the tank and highlights the recommended tank length-to-height ratio of 1:0.5 for accurate detection.

4. Setup uye Kuiswa

4.1 Wiring Mirayiridzo

Connect the indicator panel to your DC power source (7-32V) and the sensor as shown in the diagram below. Ensure all connections are secure and correctly polarized.

Wiring diagram for Briidea HRWL-01W
Mufananidzo 3: Simple Wiring Diagram. The diagram shows the indicator panel connected to a battery (power source) and the water tank sensor. Red wires typically indicate positive connections, and black wires indicate negative/ground connections.

4.2 Sensor and Panel Mounting

  1. Mount the indicator panel in a visible location within your RV or caravan. The panel is designed for wall mounting.
  2. Install the non-contact sensor on the exterior of your fresh water tank, ensuring it is positioned in the center of the tank for optimal accuracy.
  3. Ensure the sensor is dry during initial setup and calibration.
Briidea HRWL-01W LED display mounted on an RV interior wall
Mufananidzo 4: LED Display in Context. This image shows the Briidea HRWL-01W indicator panel mounted on an interior wall of an RV, next to other control switches, demonstrating its discreet integration.

5. Operating Instructions

5.1 Kubatidza

Once correctly wired and powered, the indicator panel will illuminate, displaying the current fresh water level.

5.2 Kuverenga Chiratidziro

The LED display shows water levels in increments from 10% to 100%. Different colored lights may indicate various levels (e.g., green for high, yellow for medium, red for low). Refer to the panel's markings for specific percentage indications.

5.3 Power-Down Memory Function

The device features a Power-Down Memory function. After the initial setup and calibration, the settings are saved. In the event of a power interruption or when the device is turned off and on again, it will retain its previous configuration, eliminating the need for re-calibration.

Briidea HRWL-01W indicator installed in an RV kitchen area
Mufananidzo 5: Indicator in RV Interior. This image shows the Briidea HRWL-01W indicator panel seamlessly integrated into the kitchen area of an RV, providing a clear view yezinga remvura.

6. Kuchengeta

  • Sensor Utsanana: While the sensor is non-contact, ensure its exterior surface remains clean and free from debris that could obstruct its operation.
  • Calibration: If you suspect inaccurate readings, re-calibrate the sensor. Always ensure the sensor is dry during calibration.
  • Magetsi: Ensure a stable DC 7-32V power supply to prevent erratic behavior.

7. Kugadzirisa matambudziko

  • Kuverenga Kusina Kurongeka:
    • Verify sensor placement: Is it in the center of the tank?
    • Check tank dimensions: Does your tank meet the 1:0.5 length-to-height ratio?
    • Ensure sensor is dry during calibration.
    • Consider if your tank is metal, which can affect accuracy.
  • Hapana Chiratidziro/Simba:
    • Tarisa zvese zvinobatanidzwa netambo kuti zvionekwe kuti hazvina kusimba here kana kuti hazvina kunyatsoshanda zvakanaka.
    • Verify the DC power supply is within the 7-32V range and functioning correctly.
  • Sensor Malfunction (e.g., if sensor gets wet): The sensor is designed for non-contact use. If it comes into direct contact with water, it may malfunction or provide incorrect readings. Ensure the sensor remains dry and is installed externally to the tank.

8. Zvinotsanangurwa

ModelHRWL-01W (br-042)
Brandbriidea
Kudzora NziraBata
Mounting TypeGomo reMasvingo
Sensor TechnologyUltrasonic Sensor
Simba SourceCorded Electric
Chiyamuro VoltageDC 7-32 Volts
Inowirirana DevicesRV, Boat, Caravan
Item Weight160 g
Package Dimensions11.2 x 9.4 x 3.4 cm
Dimensions of Briidea HRWL-01W indicator and sensor
Mufananidzo 6: Product Dimensions. This image provides the physical dimensions of the indicator panel (8.5 cm height, 4.7 cm width) and the sensor (2.9 cm diameter, 2.4 cm height) with a 1.5 m cable.

9. Kushandisa Examples

The Briidea HRWL-01W is versatile and can be used in various mobile and off-grid settings to monitor fresh water levels.

Various application scenarios for the Briidea HRWL-01W
Mufananidzo 7: Wide Application. This collage shows the Briidea HRWL-01W indicator alongside images of various vehicles and setups, including RVs, caravans, and boats, illustrating its broad compatibility for water level monitoring.

10. Warranty uye Tsigiro

For warranty information or technical support, please refer to the product packaging or contact briidea customer service directly. Keep your purchase receipt for warranty claims.

Related Documents - HRWL-01W

Preview Briidea HASS-05 AC Soft Starter User Manual
Chinyorwa chemushandisi cheBriidea HASS-05 AC Soft Starter, inodonongodza maitiro ayo, mabhenefiti, zvakatemwa, uye gidhi yekuisa. Iyi yakapfava yekutanga yakagadzirirwa kudzikisa inrush ikozvino kune AC mota, ichipa reverse mota dziviriro uye nyore kuisirwa.
Preview briidea HASS-05 AC Yakapfava Starter Mushandisi Manual uye Kuisa Gwaro
Yakakwana mushandisi bhuku uye yekumisikidza gwara rebriidea HASS-05 AC Yakapfava Starter. Dzidza nezve maficha ayo, mabhenefiti, tekinoroji yakatarwa, kuchengetedza, uye nhanho-ne-nhanho wiring uye yekuisa maitiro eHVAC masisitimu.
Preview MIKO MAH-01W Humidifier User Manual: Operation, Cleaning, and Troubleshooting
Comprehensive user manual for the MIKO MAH-01W humidifier. Learn about operation, safety instructions, cleaning, descaling, troubleshooting, technical specifications, and disposal.
Preview RD866 Handheld Walkie Talkie Operating Instructions
Operating instructions for the RD866 0.01W/0.5W Handheld Walkie Talkie, including safety information, installation, operation, troubleshooting, and FCC compliance.