PCE Instruments PCE-HVAC 10

PCE Instruments PCE-HVAC 10 Digital Pressure Gauge User Manual

This manual provides instructions for the safe and efficient operation of the PCE-HVAC 10 Digital Pressure Gauge, designed for HVAC/Refrigeration service.

1. Nhanganyaya

The PCE-HVAC 10 Digital Pressure Gauge is a robust measuring instrument engineered for daily use in refrigeration systems and heat pumps. It accurately determines pressure and temperature, supporting commissioning, servicing, and maintenance tasks. The device features a durable metal casing, a 2-way valve block, and comes with two NTC clamp-on temperature sensors and refrigerant hoses for comprehensive measurement capabilities. With 83 preloaded refrigerants and functions like automatic heat pump mode and temperature-compensated density testing, it simplifies complex operations.

2. Safety Information

Please read this manual thoroughly before operating the PCE-HVAC 10 Digital Pressure Gauge. Failure to follow safety instructions may result in injury or damage to the device. Keep this manual for future reference.

3. Package Zviri mukati

Tarisa kuti zvinhu zvese zvakanyorwa pazasi zviripo mupakeji yako:

PCE-HVAC 10 Digital Pressure Gauge kit in carrying case

Image of the PCE-HVAC 10 Digital Pressure Gauge kit, including the main unit, refrigerant hoses, and NTC clamp sensors, neatly arranged in a protective carrying case.

4. Chigadzirwa Pamusoroview

The PCE-HVAC 10 is designed for precision and ease of use in demanding HVAC/R environments. Its robust metal casing ensures durability, while the intuitive interface provides clear readings.

Zvinokosha:

Mberi view of PCE-HVAC 10 Digital Pressure Gauge

Mberi view of the PCE-HVAC 10 Digital Pressure Gauge, showcasing its robust casing and clear LCD display.

PCE-HVAC 10 display with hanging fixture

Close-up of the PCE-HVAC 10 display, showing measurement readings and the integrated hanging hook for convenient placement.

5. Setup

5.1 Kuiswa kwebhatiri

  1. Tsvaga nzvimbo yebhatiri iri kumashure kwemudziyo.
  2. Vhura chivharo chekamuri.
  3. Isa 4 x 1.5V AA mabhatiri, chengetedza polarity chaiyo.
  4. Vhara chivharo chebhatiri zvakachengeteka.

5.2 Connecting Sensors and Hoses

The PCE-HVAC 10 utilizes a 2-way valve block with three connectors for refrigerant hoses and dedicated ports for NTC clamp sensors.

PCE-HVAC 10 connection ports

Detailed view of the PCE-HVAC 10's connection ports for NTC clamp sensors and refrigerant hoses.

PCE-HVAC 10 2-way valve block

Side view of the PCE-HVAC 10 showing the metal 2-way valve block with three connectors for refrigerant hoses.

Refrigerant hoses for PCE-HVAC 10

The three color-coded refrigerant hoses (red, blue, yellow) included with the PCE-HVAC 10, used for connecting to HVAC systems.

6. Operating Instructions

6.1 Simba On/Kudzima

Dzvanya uye ubate bhatani remagetsi (rinowanzo nyorwa ne /) kuti ubatidze kana kudzima mudziyo.

6.2 Menyu Navigation

Shandisa iyo MODE button to cycle through different measurement modes or display screens. The SET button is used to confirm selections or enter settings menus. Use the arrow buttons (/) to navigate options or adjust values. The ESC button allows you to exit a menu or cancel an operation.

6.3 Refrigerant Selection

The PCE-HVAC 10 has 83 preloaded refrigerants. To select the appropriate refrigerant for your system:

  1. Enter the refrigerant selection menu (refer to the device's on-screen prompts or specific button combination).
  2. Use the arrow buttons to scroll through the list of refrigerants.
  3. Press SET to confirm your selection. The selected refrigerant will be displayed on the measurement screen.

6.4 Kuyera Kwekuita

Once the sensors and hoses are connected and the refrigerant is selected, the device will display real-time pressure and temperature readings. Ensure proper connection to the HVAC/R system for accurate measurements.

6.5 Using the 2-Way Valve Block

The metal 2-way valve block allows for controlled charging, evacuation, and testing of refrigeration systems. Operate the valves carefully to manage refrigerant flow and pressure.

6.6 Mabasa Akakosha

Technician using PCE-HVAC 10 on HVAC system

A technician using the PCE-HVAC 10 Digital Pressure Gauge to monitor an HVAC system, with hoses connected.

PCE-HVAC 10 display showing measurements

Close-up of the PCE-HVAC 10 display showing real-time pressure and temperature readings for a selected refrigerant.

7. Kuchengeta

7.1 Kuchenesa

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device openings.

7.2 Kutsiviwa kwebhatiri

Replace the batteries when the low battery indicator appears on the display. Follow the battery installation steps outlined in Section 5.1.

7.3 Kuchengeta

When not in use, store the PCE-HVAC 10 in its protective carrying case in a dry environment. The recommended storage temperature range is -20 to 60°C / -4 to 140°F with a relative humidity of 10% to 95%.

8. Kugadzirisa matambudziko

If you encounter issues with your PCE-HVAC 10, consider the following common solutions:

For persistent issues, contact PCE Instruments customer support.

9. Zvinotsanangurwa

ParameterValue
Product Dimensions8.03 x 4.57 x 2.56 inches
Item Weight1.7 makirogiramu (768g)
Pressure Measurement Range-1 kusvika +60 bar
Kururama Kwekumanikidza0.5% FS
Temperature Measurement Range-10 kusvika +200°C / 14 kusvika 392°F
Tembiricha Resolution0.1°C / 0.18°F
Magetsi4 x 1.5V AA mabhatiri
Dziviriro KirasiIP42
Operating Temperature0 kusvika 45°C / 32 kusvika 113°F
Kushanda Humidity10% kusvika 95% RH (isina-condensing)
Storage Temperature-20 kusvika 60 ° C / -4 kusvika 140 ° F
Kuchengetedza Humidity10% kusvika 95% RH (isina-condensing)

10. Warranty uye Tsigiro

PCE Instruments products are manufactured under strict quality control. This product is covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the PCE Instruments websaiti kune yakadzama waranti mazwi uye mamiriro.

For technical support, service, or calibration, please contact PCE Instruments directly. Our qualified technicians are available to assist you with any questions or issues you may have regarding the PCE-HVAC 10 Digital Pressure Gauge.

PCE Instruments Contact Information:
Ndapota shanya www.pce-instruments.com kuti uwane ruzivo rwakanangana nedunhu rako.

Related Documents - PCE-HVAC 10

Preview Bhuku rekushandisa rePCE-RRU 10 Refrigerant Recovery Device
Bhuku rekushandisa rePCE-RRU 10 Refrigerant Recovery Device, rinotsanangura mashandisirwo ayo, mashandiro ayo, gwara rekuchengetedza, uye kugadzirisa matambudziko.
Preview PCE-HFG Series Hydraulic Force Gauge User Manual
User manual for the PCE-HFG Series Hydraulic Force Gauge by PCE Instruments, covering specifications, operation, maintenance, safety, and disposal. Includes technical details and contact information.
Preview PCE-VT 3800/3900 Vibration Meter User Manual
Chinyorwa chemushandisi chePCE Instruments' PCE-VT 3800 uye PCE-VT 3900 vibration mita. Inovhara zvakatsanangurwa zvakatemwa, mashandiro, kuyerwa modes, kutema dhata, FFT, RPM, kuyerwa kwenzira, chengetedzo, uye kuenzanisa kweanoshanda mamiriro emuchina.
Preview Bhuku rekushandisa rePCE-RRM 250 Refrigerant Recovery Machine
Bhuku rekushandisa rakakwana rePCE-RRM 250 Refrigerant Recovery Machine nePCE Instruments. Rinovhara kuchengetedzeka, mashandiro, zvinodiwa, zvikamu, nzira dzekudzoreredza, uye matambudziko ekugadzirisa matambudziko evashandi veHVAC.
Preview Bhuku Rekushandisa - PCE-FM 200 / PCE-FM 50N / PCE-FM 500N Force Gauge
User manual for the PCE-FM 200, PCE-FM 50N, and PCE-FM 500N Force Gauges by PCE Instruments. This document provides detailed information on safety precautions, specifications, device description, operation, calibration, and disposal.
Preview PCE-UX 3081/3081WQ Moisture Analyzer: Operating Instruction and Technical Guide.
Yakazara mirairo yekushanda uye tekinoroji kutsanangurwa kwePCE-UX 3081 uye PCE-UX 3081WQ mwando analyzer. Dzidza nezve setup, mashandiro, chengetedzo, kugadzirisa, uye kugadzirisa kune hunyoro hwakakwana uye yakaoma nyaya yekuongorora uchishandisa thermogravimetric nzira.