Qoltec 50900

QOLTEC 50900 Three Phase Electronic Energy Consumption Meter User Manual

1. Nhanganyaya

This manual provides detailed instructions for the installation, operation, and maintenance of the QOLTEC 50900 Three Phase Electronic Energy Consumption Meter. This device is designed for measuring active energy consumption in three-phase, four-wire AC circuits. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Safety Information

YAMBIRO: Installation and maintenance of this device must be performed by qualified personnel only. Failure to follow these instructions can result in electric shock, fire, or serious injury.

3. Chigadzirwa Pamusoroview

The QOLTEC 50900 is a compact, DIN rail mountable electronic energy meter designed for accurate measurement of three-phase energy consumption. It features an LCD display for clear readings and a pulse output for remote monitoring.

QOLTEC 50900 Energy Meter with dimensions and key features

Figure 3.1: QOLTEC 50900 Energy Meter showing dimensions (75mm x 92mm x 76mm) and key features like Three Phase Type, 230V Rated Voltage, 1.0 Precision Class, and LCD Display.

Zvinokosha:

4. Zvinotsanangurwa

ParameterValue
Model50900
Rated Voltage3x230/400V AC
Rated Current3x10(100)A
Frequency50Hz
Kirasi Yakarurama1.0
DisplayLCD
Pulse Output400imp/kWh
InstallationDIN Rail (4P)
Zviyero (W x H x D)75 x 92 x 76 mm
Kurema100 g
MaterialAcrylic

5. Setup uye Kuiswa

The QOLTEC 50900 meter is designed for standard 35mm DIN rail mounting. Ensure the installation location is dry, well-ventilated, and free from excessive vibration or electromagnetic interference.

5.1 Kuiswa

  1. Locate a suitable 35mm DIN rail within your electrical panel.
  2. Align the meter's DIN rail clip with the rail.
  3. Press the meter firmly onto the rail until it clicks into place.
QOLTEC 50900 Energy Meter mounted on a DIN rail

Figure 5.1: The QOLTEC 50900 meter securely mounted on a DIN rail, showing its compact form factor.

5.2 Wiring Connections

ZVINOKOSHA: All wiring must comply with local electrical codes and regulations. Ensure power is OFF before making any connections.

  1. Identify the input (IN) and output (OUT) terminals on the meter.
  2. Connect the incoming three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding IN terminals (typically 5, 6, 7, 8).
  3. Connect the outgoing three-phase lines (L1, L2, L3) and Neutral (N) to the corresponding OUT terminals (typically 1, 2, 3, 4).
  4. Iva nechokwadi chekuti zvese zvakabatana zvakasimba uye zvakachengeteka kudzivirira kusangana kwakasununguka uye kupisa zvakanyanya.
Wiring diagram for QOLTEC 50900 Energy Meter showing input and output terminals

Mufananidzo 5.2: Rutivi view of the meter showing the wiring diagram for input (IN) and output (OUT) connections for L1, L2, L3, and Neutral.

Front and terminal views of QOLTEC 50900 Energy Meter

Mufananidzo 5.3: Mberi view of the meter with its LCD display and a separate view of the terminal block for wiring connections.

6. Operating Instructions

Once properly installed and powered, the QOLTEC 50900 meter will automatically begin measuring energy consumption.

6.1 LCD Ratidza

The LCD displays the total active energy consumption in kilowatt-hours (kWh). The display is continuous and does not require any button presses for basic reading.

Close-up of QOLTEC 50900 LCD display showing energy reading

Mufananidzo 6.1: Pedyo-kumusoro view of the LCD display showing an example energy reading in kWh.

6.2 Pulse Output

The meter features a pulse output (400imp/kWh) which can be used to connect to external monitoring systems for remote data collection. Refer to the external system's documentation for connection details.

7. Kuchengeta

The QOLTEC 50900 energy meter is designed for maintenance-free operation under normal conditions.

8. Kugadzirisa matambudziko

If you encounter issues with your QOLTEC 50900 meter, refer to the following common problems and solutions:

DambudzikoZvinogona KukonzeraSolution
No display/Meter not powering onNo power supply; Incorrect wiring; Blown fuse in circuitCheck power supply to the meter. Verify wiring connections. Check circuit breaker/fuse.
Incorrect energy readingIncorrect wiring; Faulty meterVerify wiring connections against the diagram. If wiring is correct, contact support.
Pulse output not workingIncorrect connection to external system; Faulty meterCheck pulse output wiring to the external system. Consult external system's manual. If issue persists, contact support.

If the problem persists after attempting these solutions, please contact Qoltec customer support.

9. Warranty uye Tsigiro

Qoltec products are manufactured to high-quality standards. For warranty information and technical support, please refer to the warranty card included with your product or visit the official Qoltec website. Chengeta risiti rako rekutenga seumboo hwekutenga.

Related Documents - 50900

Preview Yambiro Yekuchengetedza Yekushandisa: Qoltec DIN Rail Magetsi Ekushandisa Mamita (TUYA)
Yakazara yambiro yekuchengetedza uye kungwarira kwekuisirwa, kushandiswa, kugadzirisa, uye kuchengetedza kweQoltec DIN njanji magetsi ekushandisa metres (TUYA) kuve nechokwadi chekuchengetedzwa kwemushandisi uye hupenyu hurefu hwechigadzirwa, zvinoenderana nemirairo yeEU.
Preview Qoltec DIN Rail Electricity Consumption Meter Safety Warnings and Precautions
Comprehensive safety warnings and precautions for Qoltec DIN rail electricity consumption meters, covering electrical risks, overloading, overheating, misuse, environmental factors, maintenance, and emergency procedures.
Preview Qoltec DIN Rail (TUYA) Elektriarvesti Ohutusjuhised
Täielikud ohutusjuhised ja ettevaatusabinõud Qoltec DIN Rail (TUYA) tüüpi elektriarvestite paigaldamiseks, kasutamiseks ja hooldamiseks. Tootja: NTEC sp. z o.o.
Preview Qoltec 50882 Single-phase Smart Energy Meter with Wi-Fi - Operating Instructions
Operating instructions for the Qoltec Model 50882, a single-phase smart energy meter with Wi-Fi for DIN rail mounting. Features include remote monitoring, kWh measurement, and compliance with industry standards.
Preview Qoltec Three Phase Smart Din Rail Energy Meter wi-fi User Manual
User manual for the Qoltec Three Phase Smart Din Rail Energy Meter wi-fi with 7 modules, model 50883. Includes technical parameters, dimensions, connection instructions, and warranty information.
Preview Qoltec DIN Rail Energy Meter (TUYA) Chengetedzo uye Mashandisiro Mazano
Yakakwana kuchengetedza kuchengetedza uye nhungamiro yekushandisa yeQoltec DIN Rail Energy Meters (TUYA). Dzidza nezve njodzi dzemagetsi, njodzi dzakawandisa, kupisa, kuisirwa kwakaringana, kugadzirisa, uye nzira dzekukurumidzira kuti uve nechokwadi chekuchengetedza uye kwakaringana mashandisiro emagetsi.