1. Safety Information
Please read and understand this entire manual before attempting to assemble, operate, or install the product. Failure to do so could lead to electric shock, fire, or other injuries that could be fatal or cause serious damage.
- YAMBIRO: Ngozi yemagetsi. Bvisa magetsi pafiyuzi kana dunhu rinopwanya usati waisa kana kusevhisi.
- This fixture is intended for installation in accordance with the National Electrical Code (NEC) and local code specifications. If you are not familiar with these codes, a qualified electrician should perform the installation.
- Usaise chinhu ichi panzvimbo dzinobvira moto nyore nyore.
- Ita shuwa kuti zvese zvinongedzo zvakachengeteka uye zvakavharirwa nemazvo.
- Usatarise zvakananga mu LED mwenje sosi.
2. Package Zviri mukati
Tarisa kuti zvese zvirimo zviripo usati watanga kuisa.
- LED Flood Light Fixture (1)
- Mounting Hardware Kit (1)
- Bhuku reMirayiridzo (1)
3. Zvinotsanangurwa
| Tsanangudzo | Value |
|---|---|
| Model Number | 17000207 |
| Simba Source | Hardwired |
| Wattage | 32 Watts |
| Kupenya | 3200 Lumens |
| Rudzi Tembiricha | 4000 Kelvin (Daylight White) |
| Motion Yekuona Nzvimbo | 240 degrees, up to 50 ft (15 m) |
| Material | Plastiki |
| Indoor / Outdoor Kushandiswa | Kunze |
| Mvura Resistance Level | Mvura Inodzivirira |
| Dimensions (L x W x H) | 7" x 12" x 8.4" |
| Warranty | Waranti yemakore maviri yemugadziri |

Image: Product dimensions for planning installation space.
4. Setup uye Kuiswa
This flood light is hardwired and requires connection to your home's electrical system. If you are not comfortable with electrical wiring, it is recommended to consult a qualified electrician.
4.1 Mounting Sarudzo
The fixture offers dual mounting capabilities, allowing for installation on a wall or under an eave. The canopy can be rotated to accommodate the desired position.

Image: Wall mount and eave mount installation options.
4.2 Matanho ekuisa
- Dzima Simba: Before starting, ensure the power to the installation area is turned off at the circuit breaker or fuse box.
- Install Mounting Bar: Secure the mounting bar onto the junction box.
- Isa Mounting Plate: Attach the mounting plate to the mounting bar.
- Wire Connections: Connect the fixture's wires to your home's electrical wires according to local codes (typically black to black, white to white, and ground to ground). Use wire nuts to secure connections.
- Batanidza Fixture: Secure the flood light fixture to the mounting plate using the center bolt.
- Chisimbiso: Apply weather-resistant sealant around the mounting plate to prevent water intrusion.
- Dzosera Simba: Once installation is complete and secure, restore power to the circuit.

Mufananidzo: Gwaro rekuisa nhanho nhanho.
5. Operating Instructions
The Globe Electric 17000207 flood light features motion activation and adjustable settings for optimal performance.
5.1 Motion Activation
The integrated motion sensor detects movement within a 240-degree zone, up to 50 feet (15 meters) away. The light will activate when motion is detected within this range.

Image: Motion detection zone illustration.
5.2 MotionBright™ 2-Level Lighting
This feature provides constant low ambient lighting when no motion is detected, and automatically switches to full brightness when motion is sensed, enhancing security and saving energy.

Image: MotionBright feature demonstrating low and full brightness modes.
5.3 Kugadzirisa Zvirongwa
The motion sensor unit has adjustable dials to customize the light's behavior:
- Nenguva: Adjusts how long the light stays on after motion is detected (1, 5, or 20 minutes, or Test mode).
- Sens (Sensitivity): Controls the range and sensitivity of the motion sensor (Low, Med, High).
- Kupenya: Adjusts the overall brightness of the light (Low, High).
- MotionBright: Selects the operating mode (OFF, Dusk to Dawn, Hour).

Image: Control dials for adjusting light settings.
5.4 Adjusting Lamp Misoro
Iwo matatu LED lamp heads are independently adjustable, allowing you to direct the light precisely where needed for optimal coverage.

Image: Adjustable lamp heads for directing light.
6. Kuchengeta
This LED flood light is designed for minimal maintenance.
- Kuchenesa: Kuti uchenese chinhu chacho, iva nechokwadi chekuti magetsi adzima. Pukuta nechinhu chakapfava, damp jira. Usashandise abrasive cleaners kana solvents.
- MaODs: The integrated LED lights are not user-replaceable. Do not attempt to open the lamp misoro.
- Sensor: Keep the motion sensor lens clean and free from obstructions (e.g., dirt, spiderwebs) to ensure proper operation.
7. Kugadzirisa matambudziko
If you experience issues with your flood light, refer to the following common problems and solutions:
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Chiedza hachibatidze. | No power, faulty wiring, sensor blocked, incorrect settings. | Check circuit breaker. Verify wiring connections. Clear sensor lens. Adjust 'On Time' or 'Sens' settings. |
| Chiedza chinoramba chiripo. | Continuous motion detected, 'On Time' set too long, 'MotionBright' setting. | Ensure no constant motion in detection zone. Adjust 'On Time' to a shorter duration. Check 'MotionBright' setting (e.g., if set to 'Dusk to Dawn'). |
| Kufamba hakuna kuonekwa nenzira yakavimbika. | Sensor blocked, sensitivity too low, incorrect angle. | Clear sensor lens. Increase 'Sens' setting. Adjust sensor angle for optimal coverage. |
| Chiedza chinopenya. | Loose wiring connection, power fluctuations. | Check all wiring connections for tightness. Consult an electrician if power fluctuations are suspected. |
8. Warranty uye Tsigiro
This Globe Electric product is backed by a Waranti yemakore maviri yemugadziri kubva pazuva rekutenga. Iyi waranti inovhara kukanganisa mune zvigadzirwa uye magadzirirwo pasi pekushandiswa kwakajairwa.
For warranty claims, technical assistance, or further inquiries, please contact Globe Electric customer support. Keep your proof of purchase for warranty validation.
Kuti uwane rumwe ruzivo, shanya iyo Globe Electric Store on Amazon.