KKnoon FY128

KKnoon Digital Multimeter (Model FY128) User Manual

Intelligent Electrical Tester with Backlit LCD

1. Nhanganyaya

This manual provides detailed instructions for the safe and effective use of your KKnoon Digital Multimeter, specifically focusing on the FY128 model. This compact and intelligent electrical tester is designed for accurate measurements of various electrical parameters, making it suitable for professionals, educational institutions, and home users. It adheres to the safety requirements of the International Electrotechnical Safety Standard (IEC-61010) for electronic measuring instruments.

The multimeter features a 5999-count backlit LCD for clear readings, along with functions for AC/DC voltage, resistance, frequency, continuity, live wire checking, and Non-Contact Voltage (NCV) kuonekwa.

KKnoon Digital Multimeter FY128 front view

Mufananidzo 1: Mberi view of the KKnoon Digital Multimeter (Model FY128) showing the display and control buttons.

2. Safety Information

To ensure safe operation and prevent damage to the meter, please read and follow all safety instructions carefully. Improper use can result in electric shock or damage to the instrument.

  • Always verify the meter's functionality before use by testing a known voltage kana kwazvino kwabva.
  • Usapfuure huwandu hwemapoinzi hunotsanangurwa pachiyero chega chega.
  • Ensure test leads are in good condition, free from cracks or damaged insulation, before connecting them to any circuit.
  • Never use the meter if it appears damaged or if the casing is open.
  • Chenjerera zvakanyanya paunenge uchishanda nevoltages pamusoro pe30V AC RMS, 42V peak, kana 60V DC. Aya voltages inokonzeresa njodzi.
  • Remove test leads from the circuit before changing functions or ranges.
  • Tsiva mabhatiri ipapo ipapo kana chiratidzo chebhatiri chidiki chaonekwa kuti uve nechokwadi chekuti bhatiri racho rakanyorwa nemazvo.
  • Usashandise mita iyi munzvimbo dzine gasi rinoputika, utsi, kana guruva.

3. Zvigadzirwa zveChigadzirwa

The KKnoon Digital Multimeter offers a range of features designed for convenience and accuracy:

  • Multi-Functionality: Zviyero AC/DC Voltage, Resistance, Frequency, Continuity, Live Wire Checking, and NCV (Non-Contact Voltaguye).
  • Two Measurement Modes:
    • Auto Identification: Automatically detects and measures AC/DC voltage, frequency, resistance, and continuity.
    • Manual Switch: Allows selection of specific functions including AC/DC voltage, frequency, resistance, continuity, diode, capacitance (FY129C only), and LIVE NCV.
  • Data Hold: Lock the current measurement reading on the display with a single button press.
  • Yakakura LCD Ratidza: Provides clear and easy-to-read values with a 5999-count resolution.
  • Flashlight & Screen Backlight: Inowedzera kuonekwa mumamiriro epasi-chiedza.
  • Compact Design with Bracket: Portable and includes a built-in support bracket for hands-free operation.
  • Kutevedzera Kuchengetedzwa: Designed and produced according to IEC-61010 safety standards.
Large screen of the digital multimeter highlighting resistance, frequency, continuity, and live wire checking functions

Figure 2: The multimeter's large LCD display clearly shows various measurement functions.

Digital multimeter with its support bracket extended, standing on a surface with test leads connected

Figure 3: The integrated support bracket allows for convenient hands-free use.

4. Package Zviri mukati

Paunenge wavhura pasuru yako, ndapota simbisa kuti zvinhu zvese zvakanyorwa pazasi zviripo uye mune zvakanaka:

  • 1 x KKnoon Digital Multimeter (Model FY128)
  • 1 x Pair yeMuedzo Inotungamira (Dzvuku uye Nhema)
  • 1 x Bhuku reMushandisi (Chirungu)

5. Setup

5.1 Kuiswa kwebhatiri

The multimeter requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:

  1. Ensure the multimeter is powered off and test leads are disconnected.
  2. Tsvaga chivharo chebhatiri kuseri kwemudziyo.
  3. Shandisa screwdriver kuvhura kamuri yebhatiri.
  4. Insert two 1.5V AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Tsiva chivharo chekamuri yebhatiri uye chengetedza nescuru.

5.2 Kubatanidza Miedzo Inotungamira

Multimeter inouya nemidziyo miviri yekuyedza (tsvuku nenhema). Vabatanidze seizvi:

  • Insert the black test lead into the 'COM' (Common) input jack.
  • Insert the red test lead into the 'INPUT' jack for most measurements (Voltage, Resistance, Frequency, Continuity, Diode, Capacitance).
Diagram showing the labeled parts of the digital multimeter, including input jacks and buttons

Figure 4: Labeled diagram of the multimeter's functions and input jacks.

6. Operating Instructions

6.1 Simba On/Kudzima

Dzvanya bhatani remagetsi dzvuku (Simba On bhatani) to turn the multimeter on or off. The device features an auto-shutdown function to conserve battery life after a period of inactivity.

6.2 Measurement Modes

The multimeter offers two primary measurement modes:

Image illustrating the two measurement modes: Auto identification and Manual Switching

Figure 5: The multimeter supports both auto identification and manual switching modes.

  • Auto Identification Mode: When powered on, the meter defaults to auto identification. In this mode, it automatically detects and measures AC/DC voltage, frequency, resistance, and continuity. Simply connect the test leads to the circuit, and the meter will display the relevant measurement.
  • Manual Switch Mode: To access specific functions not covered by auto identification or to manually select a range, press the 'NCV/LIVE' button (or other function buttons if available on your specific model, e.g., FY129C for Diode/Capacitance). This allows you to cycle through AC/DC voltage, frequency, resistance, continuity, LIVE, and NCV.

6.3 Kuyera AC/DC Voltage

  1. Connect the black test lead to the 'COM' jack and the red test lead to the 'INPUT' jack.
  2. If in auto identification mode, the meter will automatically detect voltage. If in manual mode, select the appropriate AC or DC voltage function.
  3. Batanidza tambo dzekuedza dzakafanana pakati pechikamu kana dunhu rinofanira kuyerwa.
  4. Verenga bhukutage kukosha pane LCD kuratidza.

6.4 Kuyera Kupokana

  1. Ita shuwa kuti dunhu rabviswa simba risati rayera kuramba.
  2. Connect the black test lead to 'COM' and the red test lead to 'INPUT'.
  3. If in auto identification mode, the meter will automatically detect resistance. If in manual mode, select the resistance function (Ω).
  4. Connect the test leads across the component whose resistance you wish to measure.
  5. Verenga kukosha kwekupikisa pane LCD kuratidza.

6.5 Kuyera Frequency

  1. Connect the black test lead to 'COM' and the red test lead to 'INPUT'.
  2. If in auto identification mode, the meter will automatically detect frequency. If in manual mode, select the frequency function (Hz).
  3. Connect the test leads to the circuit where frequency is to be measured.
  4. Verenga frequency kukosha paLCD kuratidza.

6.6 Kuenderera mberi Muedzo

  1. Iva nechokwadi chekuti dunhu harina simba.
  2. Connect the black test lead to 'COM' and the red test lead to 'INPUT'.
  3. If in auto identification mode, the meter will automatically detect continuity. If in manual mode, select the continuity function (★)).
  4. Touch the test leads to the two points of the circuit or component you want to test.
  5. A continuous beep indicates a low resistance path (continuity). The display will show the resistance value.

6.7 Live Wire Checking

This function helps identify live AC wires.

  1. Connect the black test lead to 'COM' and the red test lead to 'INPUT'.
  2. Press the 'NCV/LIVE' button until 'LIVE' is indicated on the display.
  3. Insert the red test lead into the socket or touch it to the wire you suspect is live.
  4. The meter will beep and the display will indicate 'LIVE' if a live wire is detected.
Digital multimeter performing live wire checking on an electrical outlet

Figure 6: Using the multimeter for live wire detection.

6.8 NCV (Asingabatike Voltage) Muedzo

Basa reNCV rinobvumira kuona AC voltage pasina kuonana kwakananga.

  1. Press the 'NCV/LIVE' button until 'NCV' is indicated on the display.
  2. Bring the top front part of the multimeter close to the wire or electrical outlet.
  3. The meter will beep and the NCV indicator on the display will illuminate or increase in intensity as it detects AC voltage.
Digital multimeter performing NCV test near an electrical outlet, showing a blue glow indicating detection

Mufananidzo 7: Bhuku Risingabatanidzwitage (NCV) detection in progress.

6.9 Data Bata Basa

To freeze the current reading on the display, press the 'HOLD' button. Press it again to release the hold and resume live measurements.

6.10 Flashlight & Backlight

Press the flashlight button (🔦) to turn on the built-in flashlight. Long press the 'HOLD' button to activate the screen backlight for improved visibility in dark environments.

7. Kuchengeta

7.1 Kutsiviwa kwebhatiri

When the low battery indicator appears on the display, replace the batteries as described in Section 5.1. Always use new 1.5V AAA batteries.

7.2 Kuchenesa

Kuti uchenese multimeter, pukuta bhokisi racho nekushambadziraamp cloth and a mild detergent. Do not use abrasives or solvents. Ensure the device is completely dry before use.

7.3 Kuchengeta

If the multimeter is not used for an extended period, remove the batteries to prevent leakage and corrosion. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Kugadzirisa matambudziko

Kana ukasangana nematambudziko ne multimeter yako, tarisa matambudziko akajairika nemhinduro dzinotevera:

DambudzikoZvinogona KukonzeraSolution
Hapana kuratidza kana dim kuratidzaMabhatiri akaderera kana akafa; Kuisa bhatiri zvisirizvoTsiva mabhatiri; Tarisa polarity yebhatiri
Kurava kusina kururamaLow batteries; Damaged test leads; Incorrect function selectedReplace batteries; Inspect/replace test leads; Select correct measurement function
Kuedza kuenderera mberi hakunzwi ruzhaOpen circuit; High resistance; Incorrect functionEnsure circuit is closed; Check for breaks; Select continuity function
Meter haipindureFrozen display (Data Hold); Internal faultPress 'HOLD' button to release; Contact customer support if issue persists

9. Zvinotsanangurwa

The following specifications apply to the KKnoon Digital Multimeter Model FY128 (and FY128C, unless specified for FY129C):

Digital multimeter with dimensions labeled: 123mm (4.84in) length, 61mm (2.40in) width, 24mm (0.94in) thickness

Figure 8: Physical dimensions of the KKnoon Digital Multimeter.

ParameterSpecification (FY128/FY128C)Specification (FY129C - if different)
AC Voltage1V~500V, ±(1.5%+3)0.8V~500V, ±(1.5%+5)
DC Voltage0.5V~500V, ±(1.2%+5)0.8V~500V, ±(1.2%+5)
Resistance30Ω~10000KΩ, ±(2%+5)30Ω~60000KΩ, ±(2%+5)
Frequency40Hz~1000Hz, ±(2.5%+5)10Hz~6000Hz, ±(2.5%+5)
CapacitanceN/A6nf~60000µf, ±(2.5%+5)
TembirichaN/A-20℃~1000℃, ±(5%+4)
Ambient TemperatureN/A0℃~70℃
DiodeAihwaEhe
ContinuityEheEhe
NCVEheEhe
Live Wire CheckingEheEhe
Auto ShutdownEheEhe
Magetsi2 * 1.5V AAA batteries (Not included)2 * 1.5V AAA batteries (Not included)
Chinhu Saizi123 * 61 * 24mm / 4.84 * 2.40 * 0.94in123 * 61 * 24mm / 4.84 * 2.40 * 0.94in
Item Weight113g / 3.98oz113g / 3.98oz

10. Warranty uye Tsigiro

For warranty information or technical support, please refer to the product packaging or contact your retailer. Keep your purchase receipt as proof of purchase. For general inquiries, you may visit the KKnoon brand page on Amazon.

Related Documents - FY128

Preview Mastfuyi FY128/FY128C/FY129C Smart Digital Multimeter User Manual
User manual for the Mastfuyi FY128, FY128C, and FY129C handheld digital multimeters. Features include 5999 counts, large LCD, NCV, Live wire detection, capacitance, frequency, temperature measurement, and overload protection. Compliant with IEC-61010 standards.