Elation Professional 1500IP-II

Bhuku reMushandisi weElation Professional Magmatic Magma Fog 1500IP-II Fog Machine

Model: 1500IP-II | Brand: Elation Professional

1. Nhanganyaya

This manual provides essential instructions for the safe and efficient operation, setup, maintenance, and troubleshooting of your Elation Professional Magmatic Magma Fog 1500IP-II Fog Machine. Please read this manual thoroughly before operating the device to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

The Magma Fog 1500IP-II is a high-performance, 1500W water-based fog machine designed for professional applications. It features an IP67 rating, making it suitable for outdoor use, and offers a maximum output of 60,000 cubic feet per minute (CFM). Control options include an onboard LCD touchscreen and DMX-512/RDM.

Magmatic Magma Fog 1500IP-II Fog Machine, front-side view

Mufananidzo 1.1: Kumberi-kurutivi view of the Magmatic Magma Fog 1500IP-II Fog Machine, showcasing its robust design and integrated fluid tank.

2. Safety Information

Always observe the following safety precautions to reduce the risk of electrical shock, fire, or personal injury.

Mberi view of Magmatic Magma Fog 1500IP-II with burn hazard warning

Mufananidzo 2.1: Mberi view highlighting the burn hazard warning label near the fog output nozzle. Always observe this warning.

3. Chigadzirwa Pamusoroview

The Magma Fog 1500IP-II is engineered for reliability and performance. Key components include:

Rear view of Magmatic Magma Fog 1500IP-II showing control panel and connections

Mufananidzo 3.1: Kumashure view of the unit, displaying the LCD touchscreen control panel, power input, DMX connections, and remote input.

4. Setup

4.1 Kusunungura

  1. Carefully remove the fog machine from its packaging.
  2. Inspect the unit for any signs of damage during shipping. Contact your dealer immediately if damage is found.
  3. Chengeta paki yekutanga kuti uiendese kana kuichengeta mune ramangwana.

4.2 Fluid Tank Installation and Filling

  1. Locate the fluid tank compartment on the top of the unit.
  2. Remove the empty fluid tank.
  3. Zadza tangi ne Magmatic brand water-based fog fluid only. Using other fluid types may damage the unit and void the warranty.
  4. Securely replace the fluid tank, ensuring the fluid hose is properly submerged and connected.

4.3 Simba Connection

  1. Connect the supplied IP65 locking power cable to the power input on the rear of the unit.
  2. Connect the other end of the power cable to a suitable grounded electrical outlet (120V, 60Hz).

4.4 DMX Connection (Sarudzo)

  1. For DMX control, connect a 5-pin DMX cable from your DMX controller to the DMX IN port on the fog machine.
  2. To daisy-chain multiple units, connect a DMX cable from the DMX OUT port of the first unit to the DMX IN port of the next unit.
  3. Ensure all DMX cables are IP65 rated for outdoor use if applicable.

4.5 Kuiswa

The unit includes a hanging bracket for truss mounting. Ensure the mounting surface or truss system can safely support the weight of the unit (74.3 lbs / 33.7 kg) and any accessories. Use appropriate clamps and safety cables (not included) for secure installation.

5. Operating Instructions

5.1 Powering On and Warm-up

  1. After connecting power, the unit will begin its initial warm-up sequence.
  2. The thermally protected heat exchanger requires approximately 14 minutes to reach optimal operating temperature.
  3. The LCD touchscreen will display the warm-up status. The unit is ready for operation once the status indicates 'Ready'.

5.2 Onboard LCD Touchscreen Control

The intuitive LCD touchscreen allows direct control over various functions:

5.3 DMX-512 and RDM Control

The Magma Fog 1500IP-II supports DMX-512 and RDM (Remote Device Management) for integration into professional lighting and effects systems. Refer to the DMX chart in the appendix (if provided separately) for specific channel assignments and control values. RDM allows for remote configuration and monitoring of the device.

5.4 Kudzora Kure Kwesarudzo

The unit is compatible with optional wired and wireless remote controls (sold separately). Connect the remote to the 'REMOTE IN' port on the rear of the unit. Consult the remote control's manual for specific operating instructions.

6. Kuchengeta

Regular maintenance ensures optimal performance and extends the lifespan of your fog machine.

6.1 Kuchenesa

6.2 Fluid Handling and Storage

7. Kugadzirisa matambudziko

This section addresses common issues you might encounter. If a problem persists, contact qualified service personnel.

DambudzikoZvinogona KukonzeraSolution
Hapana mhute inobudaNo power; insufficient warm-up; empty fluid tank; clogged nozzle/pumpCheck power connection; wait for 'Ready' status; refill fluid tank; clean nozzle/run cleaning solution.
Weak fog outputLow fluid level; partial clog; incorrect fluid type; low operating temperatureRefill fluid; run cleaning solution; ensure correct fluid; allow full warm-up.
Kudzora kweDMX hakusi kushandaIncorrect DMX address; faulty DMX cable; DMX controller issueVerify DMX address on unit and controller; test DMX cable; check DMX controller settings.
Chikamu hachibatikeNo power from outlet; faulty power cable; internal fuse blownCheck power source; test power cable; consult service technician for fuse replacement.

8. Zvinotsanangurwa

Detailed technical specifications for the Magmatic Magma Fog 1500IP-II.

FeatureTsanangudzo
Item Model NumberMSF047
Kushandisa Simba1500W
Output Volume60,000 CFM (cu ft/min)
Nguva yekudziyaAnenge maminitsi makumi maviri
Fluid Consumption Rate6.76 oz (200 ml/min)
Fluid Tank Capacity5 Marita (1.32 marita)
KudzoraOnboard LCD Touchscreen, DMX-512, RDM, Optional Wired/Wireless Remote
IP RatingIP67
Dimensions (L x W x H)25.5 x 14.6 x 16.2 inches (64.8 x 37.1 x 41.1 cm)
Item Weight74.3 makirogiramu (33.7 kg)
Housing MaterialAruminiyamu Inogara

9. Warranty uye Tsigiro

For warranty information and technical support, please refer to the official Elation Professional websaiti kana kubata mutengesi wako ane mvumo. Chengetedza risiti yako yekutenga sehumbowo hwekutenga kwezvichemo zvewaranti.

Elation Professional Customer Support: Kuti uwane rubatsiro, shanya www.elationlighting.com/support kana kubata muparidzi wenzvimbo yako.

Related Documents - 1500IP-II

Preview Elation Artiste Mondrian User Manual - Professional Lighting Guide
Yakazara mushandisi bhuku reElation Artiste Mondrian nyanzvi yekuvhenekesa mwenje. Inovhara kuisirwa, mashandiro, chengetedzo, DMX kudzora, uye maratidziro ekuita kwakaringana.
Preview Bhuku reMushandisi weElation FUZE PFX Moving Head Lighting Fixture
Bhuku rekushandisa rakakwana reElation FUZE PFX moving head lighting fixture, rinofukidza kuiswa, mashandiro, kuchengetedzeka, DMX control, marongero esystem, uye kugadzirisa.
Preview Elation CuePix Panel Mushandisi Manual: Kuisirwa, DMX Kudzora & Zvinotsanangurwa
Yakazara mushandisi bhuku reElation CuePix Panel yekuvhenekesa mwenje. Inovhara kuisirwa, DMX setup, tekinoroji yakatarwa, uye kugadzirisa kwehunyanzvi stage uye chiitiko chiedza.
Preview Elation Proteus Excalibur User Manual - Professional Moving Head Lighting Fixture
Yakazara mushandisi bhuku reElation Proteus Excalibur nyanzvi inofamba musoro mwenje mwenje. Inovhara kuisirwa, kushanda, nhungamiro yekuchengetedza, DMX kudzora, kugadzirisa, uye zvakatemwa.
Preview Elation Pulse Panel FX Mushandisi Manual
Iri bhuku remushandisi rinopa gwara rakazara reElation Pulse Panel FX, inyanzvi IP65 yakayerwa mwenje chigadziriso. Iyo inovhara yakadzama yekuisa maitiro, maitiro ekushandisa, system menyu navigation, DMX hunhu kune dzakasiyana siyana chiteshi modhi, dhairekitori rekugadzirisa, uye tekinoroji maratidziro ekushandisa zvakanyanya uye chengetedzo.
Preview Elation KL PAR FC IP User Manual: Installation, Operation, and Safety Guide
Comprehensive user manual for the Elation KL PAR FC IP professional lighting fixture. Covers installation, operation, DMX control, safety guidelines, and specifications for reliable performance in various environments.