The BEA Falcon is a sophisticated unidirectional motion sensor engineered to optimize the performance of automatic industrial doors. This sensor is designed to detect various targets and can be configured to filter out people, allowing for vehicle-only detection. This capability helps reduce door closing cycles by ignoring cross-traffic, leading to energy savings and improved operational efficiency.

The Falcon XL model, specifically, is suitable for mounting heights between 2 meters and 3.5 meters, providing a typical detection area of 4 x 2 meters. Its robust design ensures immunity against vibrations and environmental interferences, making it ideal for demanding industrial environments.

BEA Falcon XL Industrial Door Sensor

Mufananidzo 1: Mberi view of the BEA Falcon XL Industrial Door Sensor. This image shows the compact, black housing of the sensor, designed for robust industrial applications.

2. Key Features

3. Zvigadzirwa zveChigadzirwa

The BEA Falcon sensor consists of several key components designed for easy installation and reliable operation. Refer to the diagram below for an overview of the main parts.

BEA Falcon XL Sensor Components Diagram

Figure 2: Diagram illustrating the main components of the BEA Falcon XL sensor.

  1. Push Buttons: For basic function adjustments.
  2. Front Face: The primary detection surface.
  3. Radar Antenna: Emits and receives microwave signals.
  4. Angle Indication: Visual indicator for tilt angle adjustment.
  5. Bracket: Mounting hardware for secure installation.
  6. Cable: For power and signal connection.

4. Setup uye Kuiswa

The BEA Falcon XL sensor is designed for straightforward installation. Proper mounting and wiring are crucial for optimal performance and safety. It is recommended that installation be performed by qualified personnel.

4.1 Mafungiro ekukwira

4.2 Kubatanidza waya uye Simba

4.3 Magadzirirwo ekutanga

Basic functions can be adjusted using the integrated push buttons or a compatible remote control. Refer to the detailed product manual (not provided in this summary) for specific programming steps for features like people filtering and cross-traffic filtering.

BEA Falcon XL Detection Field Diagram

Figure 3: Illustration of the detection fields for the BEA Falcon sensor in an industrial door application. This diagram shows how the sensor can differentiate between pedestrian and vehicle traffic, optimizing door operation.

5. Kushanda

Once properly installed and configured, the BEA Falcon XL sensor operates autonomously to detect motion within its defined field. The sensor's LED indicator provides visual feedback on its status.

5.1 Detection Mode

The sensor operates in motion detection mode. It identifies moving objects within its detection zone and triggers the door opening mechanism based on the configured parameters (e.g., presence of vehicles only).

5.2 LED zviratidzo

5.3 Kuvandudza Kuita

To ensure optimal performance, regularly verify that the detection field is clear of obstructions and that the sensor's lens is clean. The unidirectional detection and filtering capabilities contribute to efficient door operation and energy conservation.

6. Kuchengeta

The BEA Falcon XL sensor is designed for minimal maintenance due to its robust construction and IP65 rating. However, periodic checks are recommended to ensure continued optimal performance.

No user-serviceable parts are inside the sensor housing. Do not attempt to open or repair the unit yourself. Contact qualified service personnel for any repairs.

7. Kugadzirisa matambudziko

This section provides basic troubleshooting steps for common issues. For more complex problems, consult a qualified technician.

DambudzikoZvinogona KukonzeraSolution
Sensor not detecting motion.No power; obstructed detection field; incorrect sensitivity settings; sensor malfunction.Check power supply and connections. Clear any obstructions. Adjust sensitivity settings. If problem persists, contact support.
Door opens for unwanted traffic (e.g., pedestrians).People filter not activated or incorrectly configured; cross-traffic filter not active.Verify and adjust the people filter and cross-traffic filter settings using push buttons or remote control.
Chiratidzo che LED hachisi kuvhenekera.No power; faulty LED; internal issue.Check power supply. If power is present and LED remains off, the unit may require service.
Kuonekwa kwezviitiko panguva imwe chete.Loose wiring; environmental interference; sensor position shifted.Inspect wiring connections. Ensure sensor is securely mounted and not vibrating. Check for new sources of interference.

8. Zvinyorwa zveUnyanzvi

ParameterValue
Vadivelu Comedy TechnologyMicrowave Doppler radar
Transmitter Frequency24.150 GHz
Transmitter Radiated Power<20 dBm EIRP
Transmitter Power Density<5 mW/cm²
Detection ModeMotion
Detection Zone (FALCON XL)4 x 2 m (typical at 30° and field size 9)
Min. Kuziva Speed5cm/s
Mugovera Voltage12 V to 24 V AC ±10% (50 - 60 Hz); 12 V to 24 V DC +30% / -10%
Max Simba Kushandisa<2 W
Output RelayFree of potential change-over contact
Max. Contact Voltage30V AC / 42V DC
Max. Contact Current1A (inopikisa)
Max. Kuchinja Simba30 W
Akatungamirira SignalRed: detection state, parameter indication; Green: value indication
Mounting Height (FALCON XL)2 m - 3.5 m
Dhigirii rekudziviriraIP65 (IEC/EN 60529)
Temperature Range-30 °C kusvika +60 °C
Zviyero (L x H x W)127 mm x 102 mm x 96 mm
Tilt Angles0° to 180° vertical
ZvishandisoABS and Polycarbonate
Kurema400 g
Cable Length10 kana 15 m

9. Safety Information

Always observe the following safety precautions during installation, operation, and maintenance of the BEA Falcon XL sensor:

10. Warranty uye Tsigiro

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your authorized BEA distributor. Keep your purchase receipt as proof of purchase.

Related Documents - 1PC BEA FALCON XL(2-3.5m)

Preview FALCON EX Motion Sensor with Explosion-Proof Housing - User Guide
Comprehensive user guide for the BEA FALCON EX motion sensor with explosion-proof housing, covering technical specifications, installation, operation, settings, and troubleshooting.
Preview Eagle Artek Unidirectional Kuvhura Sensor yeOtomatiki Doors - Mushandisi Gwaro & Matsanangudzo
Yakakwana mushandisi gwara reiyo BEA Eagle Artek Unidirectional Kuvhura Sensor. Inovhara kuisirwa, tekinoroji yakatarwa, marongero, kugadzirisa matambudziko, uye kutevedzera otomatiki magonhi masisitimu. Model SW 0100 uye kumusoro.
Preview Gwaro reVashandisi veBEA EAGLE ARTEK reSensor Yekuvhura Isingatungamirirwi
Gwaro rekushandisa rakakwana reBEA EAGLE ARTEK rinovhura magonhi nenzira imwe chete, rinosanganisira hunyanzvi, kuiswa, marongero, uye kugadzirisa matambudziko.
Preview FALCON EX Sensor de movimiento con carcasa a prueba de explosiones - Guía del Usuario
Guía del usuario detallada para el sensor de movimiento FALCON EX de BEA, Inc. Cubre descripción del producto, especificaciones técnicas, señales LED, uso del control remoto y botones, consejos de instalación, cableado, dimensiones del campo de detección, configuración, solución de problemas y cumplimiento.
Preview BEA IS40 / IS40 XL Motion and Presence Sensor User Manual
Comprehensive user manual for the BEA IS40 and IS40 XL motion and presence sensors, detailing technical specifications, installation, wiring, sensor angle adjustment, remote control operation, radar and air patterns, setup procedures, and troubleshooting for automatic industrial doors.
Preview BEA IXIO-DT1 Motion uye Kuvapo Sensor yeAutomatic Sliding Doors - Mushandisi Manual
Yakakwana dhairekitori yeBEA IIXIO-DT1 kufamba uye kuvapo sensor, kuvhara kuisirwa, kuseta, hunyanzvi hwekuita, uye kugadzirisa matambudziko kune otomatiki kutsvedza magonhi.