REFCO 3004145

GOBI II Universal Condensate Pump

Muenzaniso: 3004145

Bhuku reMirayiridzo

1. Nhanganyaya

The REFCO GOBI II Universal Condensate Pump is designed for efficient and quiet removal of condensate from air conditioning, HVAC, and dehumidifier systems. Suitable for systems ranging from 6,000 BTU/h to 120,000 BTU/h, this pump features a digital water sensor, universal voltage compatibility, and individually configurable flow rates, making it a versatile solution for various applications. This manual provides essential information for safe installation, operation, maintenance, and troubleshooting of your GOBI II pump.

REFCO GOBI II Universal Condensate Pump, assembled view

Mufananidzo 1.1: Yakaunganidzwa view of the GOBI II Universal Condensate Pump.

2. Safety Information

Ndapota verengai mirairo yese yekuchengetedza musati maisa uye maishandisa. Kukundikana kutevedzera mirairo iyi kunogona kukonzera kuvhunduka kwemagetsi, moto, kana kukuvara kwakanyanya.

  • Always disconnect power to the air conditioning unit and the pump before performing any installation, maintenance, or troubleshooting.
  • Installation must be performed by a qualified technician in accordance with all local and national electrical and plumbing codes.
  • Ensure the pump is installed in a location where it is protected from direct water spray and extreme temperatures.
  • Do not operate the pump with damaged cables or if it has been dropped or damaged.
  • This pump is designed for condensate water only. Do not use it for other liquids.
  • Chengeta vana nevanhu vasina mvumo kure nenzvimbo yekuisa.

3. Chigadzirwa Pamusoroview

The GOBI II pump system consists of several key components designed for reliable condensate removal.

Diagram showing GOBI II pump components and included accessories

Figure 3.1: GOBI II kit components and labeled diagram.

3.1. Zvikamu Zvinosanganisirwa:

  • Simba tambo
  • Alarm cable
  • Star tube and anti-siphon device
  • Screws (for mounting)
  • Zvikurisa anchors
  • Factory-installed alarm fuse
  • Zvisungo zvetambo

3.2. Zvinokosha:

  • Universal application for various AC systems.
  • High pumping capacity: 11 GPH (gallons per hour).
  • High discharge head: up to 65.6 ft.
  • Extremely quiet operation: less than 19 dB noise level.
  • Reliable digital water sensor, eliminating traditional float problems.
  • Demand-oriented control for optimized pumping capacity.

4. Setup uye Kuiswa

The GOBI II pump is designed for direct mounting under the air conditioner unit. Follow these steps for proper installation:

  1. Kukwidza: Secure the pump's wall back plate (component 9 in Figure 3.1) to a stable surface directly beneath the air conditioning unit using the provided screws and screw anchors. Ensure it is level.
  2. Pump Body Installation: Slide the pump body (component 1 in Figure 3.1) onto the mounted back plate until it clicks securely into place.
  3. Condensate Inlet Connection: Connect the condensate drain line from the air conditioning unit to the pump's inlet. Ensure a tight, leak-free connection.
  4. Kubatanidza Mutsetse Wekuburitsa Mvura: Connect the 1/4" discharge tube from the pump's outlet to your desired drain point. Install the provided anti-siphon device in the discharge line to prevent backflow and ensure proper pump operation. Ensure the discharge line rises vertically for at least 6 inches before running horizontally or downwards.
  5. Kubatanidza Magetsi: Connect the power cable to the pump and then to a suitable power supply (100-240 VAC, 50/60 Hz). Ensure all electrical connections are secure and comply with local electrical codes.
  6. Alarm Cable Connection (Optional but Recommended): Connect the alarm cable to the pump's alarm relay terminals and integrate it with your HVAC system's alarm circuit if desired. The alarm relay is interchangeable (NO or NC) and rated for 250VAC, 6.3A or 28VDC, 6.3A.
  7. Kuedza: Once all connections are made, restore power to the system. Pour a small amount of water into the air conditioner's drain pan to verify the pump activates and discharges water correctly. Check for any leaks.

5. Operating Instructions

The GOBI II condensate pump operates automatically based on the water level detected by its digital sensor. It will activate when condensate accumulates and shut off once the water is cleared.

5.1. Digital Sensor and Flow Control:

The integrated digital sensor (component 4 in Figure 3.1) precisely monitors the water level, ensuring the pump activates only when necessary. The pump's demand-oriented control adjusts the pumping capacity as needed, optimizing efficiency and minimizing noise.

5.2. Diagnostic LEDs:

The pump features a diagnostic LED (component 8 in Figure 3.1) to indicate its operational status.

Diagram showing diagnostic LEDs: green for normal operation, red for error

Figure 5.1: Diagnostic LED indicators.

  • Green Girazi: Indicates normal operation. The pump is powered and functioning correctly.
  • Dzvuku re LED: Indicates an error or alarm condition. Refer to the Troubleshooting section for possible causes.

6. Kuchengeta

Regular maintenance ensures the longevity and optimal performance of your GOBI II pump.

  • Cheki yemwedzi wega wega: Visually inspect the pump, inlet, and discharge lines for any blockages, kinks, or leaks. Ensure the pump housing is clean.
  • Kuchenesa Kwegore: Disconnect power to the pump and the AC unit. Carefully remove the pump body from the wall back plate. Clean the water tray (component 5 in Figure 3.1) and the digital sensor (component 4) to remove any sludge, mold, or debris. A soft brush and mild detergent can be used. Rinse thoroughly with clean water.
  • Kutsiva Sefa: The pump includes a replaceable filter (component 3 in Figure 3.1). Check its condition during annual cleaning and replace if it appears clogged or damaged.
  • Reassembly: After cleaning, reassemble all components, ensuring they are securely in place. Restore power and test the pump's operation.

7. Kugadzirisa matambudziko

If you encounter issues with your GOBI II pump, refer to the following table for common problems and solutions. Always disconnect power before attempting any inspection or repair.

DambudzikoZvinogona KukonzeraSolution
Pombi haimhanyeNo power; Clogged inlet/outlet; Faulty sensor; Motor issueCheck power supply; Clear blockages; Clean digital sensor; Contact support if issue persists.
Pombi inomhanya ichiendereraAnti-siphon device missing/incorrectly installed; Leak in discharge line; Sensor issueInstall/check anti-siphon device; Inspect discharge line for leaks; Clean sensor.
Mvura inofashukiraPump not running; Clogged lines; Pump capacity exceeded; Alarm not connectedSee "Pump does not run"; Clear blockages; Ensure system BTU/h is within pump's range; Connect alarm.
Red diagnostic LED is onError condition (e.g., high water alarm, pump fault)Check for blockages, ensure proper installation, and verify power. If the issue persists after checking, contact technical support.

8. Zvinotsanangurwa

Detailed technical specifications for the GOBI II Universal Condensate Pump.

ParameterValue
Max. Kuyerera Rate11 GPH (0.18 Gallons Per Minute)
Max. Discharge Head65.6 ft
Max. Suction Lift10 ft
Noise Level<19 dB(A)
Pump TypeDiaphragm type
Tube Diameter1/4 ″
Voltage100 - 240 VAC
Frequency50 / 60 Hz
Kushandiswa Kwemagetsi8 W
Dziviriro KirasiI
Alarm RelayInterchangeable NO or NC, rated 250VAC, 6.3A or 28VDC, 6.3A
Ingress DziviriroIP44
Cable Length5 ft
Operating Temperature Range41 - 104 °F (5 - 40 °C)
Tembiricha Yemvura Range41 - 104 °F (5 - 40 °C)
Storage Temperature Range-4 - 122 °F (-20 - 50 °C)
Item Weight2.59 makirogiramu
Package Dimensions13.66 x 12.8 x 2.6 inches

8.1. Capacity Curve:

The following graph illustrates the pump's capacity (flow rate) versus vertical lift/head pressure.

Graph showing GOBI II pump capacity in GPH and l/hr versus vertical lift/head pressure in feet and meters

Figure 8.1: GOBI II Capacity Curve.

9. Warranty

The manufacturer warranty for the GOBI II Universal Condensate Pump begins with the commissioning of the unit. Please refer to the warranty documentation included with your purchase for specific terms and conditions.

10. Tsigiro

For technical assistance, spare parts, or further inquiries, please contact your REFCO product supplier or visit the official REFCO websaiti yerutsigiro yekuonana ruzivo.

Related Documents - 3004145

Preview Gobi II Condensate Pombi Kuiswa uye Operation Manual
Yakakwana gwara reiyo REFCO Gobi II condensate pombi, inovhara kuisirwa, kushanda, kugadzirisa, uye kugadzirisa matambudziko eHVAC/R masisitimu.
Preview REFCO GOBI II Condensate Pombi: Kurumidza Kuisa Gwaro
Yepamutemo yekukurumidza gwara reiyo REFCO GOBI II condensate pombi (modhi 3004145). Inopa ruzivo rwakakosha pakuisirwa, kushanda, chengetedzo, uye gadziriso yekubvisa kwakaringana condensate muHVAC masisitimu.
Preview REFCO Gobi II Condensate Pombi Kuiswa uye Operation Manual
Gwaro rakazara kune REFCO Gobi II condensate pombi, inodonongodza kuisirwa, kushanda, kuchengetedzwa kwekuchengetedza, hunyanzvi hwekuita, uye kugadzirisa matambudziko. Zvimiro zvinosanganisira inogadziriswa yakanyarara modhi, diagnostic LED, USB yekubatanidza, uye yakakura application renji.
Preview REFCO Combi Universal Condensate Pump 3004146 Kuisa uye Technical Manual
Gwaro iri rinopa kuisirwa kwakazara, hunyanzvi hwekuita, gwara rekuchengetedza, uye ruzivo rwekugadzirisa dambudziko reREFCO Combi Universal Condensate Pump (Model 3004146).
Preview REFCO VAMP-F Condensate Pump Quick Guide
Gwaro rakapfupikiswa rekuisirwa, kushanda, uye kugadzirisa kweREFCO VAMP-F condensate pombi, yakagadzirirwa kubviswa kwakanaka kwe condensate kubva kuHVAC systems. Inosanganisira maitiro ehunyanzvi uye mirairo yekuchengetedza.
Preview REFCO VAMP-X Condensate Pump Instruction Manual
Iri bhuku rekuraira rinopa ruzivo rwakadzama nezve REFCO VAMP-X condensate pombi, inovhara zvirevo zvayo, kuisirwa, kushanda, kugadzirisa, mirairo yekuchengetedza, uye kugadzirisa matambudziko. Inowanikwa muChirungu, German, French, Italian, and Spanish.