Diversitech CP-22LPT

Asurity by Diversitech CP-22LPT Low Profile Condensate Pump User Manual

Model: CP-22LPT

Nhanganyaya

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Asurity by Diversitech CP-22LPT Low Profile Condensate Pump. This pump is designed to automatically evacuate condensate or water discharge from HVACR equipment, offering a vertical lift capability of up to 22 feet. Its low-profile design makes it suitable for installations in tight spaces.

Safety Information

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or death.

  • Njodzi Yemagetsi: Disconnect power before servicing. This unit operates on 110 Volts. Ensure all electrical connections comply with local codes.
  • Dambudziko reMvura: This pump handles water. Ensure proper drainage and prevent water damage.
  • Kuiswa: Install the pump in a location where it is accessible for maintenance and inspection.
  • Zvinotarisirwa Kushandiswa: Use this pump only for its intended purpose of evacuating condensate from HVACR equipment.
  • UL Yakanyorwa: This product is UL listed, meeting electrical and mechanical safety standards for water pumps.

Package Zviri mukati

Tarisa kuti zvinhu zvese zviripo usati watanga kuisa:

  • Asurity by Diversitech CP-22LPT Condensate Pump
  • 20 ft Clear Vinyl Tubing
  • 4 ft Safety Switch Wire (pigtail)

Product Overview

The Asurity CP-22LPT condensate pump features a compact design with advanced functionalities for reliable condensate removal.

Asurity CP-22LPT Condensate Pump with Clear Tubing

Mufananidzo 1: The Asurity CP-22LPT low profile condensate pump shown with the included clear vinyl tubing. The pump features a red base and a black motor housing with ventilation slots and an outlet port.

Asurity CP-22LPT Condensate Pump with Tubing and Safety Switch Wire

Mufananidzo 2: A kumusoro-pasi view of the Asurity CP-22LPT condensate pump, accompanied by the coiled clear vinyl tubing and the yellow safety switch wire. This image highlights all primary components included with the unit.

Side View of Asurity CP-22LPT Condensate Pump

Mufananidzo 3: A side perspective of the Asurity CP-22LPT condensate pump, illustrating its low-profile design. This view emphasizes the compact dimensions suitable for installation in confined spaces.

Zvinokosha:

  • LED Status Indicator Lights (Power, Run, Alarm)
  • Vibration Dampening System for quiet operation
  • Integrated Safety Switch with 4 feet of wire for air-handler shutdown
  • Yakaderera profile design for tight installations
  • Metal mounting tabs for secure installation
  • Four inlet holes (with 3 poly covers for unused ports)
  • Float switch and duckbill-style check valve

Setup uye Installation

Proper installation is crucial for the pump's performance and longevity. Ensure all local electrical and plumbing codes are followed.

  1. Kuiswa: Position the pump on a level surface near the HVACR unit. The low-profile design is ideal for tight spaces. Utilize the vibration dampening feet and metal mounting tabs for secure placement.
  2. Condensate Inlet Connection: Connect the condensate drain line from the HVACR unit to one of the pump's inlet holes. The pump has four inlet holes; seal any unused inlets with the provided poly covers.
  3. Kubatanidza Mutsetse Wekuburitsa Mvura: Connect the 20 ft clear vinyl tubing to the pump's discharge outlet. Route the tubing upwards, ensuring it does not exceed the pump's 22 ft vertical lift capability, and then to a suitable drain point. Avoid kinks or sharp bends in the tubing. The integrated duckbill-style check valve prevents backflow.
  4. Kubatanidza Magetsi: Connect the pump to a dedicated 110V power supply. Ensure the power source is off before making connections.
  5. Safety Switch Connection: Connect the 4 ft safety switch wire (pigtail) to the air-handler's shutdown circuit. This feature is designed to shut down the HVACR unit if the pump fails or the water level rises too high, preventing overflow. Refer to your HVACR unit's manual for specific wiring instructions for the safety switch.
  6. Kuedza: After installation, manually pour water into the pump's reservoir to verify proper operation. The pump should activate, discharge the water, and then shut off. Check for any leaks.

Operating Instruction

The Asurity CP-22LPT condensate pump operates automatically once properly installed and powered.

  • When condensate water enters the pump's reservoir and reaches a predetermined level, the internal float switch activates the pump.
  • The pump will then discharge the water through the connected vinyl tubing to the designated drain.
  • Once the water level drops, the float switch deactivates the pump.
  • Zviratidzo zve LED:
    • Pwr (Power): Illuminates when the pump is receiving electrical power.
    • Mhanya: Illuminates when the pump motor is actively discharging water.
    • Alrm (Alarm): Illuminates if the water level rises to the high-level alarm switch, indicating a potential issue and activating the safety shutdown circuit.

Maintenance

Regular maintenance ensures optimal performance and extends the life of your condensate pump.

  • Kuongorora Kwemwedzi: Check the pump reservoir for sludge, mold, or debris. Clean as necessary.
  • Kuchenesa: Disconnect power before cleaning. Remove the pump cover and clean the reservoir with a mild detergent and water. Ensure the float switch moves freely.
  • Mutsetse weKuburitsa Mvura: Inspect the vinyl tubing for blockages, kinks, or leaks. Clear any obstructions.
  • Inlet Ports: Ensure inlet ports are clear of debris.

Kugadzirisa matambudziko

Tarisa tafura inotevera kuti uwane matambudziko akajairika uye mhinduro dzawo.

Dambudziko Zvinogona Kukonzera Solution
Pombi haimhanye No power; Clogged inlet/outlet; Stuck float switch; Motor failure Check power supply; Clear blockages; Inspect/clean float switch; Contact support if motor fails
Pombi inomhanya ichienderera Stuck float switch; Leak in discharge line; Pump undersized for flow rate Inspect/clean float switch; Check for leaks; Verify pump capacity meets demand
Water overflow / Alarm LED on Pump failure; Clogged discharge line; Safety switch activated Check pump operation; Clear discharge line; Investigate cause of high water level
Kunyanya ruzha/vibration Debris in pump; Improper mounting; Worn motor bearings Clean pump; Ensure secure mounting; Contact support for motor issues

Zvinotsanangurwa

Feature Detail
Brand Diversitech (Asurity)
Model Number CP-22LPT
Voltage 110 Volts
Simba Source Corded Electric
Kusimudza Kwakanyanya 22 tsoka
Maximum Flow Rate 1.6 Maroni Paminiti
Product Dimensions 12"L x 6.75"W x 6"H
Item Weight 5.41 makirogiramu
Material Plastiki
Color Red Black
Inosanganisirwa Zvikamu Condensate Pump, 20ft clear vinyl tubing, 4ft safety switch wire (pigtail)
Certifications UL Yakanyorwa

Warranty uye Support

For warranty information or technical support, please contact Diversitech customer service. Keep your purchase receipt for warranty claims.

Mugadziri: Diversitech

Websaiti: www.diversitech.com

Contact: Tarisa kune mugadziri wacho websaiti yeruzivo rwazvino.

Related Documents - CP-22LPT

Preview Gwaro reKuisa uye Kushanda kwePombi yeCondensate yeDiversiTech
Gwaro iri rinopa mirairo yakadzama yekuisa, kushandisa, uye kuchengetedza mapombi eDiversiTech condensate (CP-22 series). Rinosanganisira matanho ekuchengetedza, zvirevo, zviri mukati mepakeji, kuisa nhanho nhanho, kugadzirisa matambudziko, uye ruzivo rwewarandi.
Preview Bhuku reKuisa uye Kushanda kweDiversiTech Condensate Pombi
Gwaro rakakwana rekuisa nekushandisa mapombi eDiversiTech condensate (CP-22, CP-22LP, CP-22T series). Rinosanganisira mirairo yekuchengetedza, zvirevo, matanho ekuisa, ruzivo rwekushanda, kugadzirisa matambudziko, uye ruzivo rwewarandi.
Preview Gwaro Rekuisa Pombi yeCondensate yeDiversiTech Plenum-Rated
Gwaro rakakwana rekuisa, kushanda, uye kugadzirisa mapombi eDiversiTech CP-22LP-P uye CP-22LP-230-P Plenum-Rated Condensate. Rinosanganisira yambiro dzekuchengetedza, zvirevo, mirairo yekuisa nhanho nhanho, mazano ekugadzirisa matambudziko, uye ruzivo rwewarandi.
Preview Hef-T-Bracket Installation Guide - 230-B2L
Mirayiridzo yekuisa uye zvirevo zveDiversiTech Hef-T-Bracket 230-B2L, bhuroko remadziro remayuniti emhepo inotonhodza.
Preview Gwaro rekuisa mabhureki emadziro eDiversitech HW-600 reMini Split Systems
Gwaro rakakwana rekuisa bracket remadziro reDiversitech HW-600, rakagadzirirwa kuisa mayuniti ekunze ekunze akapatsanurwa. Rinosanganisira runyorwa rwezvikamu, mirairo yekuungana, uye ruzivo rwakakosha rwekuchengetedza.
Preview DiversiTech ACB Series Wall Bracket Systems yeA/C Condensing Units
Matekinoroji ehunyanzvi uye nhungamiro yekumisikidza yeDiversiTech ACB yakatevedzana madziro bracket masisitimu, anosanganisira modhi ACB-30, ACB-36, ACB-42, uye ACB-48, yakagadzirirwa A/C condensing units.