Aiphone VM-RMVU

Bhuku reMirayiridzo yeAiphone VM-RMVU Residential Security Master Unit

Model: VM-RMVU

1. Nhanganyaya

This manual provides detailed instructions for the installation, operation, and maintenance of the Aiphone VM-RMVU Residential Fire Alarm Compatible Monitor Security Master Unit. Please read this manual thoroughly before using the product to ensure correct and safe operation. Keep this manual in a safe place for future reference.

2. Setup uye Kuiswa

The Aiphone VM-RMVU unit is designed for wall-mounted installation. Ensure proper power supply and network connections as described below.

2.1 Zvekunze View uye Mounting

Refer to the diagram below for the external dimensions and mounting details. The unit requires a compatible wall box for installation.

Aiphone VM-RMVU External View and Mounting Dimensions

Mufananidzo 1: External view of the Aiphone VM-RMVU unit with detailed mounting dimensions. This diagram illustrates the physical layout, including the location of the power switch, sensors, microphone, speaker, and various indicator lights. It also shows the dimensions for wall-mounted installation.

2.2 Wiring Connections

Follow the wiring diagram carefully to connect the master unit to power, entrance units, sub-units, and other security devices. The system supports both wired and wireless LAN connections.

Aiphone VM-RMVU Wiring Diagram

Mufananidzo 2: Comprehensive wiring diagram for the Aiphone VM-RMVU system. This diagram details connections for power, entrance units, monitor sub-units, wireless base stations, extension master units, gas/CO alarms, auxiliary alarm devices, call buttons, security set panels, and passive sensors. It also illustrates connections for internet apps, smartphones, and Amazon Alexa devices via wireless LAN.

Magetsi:

  • Connect the unit to an AC100V, 50/60Hz power source.
  • Ensure the power switch (located on the rear panel) is in the OFF position before connecting.

Network Connection:

  • The VM-RMVU supports wireless LAN (IEEE 802.11b/g/n) for connection to internet apps, smartphones, and Amazon Alexa devices.
  • Refer to the separate wireless LAN setup guide for detailed configuration instructions.

3. Operating Instructions

The Aiphone VM-RMVU features a 7-inch TFT LCD touch panel and intuitive buttons for various functions.

Aiphone VM-RMVU Front Panel Controls

Mufananidzo 3: Front panel of the Aiphone VM-RMVU showing the 7-inch LCD display and control buttons. Key buttons include EMERGENCY, POWER indicator, TALK, OFF, OPEN, and ALARM STOP. The model name 'AIPHONE VM-RMVU' is also visible below the screen.

3.1 Basic Mabasa

  • Batidza/Kudzima: Press the power switch on the rear panel to turn the unit on or off. The green POWER indicator will illuminate when on.
  • Kupindura Nhare: When an entrance unit calls, the display will show the caller. Press the TALK button to initiate a simultaneous call. The green TALK indicator will light up.
  • Kupedza Kufona: Press the DZIMA button to end a call. The red OFF indicator will light up briefly.
  • Kuvhura Madhoo: Panguva yekufona, pinda iyo Vhura button to unlock the connected door. The green OPEN indicator will light up.

3.2 Security and Alarm Functions

  • Emergency Button: Press the KUTANGA button in case of an emergency to trigger an alarm.
  • Alarm Stop: If an alarm sounds (e.g., fire, gas, security alert), press the ALARM MIRA button to silence it. The red ALARM STOP indicator will light up when an alarm is active.
  • Security Display: The security display unit provides visual indicators for Fire, Gas, and Security Alert statuses.

3.3 Touch Panel Operation

The 7-inch TFT LCD is a touch panel. Navigate through menus and settings by tapping on the screen icons and options. Refer to the on-screen guide for specific menu functions.

4. Kuchengeta

Regular maintenance ensures the longevity and optimal performance of your Aiphone VM-RMVU unit.

  • Kuchenesa: Use a soft, dry cloth to clean the unit's surface and display. Do not use abrasive cleaners or solvents.
  • Kuongorora: Periodically check all connections for security and ensure no cables are damaged.
  • Zvigadziriso zveSoftware: Tarisa mugadziri wacho website for any available firmware updates to ensure your unit has the latest features and security enhancements.

5. Kugadzirisa matambudziko

If you encounter issues with your Aiphone VM-RMVU unit, refer to the following common troubleshooting steps:

  • Hapana Simba: Ensure the power cable is securely connected and the power switch on the rear panel is ON. Check your circuit breaker.
  • Hapana Vhidhiyo/Odhiyo: Verify all wiring connections to entrance units and sub-units. Ensure network connectivity for wireless functions.
  • Alarm Malfunction: Check the status indicators on the security display unit. If the issue persists, contact customer support.
  • Touch Panel Unresponsive: Try restarting the unit by turning the power off and on. If the problem continues, contact support.

For more complex issues, please consult a qualified technician or Aiphone customer support.

6. Zvinotsanangurwa

FeatureTsanangudzo
BrandAiphone
Model NumberVM-RMVU
Simba VoltageAC100V: 50/60Hz
Kushandisa SimbaStandby 6W: Max 17W
Call MethodSimultaneous Call Method
Display7-inch TFT LCD Display (Touch Panel)
Nhamba yePixelsApprox. 1.15 miriyoni pixels
Wireless LANIEEE 802.11b/g/n (2.4GHz)
Zviyero zveChigadzirwa (LxWxH)18 x 22 x 4.5 cm
KuremaApprox. 880g
Kushanda Ambient Temperature0 kusvika 40°C
Inosanganisirwa ZvikamuChikwata chikuru

7. Warranty uye Tsigiro

For warranty information, technical support, or service inquiries, please refer to the official Aiphone website or contact your local Aiphone distributor. Keep your purchase receipt as proof of purchase.

Aiphone Official Websaiti: www.aiphone.com

Related Documents - VM-RMVU

Preview Aiphone JOW-2D Maviri Door Adapter yeJO Series Vhidhiyo Intercom System - Kuisa Gwaro
Mirayiridzo yakadzama uye zvakatemwa zveAiphone JOW-2D adapta, inogonesa maviri masuo zviteshi zveJO Series vhidhiyo intercom system. Dzidza nezve wiring, simba, uye maficha ekushandisa ekuisa intercom.
Preview Aiphone GT-1C Tenant Station Operation Guide
Yakakwana oparesheni gwara reAiphone GT-1C Tenant Station. Dzidza nezve simba rayo, LCD skrini, mutauri, maikorofoni, uye mabasa emabhatani akaita Door Release, Option, Guard, Talk, and Off, pamwe chete nedivi rekudzora kupenya, vhoriyamu, uye zoom.
Preview Aiphone AT-406/AT-306 Handset Intercom Installation uye Operation Manual
Yakadzama yekuisa uye yekushandisa bhuku reAiphone AT-406 Handset Intercom seti uye AT-306 sub chiteshi, inovhara sisitimu zvikamu, maficha, wiring, kukwira, mashandiro, tekinoroji yekudzivirira, yakatarwa, uye ruzivo rwewaranti.
Preview Bhuku rekushandisa reAiphone DB Series reKupindura Masuo Efoni Asina Mawaya Maviri
Gwaro rakakwana reAiphone DB Series rine mawaya maviri ekupindura masuo risina maoko, rinosanganisira maficha, zvikamu, waya, mapurogiramu, mashandiro, uye zvakatsanangurwa.
Preview Aiphone IX Series Master Station Operation Guide
A comprehensive operation guide for the Aiphone IX Series Master Station, detailing basic functions, button operations, and status indicators.
Preview Gwaro reKuronga Mapurogiramu reAiphone IXW-PBXA - Kutanga Nokukurumidza
Gwaro iri rinopa mirairo yekutanga nekukurumidza yekuronga hurongwa hweAiphone IXW-PBXA, ichisanganisira kuseta kwekutanga, gadziriso yekuwedzera, marongero etrunk, nzira dzekubuda, uye kugadzirisa matambudziko emasisitimu eintercom eIX|IXG Series.