Frigga U1

Frigga U1 Disposable Temperature Data Logger Instruction Manual

Muenzaniso: U1

1. Nhanganyaya

The Frigga U1 Disposable Temperature Data Logger is designed for reliable and accurate temperature monitoring during cold chain transportation and storage. This single-use device records temperature data over an extended period and generates automatic PDF and CSV reports upon connection to a computer, eliminating the need for specialized software or drivers.

Frigga U1 Disposable Temperature Data Logger

Image 1.1: The Frigga U1 Disposable Temperature Data Logger, showing its compact USB design.

2. Setup uye Operation

Follow these steps to set up and operate your Frigga U1 data logger:

2.1 Starting the Logger

  1. Dzvanya uye Bata: Locate the 'PRESS START STOP' button on the logger. Press and hold this button for more than 5 seconds.
  2. Simbiso The blue LED indicator will start to flash, indicating that the logger has successfully started recording.
  3. Siriyero nhamba: Tear off the serial number label for your reference and record-keeping.

2.2 Checking Logger Status

During operation, you can check the current status of the logger:

  • Press Button Briefly: Press the 'PRESS START STOP' button once.
  • Chiratidzo che LED: The LED indicators will flash to show the current status (e.g., recording, alarm status). Refer to the device's LED pattern guide for specific meanings.

2.3 Stopping the Logger

To stop the data logging process:

  1. Dzvanya uye Bata: Press and hold the 'PRESS START STOP' button for more than 5 seconds.
  2. Simbiso The red LED indicator will start to flash, confirming that the logger has successfully stopped recording.
  3. Kudzosa Data: After stopping, tear off the transparent plastic cover to expose the USB connector. Connect the logger to a USB port on a computer to retrieve the data.
Frigga U1 How to Use Diagram

Image 2.1: Diagram illustrating the start, status request, and stop procedures for the Frigga U1 data logger.

3. Kuwanikwa kweData uye Kushuma

The Frigga U1 logger automatically generates comprehensive reports without requiring any special software installation.

  1. Batanidza ku USB: Once logging is complete and the device is stopped, plug the logger into any standard USB 2.0 port on a computer (Windows or Mac).
  2. Automatic Report Generation: The device will automatically generate a PDF report and a CSV data file. Izvi files can be found in the removable drive that appears on your computer.
  3. Review Data: Open the PDF report for a summary, graph, and key statistics. The CSV file provides raw temperature data for detailed analysis.
Auto PDF Report Plug and Play

Image 3.1: Illustration of connecting the Frigga U1 to a computer to automatically generate PDF and CSV reports.

4. Key Features

  • Accurate Temperature Data: Equipped with an advanced internal sensor, providing a measuring range of -30°C to 70°C (-22°F to 158°F). Accuracy is ±0.5℃ (-20℃ to +40℃) and ±1℃ for other ranges. Note: The device currently supports Celsius degrees only.
  • Auto-Generated Reports: Directly produces PDF and CSV reports upon USB connection, requiring no software or driver installation.
  • LED Alarm Indicator: Features an LED alarm function that alerts users if the temperature exceeds pre-set thresholds, crucial for maintaining temperature stability.
  • Delayed Start Design: Includes a 30-minute time delay before logging begins. This prevents false alarms when the temperature is briefly outside the acceptable range during initial placement, protects the device, and conserves energy.
  • High Capacity: Capable of storing up to 28,800 data points, suitable for long-term monitoring up to 200 days.
  • IP68 Waterproof Giredhi: Designed to be highly resistant to water and dust, ensuring reliability in various environments.
Frigga U1 Single-Use Data Logger Features

Mufananidzo 4.1: Pamusoroview of the Frigga U1's features, including 200 days logging, LED indicator, press button, and USB 2.0 interface.

Frigga U1 User-friendly Interface and IP68 Waterproof

Image 4.2: Highlighting the user-friendly interface and IP68 waterproof rating of the Frigga U1.

5. Zvikumbiro

The Frigga U1 Disposable Temperature Data Logger is suitable for a variety of applications requiring precise temperature monitoring:

  • Cold-chain Transportation
  • Medicine Storage
  • Food Refrigeration
  • Greenhouse and Planting Environments
  • Environmental Testing
  • Commercial and Industrial Monitoring
Frigga U1 Applications

Mufananidzo 5.1: Anooneka examples of the Frigga U1's diverse applications in cold chain and environmental monitoring.

6. Zvinotsanangurwa

ParameterValue
Model NumberU1
Measurement Range-30°C ~ 70°C (-22°F ~ 158°F)
Accuracy Range±0.5℃ (-20℃ ~ +40℃); ±1℃ for other ranges
Memory CapacityMax 28800 readings
Log Nguva10 minutes (adjustable from 10s to 24h)
Tanga Kunonoka30 kwemaminitsi
Report FormatPDF & CSV (inogadzirwa otomatiki)
InterfaceUSB 2.0
Waterproof GiredhiIP68
DimensionsZvinenge 2.95 x 1.22 inches
Frigga U1 Product Parameters

Image 6.1: Detailed product parameters and dimensions of the Frigga U1 data logger.

7. Kugadzirisa matambudziko

  • Logger Not Starting: Ensure you press and hold the 'PRESS START STOP' button for more than 5 seconds until the blue LED flashes. If it still doesn't start, the device might be faulty or its battery depleted.
  • Logger Not Stopping Manually: While the manual stop button is designed to work, some units may require connection to a computer to finalize the stop process and generate reports. If the red LED does not flash after holding the button, connect the logger to a computer to ensure data is saved and the logging process is terminated.
  • No Report Generated After USB Connection:
    • Ensure the logger was properly stopped (red LED flashed).
    • Edza kubatanidza kune imwe USB port kana imwe komputa.
    • Check if the computer recognizes the device as a removable drive. If not, the USB connection might be faulty.
  • Kuverenga Kusina Kurongeka: Ensure the logger is placed in an environment where air circulation is adequate and not directly exposed to extreme localized heat or cold sources that do not represent the overall environment.

8. Kuchengeta

The Frigga U1 is a disposable device and requires minimal maintenance. Keep the USB connector clean and dry before use. Store unused loggers in a cool, dry place away from direct sunlight.

9. Warranty uye Tsigiro

Each Frigga U1 Disposable Temperature Data Logger comes with a warranty. Please refer to the warranty card included in your package for specific terms and conditions.

  • User Manual: Scan the QR code on the warranty card to access the digital user manual.
  • Calibration Certificate: Connect the logger to your computer to export the calibration certificate.
  • Tsigiro yehunyanzvi: For any problems or inquiries, please contact our 24/7 Technician Support via email. Contact details are available on the warranty card or the official Frigga website.

Related Documents - U1

Preview Frigga T7 Series User Manual - Real-Time Cold Chain Temperature Monitoring
Comprehensive user manual for the Frigga T7 Series temperature data logger. Covers device appearance, display functions, setup, monitoring, stopping, reporting, and important cautions for cold chain logistics.
Preview FRIGGA V5 Tembiricha uye Humidity Data Logger Mushandisi Manual
Chinyorwa chemushandisi cheFRIGGA V5 Temperature uye Humidity Data Logger, inotsanangura maficha ayo, mashandiro, kuseta, uye kuzivisa mabasa einotonhora cheni zvinhu.
Preview Frigga Data Center Mushandisi Manual V 1.0.0
Yakazara mushandisi bhuku reFrigga Data Center software, inotungamira vashandisi kuburikidza nekuisa, manejimendi data, kumisikidzwa kwechishandiso, makore masevhisi, uye maficha ekuteerera ekutonhora cheni yekutarisa.
Preview FRIGGA V5 Plus Series Tembiricha & Humidity Data Logger Mushandisi Manual
Yakakwana mushandisi bhuku reFRIGGA V5 Plus Series tembiricha uye humidity data logger. Dzidza maitiro ekumisikidza, kushanda, uye kudzoreredza data kubva kune yako logger yekutonhora cheni yekutarisa.
Preview Frigga 4G & Wi-Fi 6 Chaiyo-Nguva Multisensor Mushandisi Manual
Chinyorwa chemushandisi cheFrigga 4G & Wi-Fi 6 Chaiyo-Nguva Multisensor (Modhi S0), inotsanangura maficha ayo, zvirimo pasuru, chigadzirwa pamusoro.view, mirairo yekuseta, gwara rechiratidzo che LED, ruzivo rwehunyanzvi, kuiswa kwechishandiso, ruzivo rwebhatiri, matanho ekugadzirisa matambudziko, uye kutevedzera FCC.
Preview Frigga SV2 Series Smart Active Data Logger User Manual
User manual for the Frigga SV2 Series Smart Active Data Logger, detailing appearance, display functions, operation steps, usage scenarios, and FCC compliance.