SEAFLO SFDP2-018-120-31

Bhuku rekushandisa reSEAFLO 24V 1.8 GPM 120 PSI 31-Series DC Diaphragm Pombi

Muenzaniso: SFDP2-018-120-31

1. Nhanganyaya

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your SEAFLO 31-Series 24V DC Diaphragm Pump. This pump is designed for high-pressure applications, delivering a consistent flow rate suitable for RV water systems, marine use, agricultural spraying, and various cleaning tasks. Please read these instructions thoroughly before installation and use.

SEAFLO 31-Series DC Diaphragm Pump, side view with fittings

Figure 1: SEAFLO 31-Series DC Diaphragm Pump with included fittings.

2. Safety Information

  • Kuchengetedzwa Kwemagetsi: Ita shuwa kuti magetsi anoenderana nekuwanda kwepombitage (24V DC). Disconnect power before performing any installation or maintenance. All wiring should be performed by a qualified individual and comply with local electrical codes.
  • Kudzvinyirira Mvura: This pump operates at high pressure (120 PSI). Ensure all connections and plumbing are rated for this pressure to prevent leaks or bursts.
  • Temperature Limits: Do not exceed the maximum fluid temperature of 140°F (60°C).
  • Zvinwiwa zvinopisa: Do not pump flammable liquids. This pump is designed for water and non-corrosive, non-flammable fluids only.
  • Kufefetedza Ensure adequate ventilation around the pump to prevent overheating.
  • Kudzivirira Kweziso: Always wear appropriate eye protection when working with plumbing systems and power tools.

3. Zvigadzirwa zveChigadzirwa

  • High-Pressure Performance: Delivers 1.8 GPM flow rate with a 120 PSI shut-off pressure.
  • Self-Priming: Capable of self-priming up to 6 feet (1.8m) suction lift.
  • Run-Dry Safe: Designed to prevent damage if the water supply runs low.
  • Automatic Pressure Switch: Built-in switch automatically starts and stops the pump based on demand.
  • Quiet Operation: Engineered for low noise and vibration.
  • Durable Construction: Features EPDM valves and a Santoprene diaphragm for extended lifespan in harsh environments.
  • Zvishandiso Zvakasiyana-siyana: Suitable for RVs, boats, agriculture, and cleaning systems.

4. Zvinotsanangurwa

TsanangudzoValue
ModelSFDP2-018-120-31
Voltage24V DC
Flow Rate1.8 GPM (7.0 LPM)
Kudzvanywa Kwakavharika120 PSI (8.3 BAR)
Max Dhirowa6.0A
Priming Unyanzvi6 feet (1.8m) suction lift
Max Tembiricha140°F (60°C)
Ports3/8"-18 FNPT
Product Dimensions8.3"L x 3.3"W x 4.5"H
Item Weight4.2 Pondo
SEAFLO 31-Series DC Diaphragm Pump, side view ine chitaridzo chezvinotsanangurwa

Figure 2: Pump label showing model and electrical specifications.

5. Setup uye Kuiswa

  1. Kukwidza: Select a dry, well-ventilated location for mounting the pump. The pump can be mounted horizontally or vertically. Secure the pump using the integrated mounting feet. Ensure the mounting surface is stable and can support the pump's weight and vibration during operation.
  2. Plumbing Connections:
    • Connect the inlet side of the pump to your water source. The pump is self-priming up to 6 feet, but placing it as close to the water source as possible is recommended.
    • Connect the outlet side of the pump to your distribution system. Use appropriate 3/8"-18 FNPT fittings and ensure all connections are tight to prevent leaks, especially given the high operating pressure.
    • Consider installing a filter on the inlet side to protect the pump from debris.
    • A flexible hose connection is recommended to reduce vibration and noise.
  3. Electrical Wiring:
    • Ensure the power supply is 24V DC.
    • Connect the positive (+) wire from the power source to the positive (+) terminal on the pump.
    • Connect the negative (-) wire from the power source to the negative (-) terminal on the pump.
    • Install an appropriate fuse (not included) in the positive line, close to the power source, to protect the pump and wiring. Refer to the specifications for maximum current draw (6.0A).
    • Iva nechokwadi chekuti zvese zvinobatanidzwa nemagetsi zvakachengeteka uye zvakachengetedzwa kubva kuunyoro.
SEAFLO 31-Series DC Diaphragm Pump, bottom view showing mounting feet and connections

Mufananidzo 3: Pazasi view of the pump, illustrating mounting points and port locations.

6. Operating Instructions

  1. Kutanga kwekutanga:
    • Ensure all plumbing connections are secure and the inlet line is submerged in water.
    • Open a faucet or outlet downstream from the pump to allow air to escape the system.
    • Apply power to the pump. The pump will begin to prime and push water through the system.
    • Once a steady stream of water flows from the open outlet and all air is purged, close the outlet. The pump's automatic pressure switch will detect the pressure build-up and shut off.
  2. Normal Operation: The pump is designed for on-demand operation. It will automatically turn on when a faucet or outlet is opened (pressure drops) and turn off when all outlets are closed (pressure builds up to 120 PSI).
  3. Run-Dry Protection: The pump is designed to run dry without damage. However, continuous dry running is not recommended and can lead to premature wear. Ensure a consistent water supply.

7. Kuchengeta

  • Kugara Kuongorora: Nguva nenguva tarisa zvese zvakabatana nemapombi nemagetsi kuti uone kana zvakabata uye zviratidzo zvekusakara kana ngura.
  • Inlet Sefa: If an inlet filter is installed, clean it regularly to prevent clogging and maintain optimal flow.
  • Winterization (for cold climates): If the pump is installed in an environment where freezing temperatures may occur, it must be drained or winterized with non-toxic antifreeze to prevent damage. Disconnect inlet and outlet lines and allow water to drain completely, or flush with RV/marine antifreeze.
  • Kuchenesa Pombi: Chenesa kunze kwepombi uchishandisa chizivisoamp cloth. Do not use harsh chemicals or immerse the pump in water.

8. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
Pombi haibatike.Hapana magetsi, fuse yakaputika, waya dzakasununguka, switch isina kunaka.Tarisa magetsi, tsiva fuse, simbisa kubatana, uye edza switch.
Pump runs but no water flows.No water in supply, air leak on inlet side, clogged inlet filter, pump not primed.Check water source, inspect inlet connections, clean filter, re-prime pump.
Low flow or low pressure.Clogged inlet filter, restricted plumbing, low voltage, worn pump head.Clean filter, check for kinks/blockages, verify voltage, inspect pump head.
Pump cycles on and off rapidly.Small leak in system, faulty pressure switch, insufficient accumulator tank (if installed).Check for leaks, test/replace pressure switch, consider accumulator tank.
Ruzha rwakanyanya kana kudedera.Loose mounting, air in system, debris in pump, worn bearings.Secure mounting, purge air, check for debris, contact support if internal issue.

9. Warranty uye Tsigiro

The SEAFLO 31-Series DC Diaphragm Pump is backed by a 4-makore waranti kubva pazuva rekutenga. Iyi waranti inovhara kukanganisa mune zvigadzirwa uye kugadzirwa pasi pekushandiswa kwakajairwa uye sevhisi.

For warranty claims, technical assistance, or replacement parts, please contact SEAFLO customer support. Keep your purchase receipt as proof of purchase.

Contact Information: Please refer to the SEAFLO official webwebhusaiti kana kurongedza chigadzirwa chako kuti uwane ruzivo rwemazuva ano rwerutsigiro rwevatengi.

Related Documents - SFDP2-018-120-31

Preview SEAFLO 31 & 35 Series Diaphragm Pump Manual
Bhuku rakazara reSEAFLO 31 uye 35 Series Diaphragm Mapombi, rinofukidza matambudziko, maficha, maapplication, kuisirwa, ruzivo rwemagetsi, uye kugadzirisa kits. Gwaro iri rinopa mirairo yakadzama yekushanda kwakanyanya uye kugadzirisa.
Preview SEAFLO 22 Series Diaphragm Pump Manual
Bhuku rekushandisa rakakwana reSEAFLO 22 Series Diaphragm Pump, rinosanganisira kugadzirisa, kugadzirisa matambudziko, uye mashandisirwo ekugadzirisa mvura zvakanaka.
Preview SEAFLO 33 Series Diaphragm Pump Manual
Bhuku rino rinopa ruzivo rwakadzama pamusoro pekuiswa, kushanda, kugadzirisa matambudziko, nekugadzirisa kweSEAFLO 33 Series Diaphragm Pump, pombi yepamusoro, yepamusoro-soro inokodzera kushandiswa kwakasiyana-siyana zvinosanganisira maRV, yachts, uye masisitimu emvura.
Preview SEAFLO Diaphragm Pump Manual - 52 & 54 Series
Yakakwana bhuku reSEAFLO 52 uye 54 Series diaphragm pombi, inovhara maficha, maapplication, kuisirwa, ruzivo rwemagetsi, kugadzirisa kits, uye kugadzirisa matambudziko. Inosanganisira mirairo yakadzama uye zvidziviriro zvekuchengetedza.
Preview SEAFLO Electric Field Bilge Switch Instruction Manual
Chinyorwa chekuraira cheSEAFLO Electric Field Bilge Switch (SFBS-20-06), inotsanangura kugadzirisa, kuisirwa, wiring, kuyedzwa, uye mashandisirwo e12/24V DC mapombi ebilge muzvikepe zvekunakidzwa.
Preview Bhuku rekushandisa reSEAFLO SFMP-120-01 Macerator Pombi 01 Series
Bhuku rekushandisa reSEAFLO SFMP-120-01 Macerator Pump 01 Series. Rinopa ruzivo nezvezvikamu, magadzirirwo, mapombi, kubatana kwemagetsi, uye kugadziriswa kwezvishandiso zvemugungwa neRV.