RAB Lighting B17

RAB Lighting B17 LED Bollard Light Instruction Manual

Muenzaniso: B17

1. Nhanganyaya

This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting B17 LED Bollard Light. This outdoor luminaire features field-adjustable wattage and selectable color temperature (CCT), designed for various outdoor applications.

Zvinhu zvakakosha zvinosanganisira:

RAB Lighting B17 LED Bollard Light

Figure 1: RAB Lighting B17 LED Bollard Light (Model B17D shown).

2. Safety Information

YAMBIRO: Risk of electric shock. Disconnect power before installation or servicing. Installation should be performed by a qualified electrician in accordance with all applicable national and local electrical codes.

3. Package Zviri mukati

Tarisa kuti zvese zviriko zviripo usati watanga kuisa:

4. Setup uye Kuiswa

Follow these steps for proper installation of the B17 LED Bollard Light:

  1. Gadzirira Saiti yekuisa: Ensure the mounting surface is stable and level. Run electrical conduit and wiring to the desired location according to local codes.
  2. Bvisa Simba: Dzima magetsi pa circuit breaker usati watanga chero basa remagetsi.
  3. Mount the Bollard: Secure the bollard base to the mounting surface using appropriate hardware. Ensure a watertight seal if required by local codes.
  4. Gadzira Mabatiro eMagetsi: Connect the fixture's wires to the supply wires. Follow standard wiring practices:
    • Black to Line (L)
    • White to Neutral (N)
    • Green/Ground to Ground (G)
    • Purple to Dimming (+) (for 0-10V dimming)
    • Gray to Dimming (-) (for 0-10V dimming)
    Ita shuwa kuti zvese zvinongedzo zvakachengeteka uye zvakavharirwa.
  5. Sarudza Wattage uye CCT: Before closing the fixture, adjust the wattage and CCT switches located inside the fixture head. Refer to Section 5 for details.
  6. Secure the Fixture Head: Attach the fixture head to the bollard body, ensuring all seals are properly seated to maintain the wet location rating.
  7. Dzosera Simba: Turn on power at the circuit breaker and test the light.
UL Listed and Wet Location Rated symbols

Figure 2: The B17 Bollard Light is UL Listed and rated for wet locations, ensuring durability in outdoor environments.

5. Operating Instructions

5.1. Field-Adjustable Wattage

The B17 bollard light allows you to select the desired wattage output to optimize brightness and energy consumption. A switch located inside the fixture head enables selection between 24W, 19W, and 14W.

Kugadzirisa: Disconnect power. Open the fixture head. Locate the wattage selection switch and move it to the desired setting. Close the fixture head and restore power.

5.2. Selectable Color Temperature (CCT)

The fixture offers three color temperature options to suit different aesthetic preferences and applications. A separate switch inside the fixture head allows selection between 3000K, 4000K, and 5000K.

Kugadzirisa: Disconnect power. Open the fixture head. Locate the CCT selection switch and move it to the desired setting. Close the fixture head and restore power.

Image showing 14W, 19W, 24W wattage options and 3000K, 4000K, 5000K CCT options for the bollard light

Figure 3: Visual representation of adjustable wattage and selectable CCT settings.

5.3. 0-10V Dimming

The B17 bollard light is compatible with 0-10V dimming systems. Connect the purple and gray dimming wires to a compatible 0-10V dimmer control. This allows for smooth adjustment of light output from 100% down to 10% (or lower, depending on dimmer specifications).

Ensure the dimmer is rated for LED loads and is compatible with 0-10V dimming protocols.

6. Kuchengeta

The B17 LED Bollard Light is designed for minimal maintenance due to its long LED lifespan of 50,000 hours.

Image indicating a 50,000-hour lifespan for the LED bollard light

Figure 4: The B17 LED Bollard Light offers a long 50,000-hour operational lifespan.

7. Kugadzirisa matambudziko

DambudzikoZvinogona KukonzeraSolution
Chiedza hachibatidze.Hapana magetsi.
Loose wiring connection.
Wat isiriyotage/CCT setting.
Check circuit breaker. Ensure power is on.
Verify all wire connections are secure (power off first).
Confirm wattage/CCT switches are set correctly.
Chiedza chinopenya kana kudzima zvisingatarisirwi.Dimmer isingaenderani.
Loose dimming wire connection.
Voltage fluctuations.
Ensure 0-10V dimmer is compatible with LED loads.
Check purple and gray dimming wire connections.
Bvunza nyanzvi yemagetsi kuti uone kugadzikana kwemagetsi.
Chiedza chinobuda chakaderera/chakakwirira.Wat isiriyotage kumisikidza.Gadzirisa wattage selection switch inside the fixture head (power off first).
Light color is not desired.Kurongeka kweCCT kusina kururama.Adjust the CCT selection switch inside the fixture head (power off first).

8. Zvinotsanangurwa

FeatureDetail
Model NameB17
BrandRAB Lighting
WattageField-Adjustable: 24W / 19W / 14W
Kupisa Kwemavara (CCT)Selectable: 3000K / 4000K / 5000K
Dimming0-10V Dimmable
Hupenyu hurefu50,000 maawa
MaterialMetal body, Glass shade
Environmental RatingUL Listed for Wet Locations
Inosanganisirwa ZvikamuOn-Off Chinja
UPC192552028424
ASINB0DY2FPPNS

9. Warranty uye Tsigiro

For warranty information and technical support, please contact RAB Lighting directly. Refer to the official RAB Lighting webwebhusaiti kana magwaro ako ekutenga kuti uwane mamwe mashoko ewarandi uye ruzivo rwekuonana.

RAB Lighting Contact: www.rablighting.com