Product Overview
This manual provides essential information for the safe and efficient operation of your Euker 5000 BTU Window Air Conditioner. Please read all instructions carefully before installation and use.

Mufananidzo: Mberi view of the Euker 5000 BTU Window Air Conditioner, showcasing its compact design and mechanical controls.
Setup uye Installation
Your Euker 5000 BTU Window Air Conditioner is designed for easy installation in standard double-hung windows. The unit includes all necessary mounting accessories.
Window Zvinodiwa:
- Window Width: 23 inches to 34 inches
- Minimum Window Height: 14.5 inches
Kuisa Matanho (Zvose):
- Bvisa air conditioner nezvimwe zvese zvinoshandiswa.
- Batanidza mapaneru epadivi kune mudziyo.
- Place the unit into the window opening, ensuring it is securely seated.
- Extend the side panels to fill the window gap and secure them.
- Install the support brackets and debris guards as instructed in the detailed user manual.
- Apply window seal foam to prevent air leakage.

Image: Components of the easy installation kit, including the remote control, top foam sealer, bubble level, and support brackets, alongside the air conditioner unit with its dimensions for window fitting.
Operating Instruction
The Euker 5000 BTU Window Air Conditioner features user-friendly mechanical controls for simple operation.
Control Panel:
The unit is equipped with two rotary knobs:
- Tembiricha Knob: Adjusts the cooling intensity with 7 distinct settings.
- Modhi Knob: Selects between cooling and fan-only operations, and fan speeds.

Mufananidzo: Kuvhara view of the air conditioner's mechanical control panel, showing the temperature and mode selection knobs.
Air Direction:
The air vents can be manually adjusted to direct airflow in two directions, allowing for customized cooling distribution within the room.
Maitiro Okushandisa:
- Mamiriro Akanaka Provides active cooling to lower room temperature.
- Fan Mode: Circulates air without cooling, useful for ventilation.
- Nzira yekurara: Operates at a reduced noise level (approximately 40dB) for quiet overnight comfort. This mode often adjusts temperature gradually to maintain comfort while saving energy.

Image: Illustration of the air conditioner's sleep mode, showing a gradual temperature adjustment over an 8-hour period for quiet and comfortable sleep, with a noise level of 40dB.
Noise Level:
The unit incorporates SilenceWrap™ Technology in its compressor design, resulting in a quiet operation with noise levels typically below 50dB, ensuring minimal disturbance.

Image: Diagram illustrating the SilenceWrap™ Technology compressor, highlighting features like shock absorption and self-evaporation, contributing to a noise level below 50dB.
Maintenance
Kugara kugadziridza kunovimbisa kuita kwakaringana uye hupenyu hurefu hwemhepo yako conditioner.
Sefa Kuchenesa:
The air conditioner features a removable, washable filter for easy maintenance. Cleaning the filter regularly helps maintain air quality and cooling efficiency.
- Gently pull the front handle to remove the filter.
- Geza sefa nemvura inodziya, ine sipo. Sukurudza zvakakwana.
- Rega firita iome zvachose usati waisazve.
- Slide the dry filter back into its position until it clicks securely.

Image: A visual guide demonstrating the removal and cleaning of the detachable filter, showing it being rinsed under a faucet.
General Cleaning:
Pukuta kunze kweyuniti nekanyoro, damp jira. Usashandise makemikari ane hasha kana abrasive cleaners.
Kugadzirisa matambudziko
If you encounter issues with your air conditioner, refer to the following common problems and solutions:
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Unit haibatike | No power, tripped circuit breaker, loose plug | Tarisa magetsi, gadzirisa chinokanganisa magetsi, iva nechokwadi chekuti plug yakachengeteka. |
| Kusakwana kutonhora | Dirty air filter, blocked air intake/outlet, room too large, window not sealed | Clean filter, clear obstructions, ensure proper room size, seal window gaps. |
| Noise yakanyanyisa | Loose parts, unit not level, fan obstruction | Check for loose components, ensure unit is level, remove any fan obstructions. |
| Kubuda kwemvura | Unit not level, drain plug blocked | Ensure unit is slightly tilted outwards for drainage, check and clear drain plug. |
For issues not listed here, or if problems persist, please contact customer support.
Zvinotsanangurwa
Key technical specifications for the Euker 5000 BTU Window Air Conditioner (Model 5K-MC):
| Feature | Detail |
|---|---|
| Brand | Euker |
| Model Number | 5K-MC |
| Cooling Capacity | 5000 BTU |
| Yakakurudzirwa Saizi Yekamuri | Kusvika 150 sq.ft |
| Magetsi | 115V/60Hz |
| Control Type | Mechanical Knob |
| Tembiricha Settings | 7 inogadziriswa |
| Fan Speeds | 2 |
| Air Direction | 2-Nzira Inogadziriswa |
| Noise Level | 50 dB (yakajairika) |
| Rudzi rwesefa | Inobviswa, Inogezwa |
| Item Weight | 41.4 makirogiramu |
| Zviyero zveChigadzirwa (D x W x H) | 17.91 x 14.84 x 15.04 inches |
| Special Features | Fast Cooling, Auto Restart |

Image: Visual representation of the air conditioner's powerful cooling performance, indicating its ability to cool areas up to 150 square feet with 5000 BTU cooling efficiency.

Image: Comparison showing the Euker 5000 BTU unit's 25% energy saving, with a CEER rating of 12.0 compared to a traditional window AC's 8.0 CEER.

Image: Illustration detailing the efficiency of the 12W DC Motor, claiming 40% more air volume, 40% less noise distractions, and 80% more energy saving.
Warranty Information
For detailed warranty information, please refer to the warranty card included with your product or contact Euker customer support. Protection plans may also be available for extended coverage.
Mutengi Support
If you require assistance, have questions, or need to report a problem, please contact Euker customer support through the official websaiti kana ruzivo rwekusangana rwunopihwa mune yako chigadzirwa kurongedza.
Kuti uwane zviwanikwa zvepaindaneti, shanyira Euker Store on Amazon.