1. Nhanganyaya
Thank you for choosing the KAIWEETS KC200D Digital Clamp Meter. This device is a compact, high-precision instrument designed for electrical measurements in various settings, including home, commercial, and industrial environments. It features True RMS technology for accurate readings of complex waveforms, Non-Contact Voltage (NCV) detection for enhanced safety, and a clear backlit LCD for easy readability. This manual provides essential information for safe and effective use of your clamp mita.
2. Safety Information
To ensure safe operation, please read and understand all safety warnings and operating instructions before using this instrument. Failure to observe these warnings can result in serious injury or death.
- Gara uchiomerera kumakodhi ekuchengetedza emunharaunda uye enyika.
- Usashandise mita kana ikaita seyakakuvara kana kuti kana chinhu chinodzivirira kupisa chiri pamatambo ekuyedza chisina kunaka.
- Usashandise zvinopfuura zvakatemerwa voltage, as marked on the meter, between terminals or between any terminal and ground. The maximum operating voltage 600V.
- Shandisa kungwarira zvakanyanya paunenge uchishanda nevoltages above 60V DC or 30V AC RMS. These voltages inokonzeresa njodzi.
- Keep your fingers behind the finger guards on the test leads during use.
- Usashandise mita munzvimbo dzine gasi rinoputika, utsi, kana guruva.
- Remove the test leads from the circuit before changing functions.
- Always turn off the power to the circuit under test before connecting or disconnecting the test leads.
- Iva nechokwadi chekuti chifukidziro chebhatiri chakavharwa zvakanaka usati washandisa mita.
3. Package Zviri mukati
Verify that all items listed below are present and undamaged:
- 1 x KAIWEETS KC200D Digital Clamp Meter
- 1 x Chinyorwa cheMushandisi
- 1 x Kuchengeta Bhegi
- 2 x Bvunzo dzeKuedza (Dzvuku neDema)
- 2 x AAA 1.5V Mabhatiri
4. Chigadzirwa Pamusoroview
The KAIWEETS KC200D is designed for ease of use and durability. Familiarize yourself with the main components:

Mufananidzo 4.1: KAIWEETS KC200D Clamp Meter with its various measurement functions highlighted, including AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency, Diode Test, Continuity, and NCV.
4.1 Zvikamu Zvikuru
- Clamp Rushaya: Inoshandiswa pakuyera magetsi eAC/DC asingabatanidzi simba.
- Basa Dial: Rotary switch to select measurement modes.
- Chiratidziro cheLCD: Inoratidza kuverengwa kwekuyera, mayuniti, uye zviratidzo.
- Mabhatani: For special functions like Data Hold, MAX/MIN, DC Zero, Backlight, and NCV.
- Input Terminals: Yekubatanidza bvunzo inotungamira yevoltage, resistance, capacitance, frequency, diode, and continuity measurements.
5. Setup
5.1 Kuiswa kwebhatiri
The KC200D requires two AAA 1.5V batteries (included).
- Iva nechokwadi chekuti mita yadzimwa.
- Tsvaga nzvimbo yebhatiri kuseri kwemamita.
- Shandisa screwdriver kuvhura chivharo chebhatiri.
- Insert the two AAA batteries, observing the correct polarity (+ and -).
- Tsiva chivharo chekamuri yebhatiri uye chengetedza nescuru.
5.2 Kubatanidza Miedzo Inotungamira
For measurements requiring test leads (voltage, resistance, capacitance, frequency, diode, continuity):
- Insert the red test lead into the "INPUT" terminal.
- Insert the black test lead into the "COM" (Common) terminal.
6. Operating Instructions
Always select the appropriate function before making any measurement. Turn the function dial to the desired measurement mode.
6.1 AC/DC Chiyero Chazvino (Clamp)
Shandisa clamp jaw for non-contact current measurement. This method is ideal for safely measuring current without breaking the circuit.

Mufananidzo 6.1: Iyo clamp jaw of the KC200D measuring current on a single electrical wire, demonstrating its compact design and precision.
- Shandura iyo dial yekushanda kune iyo 20A~ or 200A~ position for AC current, or 20A= or 200A= for DC current.
- Dzvanya clamp trigger to open the jaw.
- Encircle only Poshi conductor with the clamp jaw. Do not clamp around multiple wires, as this will result in an inaccurate reading.
- For DC current measurement, press the Z/F button to zero the display before clamping.
- Verenga kukosha kwazvino paLCD kuratidza.
6.2 AC/DC Voltage Kuyera
Kuyera voltage, use the test leads.
- Shandura iyo dial yekushanda kune iyo V~ (AC Voltage) kana V= (DC Voltage) chinzvimbo.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side (or ground).
- Verenga bhukutage kukosha pane LCD kuratidza.
6.3 Resistance Kuyera
Ita shuwa kuti dunhu rabviswa simba risati rayera kuramba.
- Shandura iyo dial yekushanda kune iyo Ω chinzvimbo.
- Batanidza bvunzo dzinotungamira mukati mechikamu kuti kuyerwa.
- Verenga kukosha kwekupikisa pane LCD kuratidza.
6.4 Kuyera Kwemagetsi
Discharge capacitors completely before measurement to avoid damage to the meter or injury.
- Shandura iyo dial yekushanda kune iyo Capacitance position (often shared with Diode/Continuity, press FUNC to cycle).
- Batanidza matambo ekuyedza nepakati pe capacitor.
- Verenga iyo capacitance kukosha paLCD kuratidza.
6.5 Frequency Kuyera
Kuyera frequency:
- Shandura iyo dial yekushanda kune iyo Hz% chinzvimbo.
- Connect the test leads across the circuit where frequency is to be measured.
- Verenga frequency kukosha paLCD kuratidza.
6.6 Bvunzo yeDiode
Ita shuwa kuti diode yakabviswa kubva kudunhu.
- Shandura iyo dial yekushanda kune iyo Diode position (often shared with Capacitance/Continuity, press FUNC to cycle).
- Connect the red test lead to the anode and the black test lead to the cathode.
- A forward voltage drop will be displayed for a good diode. Reverse the leads; the display should show OL (Open Loop).
6.7 Kuenderera mberi Muedzo
Iva nechokwadi chekuti dunhu harina simba.
- Shandura iyo dial yekushanda kune iyo Continuity position (often shared with Diode/Capacitance, press FUNC to cycle).
- Batanidza matambo ekuyedza pachikamu kana waya.
- If there is continuity (low resistance), the meter will emit an audible beep.
6.8 Vasina-Kubata Voltage (NCV) Kuonekwa
The NCV function allows for quick and safe detection of live AC voltage pasina kuonana kwakananga.

Mufananidzo 6.2: The KC200D performing Non-Contact Voltage (NCV) detection near an electrical outlet, showing visual indicators for low and high voltage kuvapo.
- Shandura iyo dial yekushanda kune iyo NCV chinzvimbo.
- Bring the top end of the meter near the conductor or outlet.
- The meter will emit an audible beep and illuminate LED indicators, with frequency increasing as voltagSimba rinowedzera.
6.9 Mabasa Akakosha

Mufananidzo 6.3: The KC200D highlighting its user-friendly functions: MAX for peak value, Z/F for DC current zeroing, H for data hold, backlight for low-light conditions, and auto-off for battery saving.
- Data Hold (H/* button): Dzvanya kuti uomese kuverenga kuripo pachiratidziro. Dzvanya zvakare kuti ubvise.
- MAX/MIN (MAX button): Press to display the maximum or minimum measured value. Press again to cycle.
- DC Current Zero (Z/F button): For DC current measurements, press this button before clamping to zero out any residual readings.
- Backlight (H/* long press): Long press the H/* button to turn the display backlight ON or OFF for improved visibility in low-light conditions.
- Auto-Off: The meter automatically powers off after approximately 15 minutes of inactivity to conserve battery life. Press any button or rotate the function dial to wake it up.
7. Kuchengeta
7.1 Kuchenesa
Pukuta mita nejira rakaoma uye rakapfava. Usashandise zvinogumbura kana zvinonyungudutsa.
7.2 Kutsiviwa kwebhatiri
When the battery indicator appears on the LCD, replace the batteries as described in the Setup section (5.1 Battery Installation).
7.3 Kuchengeta
If the meter is not used for an extended period, remove the batteries to prevent leakage and damage. Store the meter in its carrying bag in a cool, dry place.
8. Kugadzirisa matambudziko
| Dambudziko | Zvinogona Kukonzera | Solution |
|---|---|---|
| Meter haina simba | Dead batteries; Incorrect battery installation | Tsiva mabhatiri; Tarisa polarity yebhatiri |
| Inaccurate current reading | Multiple conductors in clamp jaw; DC current not zeroed | Ensure only one conductor is clamped; Press Z/F button for DC current |
| "OL" displayed (Overload) | Measurement exceeds range; Open circuit (for continuity/resistance) | Select a higher range (if available); Check circuit connections |
| Hapana kuonekwa kweNCV | Hapana AC voltage present; Meter not close enough to source | Verify AC voltage presence; Move meter closer to the live conductor |
9. Zvinotsanangurwa
Technical specifications for the KAIWEETS KC200D Digital Clamp Meter:
| Feature | Tsanangudzo |
|---|---|
| Model Number | KC200D |
| Display | Makonti 2000, LCD ine mwenje wekumashure |
| AC Yazvino | 20A/200A (±(2.5% + 5 digits)) |
| DC Nhasi | 20A/200A (±(2.5% + 5 digits)) |
| AC Voltage | 2V/20V/200V/600V (±(1.0% + 5 digits)) |
| DC Voltage | 200mV/2V/20V/200V/600V (±(0.5% + 5 digits)) |
| Resistance | 200Ω/2kΩ/20kΩ/200kΩ/2MΩ/20MΩ (±(1.0% + 5 digits)) |
| Capacitance | 2nF/20nF/200nF/2µF/20µF/200µF/2mF/20mF (±(4.0% + 5 digits)) |
| Frequency | 2Hz/20Hz/200Hz/2kHz/20kHz/200kHz/2MHz/20MHz (±(1.0% + 3 digits)) |
| Diode Bvunzo | Ehe |
| Continuity Test | Ehe |
| Kuonekwa kweNCV | Ehe |
| Magetsi | 2 x AAA 1.5V Mabhatiri |
| Safety Rating | CAT III 600V, Pollution Level: 2 |
| Dimensions | 20.7 x 11.3 x 4.7 cm (Package) |
| Kurema | 308 grams (Package) |
10. Warranty uye Tsigiro
KAIWEETS products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact information provided on the KAIWEETS official website or contact your local distributor. Please retain your purchase receipt as proof of purchase for warranty claims.