Cannex-logo

Cannex Technology F-101 Wireless Remote Controller

Cannex-Technology-F-101-Wireless-Remote-Controller-chigadzirwa

F-101 Temperature Controller Panel Zvinyorwa

  • Zviyero: 16.5 × 5 × 1.4 cm
  • Set Temp Range : 15°C–35°C (59°F–95°F)
  • Timer Range: 1-24 maawa (kuratidza yakavanzwa kana yaiswa ku0 awa)
  • Infrared Effective Linear Distance : 6–8 m (inosiyana zvishoma nenharaunda)
  • Zvishandiso
  • °C/°F Kuchinja : Shandura kuburikidza nebhodhi redunhu remukati (kuseri kwerikure) kana Bata mabhatani ese eTemp +/- panguva imwe chete kwemasekonzi gumi mushure mekuisa simba.
  • Modes: Kutonhora-chete / Kupisa-Kunotonhorera / Kuwedzera kwakananga (yakaderera ikozvino, yakakwirira ikozvino, 25A)
  • Wire-Yemahara Yekubatanidza: Pakati pekudzora bhokisi uye kure.

F-101

Wireless Remote Controller

F-101 Remote Controller Operation Guide

  • Kutanga Kuisa Battery (RESET State)
    Kana mabhatiri akaiswa kekutanga, ese maLCD segment anovhenekera kwemasekonzi mashanu kuti aone kushanda kwekuratidzira.
  • Operation Mode → Kutonhodza (Kutonhorera)
  • Seta Tembiricha → 26°C
  • Kumhanya kweFan → Auto
  • Basa Rekurara → Kudzima
  • Airflow Direction → Haisi kutsigirwa (yemhando dzechiller unit)
  • Basa renguva → Yakaremara (0 awa)

Operation Mode Sarudzo

  • Dzvanya bhatani re "Mode" kutenderera kuburikidza nemamodhi
    Kutonhodza (Kutonhorera) Fani (Ventilation) Kupisa (Kupisa)
  • Kugadzirisa Tembiricha (SET TEMP):
  • MuKutonhodza (Kutonhorera) Modhi
    Dzvanya ▲/▼ kugadzirisa tembiricha (range : 15°C–35 °C).
  • MuHot Mode
    Dzvanya ▲/▼ kugadzirisa tembiricha (15°C–35°C)
  • MuFan mode
    Kudzora tembiricha kwakadzimwa (host relay inoramba AKADZIMWA)

Fan Speed ​​​​Setting 

  • Dzvanya bhatani re "Fan Speed" kutenderera kuburikidza:
    Yakakwirira (HI), Medium (MED), Yakaderera (LO), Auto (AUTO)
  • Basa Rekurara (KURARA):
  • Yekushandisa panguva yekurara
  • Mune Kutonhorera / Kupisa maitiro
  • Dzvanya zvakare kudzima Kurara basa
  • Air Direction Setting (OSC.) :
    Haipo (yechiller unit modhi) (Yakafukidzwa nemazita)
  • Kuseta Auto-Off Timer (TIMER) :
    Panguva iyo unit iri ON :
    Dzvanya bhatani re "Timer" (▲/▼) kuseta yaunoda OFF nguva
  • Kuisa Auto-On Timer (TIMER) :
    Ipo yuniti YAKAZIMA: Dzvanya bhatani re "Timer" (▲/▼) kuseta yaunoda PANE nguva.
  • Simba Pa / Kudzima (SIMBA Pa / Kudzima) :
  • Dzvanya bhatani re "Operation / Stop" kuti ubatidze
  • Dzvanya zvakare uchiri ON kuti DZIMA
  • Kana yabatidzwa, tambira RELAY→Batidza

Receiver Indicator Light Status

  1. Simba-pakusimbisa → Chiedza chebhuruu chinopenya katatu & mwenje wegirini unoramba wakabatidzwa (unodzima mushure memasekondi mashanu)
  2. Chiedza chebhuruu chinoramba chiripo → Vhuru yemvura Yakabatidzwa panguva yekushanda
  3. Chiedza chebhuruu chinononoka kupenya (10s kubviswa / 0.4s pa) → Mvura vharuvhu Inodzima panguva yekushanda (inoshanda sechiratidzo chesimba)
  4. Bhuruu chiedza chinokurumidza kupenya → Chimiro chisina kujairika
  5. Chiedza chegirini → Nyaradzo yekurara modhi
  6. Mwenje dzvuku → Simba rakarongwa pa/kudzima
  7. Chiedza cheOrenji → Modhi yekurara + yakarongwa magetsi kudzimwa
  8. Pakugamuchira chiratidzo kubva kure controller → Buzzer inonzwika kamwe muchidimbu

Cherechedza

  1. Tsvuku inoratidza kugadzirisa
  2. Iyo yakavakirwa-mukati tembiricha sensor mune ino inogamuchira inofanirwa kuiswa padhuze nekudzoka kwemhepo vent kana munzvimbo ine mhepo inofefetera.

Air Conditioning Mabasa

Cooling Mode

  1. Nzira nhatu dzeValve Operation
  2. Tembiricha yemumba ≥ Set tembiricha → nzira nhatu vharafu On
  3. Tembiricha yemumba ≤ (Set tembiricha -1°C) → Thr ee-way valve Off
  4. Vatatu-nzira vharafu ine 1-miniti kunonoka kutanga kudzivirira

Feni Kushanda

Manual Fan Mode : 3-kumhanya kugadziridza (Pamusoro/Pakati/Pazasi)

Auto Fan Modhi muKutonhodza 

  1. Tembiricha yemumba ≤ Seta tembiricha → Yakaderera
  2. Set tembiricha < Room tembiricha < (Set tembiricha +4°C) → Pakati
  3. Tembiricha yemumba ≥ (Set tembiricha +4°C) → Yakakwirira

Heating Mode

Nzira nhatu dzeValve Operation

  1. Tembiricha yemumba ≤ Seta tembiricha → nzira nhatu vharafu Pa
  2. Tembiricha yemumba ≥ Set tembiricha +1°C → Three-way valve Off
  3. Vatatu-nzira vharafu ine 1-miniti kunonoka kutanga kudzivirira
  4. Feni Kushanda
    Manual Fan Mode : 3-kumhanya kugadziridza (Pamusoro/Pakati/Pazasi)

Auto Fan Mode muKupisa 

  1. Seta tembiricha ≤ Tembiricha yemumba → Yakaderera
  2. Tembiricha yekamuri < Set tembiricha < Room tempe rature +4°C → Medium
  3. Seta tembiricha ≥ Tembiricha yemumba +4°C → Yakakwirira

Extended Models

  • Yakananga Kuwedzera Air Conditioner Special Type (Okuwedzera Mabasa):
  • Matatu-nzira vharafu ine 3-maminetsi kunonoka kutanga kudzivirira (Inogona kuve yakashongedzerwa nepamusoro-ikozvino RELAY yeCompressor control)
  • Mhepo inotungamira louver (OSC.) kuisirwa: Inodzora main unit RELAY → ON/OFF semhepo inotungamira basa

E-mail : sales@akr.com.tw http://www.akr.com.tw

Zvinyorwa / Zvishandiso

Cannex Technology F-101 Wireless Remote Controller [pdf] User Manual
F-101 Wireless Remote Controller, F-101, Wireless Remote Controller, Remote Controller, Controller

References

Siya mhinduro

Yako email kero haizoburitswa. Nzvimbo dzinodiwa dzakamakwa *